    FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC Canada, V4G 1H4 908-332b MODELS: H2100 I1 100S I3100L WOOD Fireplace Inserts & Hearth Heater 06/02/06 Owners & Installation Manual T ested by: Installer : Please complete the details on the back cover and leave this manual with the homeowner . Homeowner: Please keep th ...

  • Regency H2100 - page 2

    Regency Wood Insert & Hearth Heater 2 Thank-you for purchasing a REGENCY FIREPLACE PRODUCT . The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area. Keep those ...

  • Regency H2100 - page 3

    Regency Wood Insert & Hearth Heater 3 REGENCY FIREPLACE INSERTS & HEARTH HEA TER T ABLE OF CONTENTS SAFETY LABEL Safety Label For I1 100S & I3100L ................................. 4 Safety Label For H2100M ............................................. 5 INST ALLA TION Before Installing Y our Insert ..................................... ...

  • Regency H2100 - page 4

    Regency Wood Insert & Hearth Heater 4 LISTED FACTORY BUILT FIREPLACE INSERT CERTIFIED FOR USE IN CANADA AND U.S.A. MODEL: I3100L TESTED TO: ULC S628-M93 / UL 1482-1998 / ULC S627-00 / UL 737-2000 REPORT NO. 632-323500 (MAR.1994) DO NOT REMOVE THIS LABEL 106 COMPONENTS REQUIRED FOR INSTALLATION: 6" (150mm) STAINLESS STEEL LINER. OPTIONAL CO ...

  • Regency H2100 - page 5

    Regency Wood Insert & Hearth Heater 5 SAFETY LABEL This is a copy of the label that accompanies each Regency Hearth Heater . We have printed a copy of the contents here for your review . 103 DO NOT REMOVE BRICKS OR MORTAR IN MASONRY FIREPLACE. FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEART ...

  • Regency H2100 - page 6

    Regency Wood Insert & Hearth Heater 6 INST ALLA TION CHIMNEY SPECIFICA TIONS Before installing, check and clean your chimney system thoroughly . If in doubt about its condi- tion, seek professional advice. Y our Regency Insert is designed for installation into a masonry fi replace that is constructed in accordance with the requirements of &quo ...

  • Regency H2100 - page 7

    Regency Wood Insert & Hearth Heater 7 Clearance diagram for installations INST ALLA TION Side and T op facing is a maximum of 1.5" thick. Floor protection must non-combustible, insula- tive material with an R value of 1.1 or greater . * If the hearth extension is fl ush with the fl oor (F) it must extend 19.5" in front of the body f ...

  • Regency H2100 - page 8

    Regency Wood Insert & Hearth Heater 8 1) Positive Flue Connection with Cleanout FLUE CONNECT OR BRACKET Package contains: 3 brackets and 6 screws. These brackets are to be used to hold the fl ue liner (not supplied) to the Insert and keep the connection. The brackets are screwed into the top of the Insert in the pre-punched holes and then scre ...

  • Regency H2100 - page 9

    Regency Wood Insert & Hearth Heater 9 INST ALLA TION Diagram 4: H2100M and I3100L Faceplate Assembly B) H2100M and I3100L Insert Diagram 2: I1 100S Rear View Diagram 3: I1 100S 1) Slide the spring nuts (supplied) over the slots in the insert’s side convection panels (the spring nuts may need to be squeezed with a pair of pliers fi rst, to he ...

  • Regency H2100 - page 10

    Regency Wood Insert & Hearth Heater 10 Ground Fan Fan Ground Green Neutral Live White Fan Switch Manual/ Auto Switch Black Black High (Black) Low (Red) Black Fan Thermodisc (normally open) 120V AC 60 Hz Thermo Switch Sensor Thermo Switch Sensor INST ALLA TION F AN / BLOWER Blower/Fan Wiring Diagram 3) Slide the supports into the clips. The tens ...

  • Regency H2100 - page 11

    Regency Wood Insert & Hearth Heater 11 BRICK FLUE BAFFLE & SECONDAR Y AIR TUBE INST ALLA TION The fl ue baffl e system located in the upper area of the fi rebox is removable to make cleaning your chimney system easier . The brick baffl es must be installed prior to your fi rst fi re. Smoke spillage and draft problems may occur if the ...

  • Regency H2100 - page 12

    Regency Wood Insert & Hearth Heater 12 Pull Open Push Closed INST ALLA TION Side View Front View Front View Hearth Heater (H2100M) Steel Baffl e Place the insulation batt on top of the baffl e. Make sure that this batt is laying fl at and does not obstruct the smoke from getting up the fl ue opening. This insulating batt may be wrapped in p ...

  • Regency H2100 - page 13

    Regency Wood Insert & Hearth Heater 13 automatic temperature sensor will engage the blower when the unit is at temperature and will shut off the blower once the fi re has gone out and the unit has cooled to below a useful heat output range. T o manually operate the fan system, push the fi rst switch to "Man" and second switch to eit ...

  • Regency H2100 - page 14

    Regency Wood Insert & Hearth Heater 14 6) Do not permit creosote or soot buildup in the chimney system. Check and clean chimney at regular intervals. 7) Y our Regency Insert can be very hot. Y ou may be seriously burned if you touch the insert while it is operating. W arn children of the burn hazard. 8) The insert consumes air while operating, ...

  • Regency H2100 - page 15

    Regency Wood Insert & Hearth Heater 15 I1 100 & I3100 MAIN ASSEMBL Y Part # Description 846-913 Door Assembly-Small Gold (I1 100)-no glass 846-915 Door Assembly-Small Black (I1 100)-no glass 846-910 Door Assembly-Large Gold (I3100)-no glass 846-916 Door Assembly-Large Black (I3100)-no glass 2) 846-302 Glass - Replacement - (I1 100) 3) 846-3 ...

  • Regency H2100 - page 16

    Regency Wood Insert & Hearth Heater 16 P ARTS LIST I1 100 & I3100 F ACEPLA TES Part # Description Faceplate: I3100L 163-910 Faceplate & T rim Set - Regular 385) 163-165 T rim Right Regular 386) 163-160 T rim T op Regular 387) 163-161 T rim Left Regular 388) * Faceplate Side Regular 389) * Faceplate T op Regular 163-912 Faceplate & T ...

  • Regency H2100 - page 17

    Regency Wood Insert & Hearth Heater 17 H2100 MAIN ASSEMBL Y Part # Description Part # Description 1) 846-910 Door Assembly-Large Gold - no glass 846-916 Door Assembly-Large Black - no glass 3) 846-304 Glass - Replacement 4) 936-243 7/8" Adhesive T ape Gasket 5) 846-920 Glass Retainer Clips (set of 8) 6) * Screw 1/4-20 x 3/8" 7) 948-17 ...

  • Regency H2100 - page 18

    Regency Wood Insert & Hearth Heater 18 P ARTS LIST I1 100, I3100 & H2100 FIREBRICK Part # Description 70) 902-1 1 1 Brick Regular Full Size: 1-1/4" x 4-1/2" x 9" 71) 802-104 Brick Partial: 1-1/4" x 4" x 9" 72) 802-146 Brick Partial: 1-1/4" x 1-3/4" x 9" 75) 802-139 Brick Partial: 1-1/4" x 4& ...

  • Regency H2100 - page 19

    Regency Wood Insert & Hearth Heater 19 W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T e am carefully inspects each unit thoroughly before it leaves our door . Regency Industries Ltd. is pleased to extend this limited lifetime warranty to the original purch ...

  • Regency H2100 - page 20

    Printed in Canada Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: _________________________________________________________ ...

Produzent Regency Kategorie Indoor Fireplace

Dokumente, die wir vom Produzenten des Geräts Regency H2100 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Regency
- Bedienungsanleitungen H2100
- Produktkarten Regency
- Informationsbroschüren
- oder Energieetiketten Regency H2100
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Regency H2100.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Regency H2100, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Regency H2100. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Regency H2100 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Regency H2100, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Regency H2100 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Regency H2100 verständlich ist.

Eine gänzliche Bedienungsanleitung von Regency sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Regency H2100 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Regency H2100 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Regency H2100, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Regency H2100 - die uns die ersten Schritte während der Nutzung von Regency H2100 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Regency H2100 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Regency H2100 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Regency H2100?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Regency H2100 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Regency H2100 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)