    2350 Mis sio n C ollege Blv d. Suite 600 Santa Clar a, CA 95 05 4 www .bladene twork.n et BLADEO S ™ Release Notes 1/10Gb U plink E thernet Switch Mod ule for IBM BladeCe nter ® Ve r s i o n 5 . 1 Part N umber: BM D00098, D ecember 2009 ...

  • Blade ICE BMD00098 - page 2

    BLADE OS 5.1 Release Notes 2 BMD00098 , Decem ber 200 9 Copyrigh t © 200 9 BLADE Network T echnologies, Inc., 2350 Mi ssion Coll ege Blv d. Suite 600, Sa nta Clara, Californi a, 95054, USA. Al l rights reserved. Reference number: BM D00098 This do cument is p rotec ted by co pyright a nd dist ributed un der lic enses re strictin g its u se, copyin ...

  • Blade ICE BMD00098 - page 3

    BMD00098 , Decem ber 200 9 3 Release Notes The 1/10G b Uplink Ether net Switch Module (GbES M) is on e of up t o four Gb ESMs that ca n be installed in the IBM BladeC enter chassis . These releas e no tes pr ovi d e th e lates t infor mat ion r egardin g BL ADEOS 5.1 for the 1/ 10Gb Up lin k Ethernet Switch Module. This supplement modifies informat ...

  • Blade ICE BMD00098 - page 4

    BLADE OS 5.1 Release Notes 4 BMD00098 , December 2009 Hardwa re Support BLADEOS 5 .1 software is sup ported only o n the 1/10G b Uplink Ethernet Switch Mo dule ( Figure 1 ) for IBM BladeCenter . The GbESM is a high perfor mance Layer 2-3 embedded network switch that features tight integration with IBM BladeCenter management modules. Figure 1 1/10G ...

  • Blade ICE BMD00098 - page 5

    BLADE OS 5.1 Rel ease Notes BMD00098 , December 200 9 5 The GbESM contains three 10 Gigabit Small Form-factor , Pluggable (SFP+) slots. The 10Gb SFP+ slots can accept 1Gb copper transceivers, 10Gb optical transceivers, or Direct Attach Cables (DAC). Note – If a DAC is not p rogrammed to m eet MSA sp ecifications (including length identifier), the ...

  • Blade ICE BMD00098 - page 6

    BLADE OS 5.1 Release Notes 6 BMD00098 , December 2009 Up da ting the Swi tch Sof t ware Imag e The switch software image i s the executab l e code running on the GbESM. A version o f the image ships with the switch, and comes pre-installed on the dev i ce. As new ver sions of the image ar e released, you can upgrade the soft ware runni ng on your s ...

  • Blade ICE BMD00098 - page 7

    BLADE OS 5.1 Rel ease Notes BMD00098 , December 200 9 7 Using the BLADEOS CL I 1. At the Boot Options# prom pt , ent er: 2. Enter the name of the s wit ch software to be r eplaced: 3. Enter the hostname o r IP address of the FTP or TFTP server . 4. Enter the name of the new software file o n the server . The exact form of the name will vary by serv ...

  • Blade ICE BMD00098 - page 8

    BLADE OS 5.1 Release Notes 8 BMD00098 , December 2009 Using the ISCLI 1. In Privileged EXEC mode, enter the following command: 2. Enter the hostname o r IP address of the FTP or TFTP server . 3. Enter the name of the new software file o n the server . The exact form of the name will vary by server . However , the file location is normally relative ...

  • Blade ICE BMD00098 - page 9

    BLADE OS 5.1 Rel ease Notes BMD00098 , December 200 9 9 Using the BBI Y ou can use the Browser-B ased Interface to load software onto the GbESM. Th e software image to load can resid e in one of the f o llowing locations:  FTP server  TFTP server  Local computer After you log onto the BBI, perform the followin g steps t o load a softwa re ...

  • Blade ICE BMD00098 - page 10

    BLADE OS 5.1 Release Notes 10 BMD00098 , December 2009 New and Up date d Features BLADEOS 5.1 for 1/10Gb Uplink Ethernet Switch Mod ule (GbESM) has been updated to include new and enhan ced features in support of s erver and peer switch discovery , as well as failure detection at the link layer . In addition, there are enhancements to exis tin g im ...

  • Blade ICE BMD00098 - page 11

    BLADE OS 5.1 Rel ease Notes BMD00098 , December 200 9 11 Uni-Directional L ink Discovery Protocol BLADEOS 5.1 now supports th e Uni-Directional Link Discovery (UDLD) protocol, compliant with RFC 51 71. UDLD operates at Layer 2 in co njunction with existing IEEE 802. 3 Layer 1 fault detection mechanisms. It is used between peer devices to detect and ...

  • Blade ICE BMD00098 - page 12

    BLADE OS 5.1 Release Notes 12 BMD00098 , December 2009 Internal Loopback Interfa ce BLADEOS 5.1 now supp orts up to f ive loopback interfaces . A loopback interface is an interface which is assigned an IP address, but is not associated with any particular phys ical port. The loop back interface is thus always ava i lable for higher layer pro tocols ...

  • Blade ICE BMD00098 - page 13

    BLADE OS 5.1 Rel ease Notes BMD00098 , December 200 9 13 Hot Links BLADEOS 5 .1 now supports Hot Lin ks. Hot Link s provides bas ic link redundancy with fa st recover y for netwo rk topologies th at requi re Spanning T ree to be turned o ff. Hot Links allows up to five triggers, each of which cons is ts of a pair of layer 2 interfaces that may cont ...

  • Blade ICE BMD00098 - page 14

    BLADE OS 5.1 Release Notes 14 BMD00098 , December 2009 LACP T runk Enhancem ent s BLADEOS 5 .1 now supp orts up to eight links in ea ch LACP Link Aggregat ion Grou p (LAG). Layer 2 Failover Enhancement s BLADEOS 5.1 includes multiple enhancements to the Layer 2 Failover feature to s upport advanced NIC teaming:  In addition to the automatic moni ...

  • Blade ICE BMD00098 - page 15

    BLADE OS 5.1 Rel ease Notes BMD00098 , December 200 9 15 ISL Layer 2 Protocol Enhancem ent s BLADEOS 5 .1 now supports add itional Layer 2 protocols on Inte r -Switc h Link (ISL) ports:  VRRP  STP  RSTP/MST P  802.1Q VLAN T aggi ng  802.1 p Qo S/CoS  802.1X Port-B ased Access Control  ACLs STP Fast Uplink Bridge P riority W ith ...

  • Blade ICE BMD00098 - page 16

    BLADE OS 5.1 Release Notes 16 BMD00098 , December 2009 Chassis Internal Network BLADEOS 5.1 now supp orts BladeCenter Chassi s Internal Network (CIN). CIN provides internal connectivity between b l ade server ports and the internal Advanced Manag ement Module (AMM) port. This allows blade server users to access the AMM via CLI, web-browser , or SNM ...

  • Blade ICE BMD00098 - page 17

    BLADE OS 5.1 Rel ease Notes BMD00098 , December 200 9 17  Port link information ( /info/link ) for swi tches installed i n bay 3 and bay 4 :  Port in form atio n ( /info/port ) for switches instal led in ba y 1 and bay 2: Alias Port Speed Duplex Flow Ctrl Link ---- ----- ----- -------- --TX-----RX-- ------ INT1 1 1000 full yes yes up INT2 2 1 ...

  • Blade ICE BMD00098 - page 18

    BLADE OS 5.1 Release Notes 18 BMD00098 , December 2009  Port in form atio n ( /info/port ) for switches instal led in ba y 3 and bay 4: Other Featur es BLADEOS 5 .1 now also support s  PVRST Alias Port Tag Fast Lrn Fld PVID NAME VLAN(s) ----- ---- --- ---- --- --- ---- -------------- -------------------- INT1 1 y n e e 1 INT1 1 4095 INT2 2 y ...

  • Blade ICE BMD00098 - page 19

    BLADE OS 5.1 Rel ease Notes BMD00098 , December 200 9 19 Supplement al In formation This section provides additional informatio n abo ut configu ring and operating the GbESM and BLADEO S. Management Module  The “Fast POST=Disabled/Enabled” insid e the IBM managemen t module W eb interface “I/O Module Adm in Power/Restart” d oes not apply ...

  • Blade ICE BMD00098 - page 20

    BLADE OS 5.1 Release Notes 20 BMD00098 , December 2009 Management Module/GbESM Connectivity Currently , the IBM management module is designed to provide one-way control of the GbESM. As a result, the GbESM may lose connectivity to the managem e nt module v ia the man agemen t port under the following conditions:  If new IP attributes are pushed ...

  • Blade ICE BMD00098 - page 21

    BLADE OS 5.1 Rel ease Notes BMD00098 , December 200 9 21 Secure Management Network The following GbESM attributes are reserved to p rovide secure m anagement access to and from the IBM managemen t mod ule: Internal management—  MG T1 (port 15) and MG T2 (port 16)  VLAN 4095  IP interface 128  Gateway 4  STG 128 For more information ...

  • Blade ICE BMD00098 - page 22

    BLADE OS 5.1 Release Notes 22 BMD00098 , December 2009 Sp a nnin g T ree Con figuration Tip s T o ensure proper operation with s w itches that use Cisc o Per VLAN Spanning T ree (PVST+), you mus t do one of the follo win g :  Create a separate Spanning T ree Group f or each VLAN.  Manually add all associated VLANs into a single Spann ing T r ...

  • Blade ICE BMD00098 - page 23

    BLADE OS 5.1 Rel ease Notes BMD00098 , December 200 9 23 Known issues The follo wing are known issues f or BLA DEO S 5. 1 on the 1/10Gb Upl ink Ethernet Switch Mod ule. Access Control List s  When an Access Contr o l List (ACL) is installed on two diff erent ports, only one statistics counter will be av ailabl e. Th e GbESM d oes no t su ppo rt ...

  • Blade ICE BMD00098 - page 24

    BLADE OS 5.1 Release Notes 24 BMD00098 , December 2009 Link Aggregation Control Prot ocol If a static trunk on a GbE SM is connected to ano ther GbESM with LACP configured (but no active LACP trunk), the /info/l2/trunk command migh t erroneously report the s tatic trunk as forwarding. Since LACP trunks use LACPDU packet to maintain trunking wit h t ...

  • Blade ICE BMD00098 - page 25

    BLADE OS 5.1 Rel ease Notes BMD00098 , December 200 9 25 RADIUS with SSHv2 W ith RADIUS tu rned on, users migh t see a duplicate login promp t for SSHv2 clients , if the RADIUS server is too slow to respond or if the R A DIUS server is not available. In this case, users must re-ty pe the user na me an d passw ord t o logi n. RIP MIBs Due to backwar ...

  • Blade ICE BMD00098 - page 26

    BLADE OS 5.1 Release Notes 26 BMD00098 , December 2009 St rong Password Expiration If you configure a S trong Password with automatic expiration, the passwo rd might not expire if the system d ate an d t ime is not config ured f irst. Use o f a N etwork T i me P rotocol (N TP) se rver r esolv es this issue. Solution: When you configure a strong pas ...

Produzent Blade ICE Kategorie Switch

Dokumente, die wir vom Produzenten des Geräts Blade ICE BMD00098 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Blade ICE
- Bedienungsanleitungen BMD00098
- Produktkarten Blade ICE
- Informationsbroschüren
- oder Energieetiketten Blade ICE BMD00098
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Blade ICE BMD00098.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Blade ICE BMD00098, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Blade ICE BMD00098. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Blade ICE BMD00098 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Blade ICE BMD00098, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Blade ICE BMD00098 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Blade ICE BMD00098 verständlich ist.

Eine gänzliche Bedienungsanleitung von Blade ICE sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Blade ICE BMD00098 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Blade ICE BMD00098 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Blade ICE BMD00098, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Blade ICE BMD00098 - die uns die ersten Schritte während der Nutzung von Blade ICE BMD00098 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Blade ICE BMD00098 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Blade ICE BMD00098 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Blade ICE BMD00098?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Blade ICE BMD00098 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Blade ICE BMD00098 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)