Stovax 7129 - page 1
Stockton 8 Integral Boiler Stove MODEL: 7129 Installation and Operating Instructions F or Use in Great Britain and Eire IMPORT ANT Please read these instructions carefully before using the appliance. Keep them safe for future reference and when servicing the stove. PM140-Issue 1 (April 2005) This product is suitable for use in the stated countries. ...
-
Stovax 7129 - page 2
2 FOR Y OUR RECORDS T o assist us in any Guarantee claim please complete the following information:- Stovax dealer appliance was purchased from Name: ...................................................................................................................... Address: ........................................................................ ...
-
Stovax 7129 - page 3
3 PRE-INST ALLA TION CHECKS Before installation of this product please read these instructions fully . It is very important to also understand the requirements of the UK Building Regulations (England and W ales – Document J / Scotland - P art F), along with any local regulations that may apply . Should any conflict occur between these instruction ...
-
Stovax 7129 - page 4
4 PRE-INST ALLA TION CHECKS Check that the Flue or Chimney is structurally sound. In particular , it should not be possible for products of combustion to come into contact with combustible materials in the structure of the building . Check the flue draught. This should be done with all windows and doors closed and any extraction fans in adjoining r ...
-
Stovax 7129 - page 5
5 INST ALLA TION 3. HEA TING CIRCUIT All water heating installations should be designed, before product installation, and installed by a competent heating engineer in conjunction with the requirements detailed in the following: The Building Regulations The Local W ater Authority Bylaws IEE Wiring Regulations BS 5449: 1 Any other relevant Local Auth ...
-
Stovax 7129 - page 6
6 INST ALLA TION Hot water An allowance should be made in any calculation for the heat requirement for any hot water tank fitted to the system. Pipe losses Consideration should be given heat loses through the pipework used in the heating circuit. ...
-
Stovax 7129 - page 7
7 INST ALLA TION Because each installation is unique to the property , it is not possible to give full details of the constructional hearth setting . However , this should be constructed to comply with the requirements of the Building Regulations and be made using “ best practice” construction methods. Remember that many fireplace openings will ...
-
Stovax 7129 - page 8
8 INST ALLA TION 2.7 The system vent should be a minimum diameter of 22mm and fitted with an air separation device. 2.8 The Heat Sink (Slumber circuit) must be rated to suit the minimum heat output at slow running , and have no manual or automatic closing valves fitted. 2.9 Thermostatic flow controls (90°C flow and 55°C return) should be fitted t ...
-
Stovax 7129 - page 9
9 INST ALLA TION 3. COMMISSIONING 3.1 Check there are no leaks in the water system and all internal parts are correctly fitted, all seals are undamaged and the air controls and door catch are operating freely . The fit of the door may be adjusted if required by moving the hinge blocks. This may be done by loosening the hinge clamping nuts, and re-t ...
-
Stovax 7129 - page 10
10 OPERA TING INSTRUCTIONS Caution! P arts of the Stockton stove are manufactured from cast iron, which needs to be tempered before the stove is operated at the highest temperatures. Therefore it is recommended that the stove is operated at low temperatures for the first 24 hours of use. During this time the appliance may give off some unpleasant o ...
-
Stovax 7129 - page 11
11 OPERA TING INSTRUCTIONS Solid Fuel 1.1 Using solid fuel. 1.2 Open the Airwash air control to approximately 50% open and Primary air control fully . See diagram 1. 1.3 Place some pieces of firelighters or dry crumpled paper on the grate and cover with some small pieces of dry kindling wood. Light the paper or firelighters. Do not burn plastics. 1 ...
-
Stovax 7129 - page 12
12 OPERA TING INSTRUCTIONS 1.4 As the fire becomes established add larger pieces of wood and close the Primary air control and control the burn rate using the Airwash air control only . 1.5 T o burn wood efficiently it is best to allow a bed od ash to build-up on the grate, and continue to control the combustion using the Airwash air control only . ...
-
Stovax 7129 - page 13
13 OPERA TING INSTRUCTIONS 3. ASH REMOV AL 3.1 The burning of any fuel will produce ash, which will have to be removed after a period of use. This time will depend on the fuel used. Before removing the ash from the appliance it is advisable to let the fire burn down to a low level, or even go out completely . 3.2 The ashpan can then be removed from ...
-
Stovax 7129 - page 14
14 MAINTENANCE 1.GENERAL CLEANING 1.1 W e would recommend that your Stockton stove be cleaned fully on a regular basis, according to the level of use. Attention should be given to cleaning the flueways and removing ash. Regular cleaning and preventive maintenance will help give many years of safe use. 2. CLEANING GLASS 2.1 While the correct use of ...
-
Stovax 7129 - page 15
15 MAINTENANCE 4.4 Clean the internal surfaces of the appliance using a wire brush and scraper as required. V acuum and brush the resulting debris from the stove then give the inside of the appliance a protective coating of light oil, such as WD40®. 4.5 Clean the Grate parts with a wire brush, and check the parts for any damage. Replace any damage ...
-
Stovax 7129 - page 16
16 MAINTENANCE 5. RECOMMENDED FUELS W ood:- Burn only seasoned timber , with a moisture content of less than 20%. In most cases this would require drying cut wood for 12 to 18 months before use. P oor quality timber could cause low combustion efficiency , produce large amounts of harmful condensation, which could reduce the effectiveness of the air ...
-
Stovax 7129 - page 17
MAINTENANCE 6. STOV AX STOVECARE PRODUCTS The following products, all available from your local Stovax stove stockist, will help you to keep your stove in the best possible condition. T ask P roduct name Stovax code number Glass cleaning Stove glass cleaner (500ml wipe- on) 4111 Stove glass cleaner (500ml spray-on) 4103 Preventing the Protector (15 ...
-
Stovax 7129 - page 18
18 ...
-
Stovax 7129 - page 19
19 ...
-
Stovax 7129 - page 20
Stovax Ltd, F alcon Road, Sowton Industrial Estate, Exeter , Devon, England EX2 7LF T el: (01392) 474011 F ax: (01392) 219932 E-mail: info@stovax.com www .stovax.com ...
Haben Sie eine Frage bezüglich Stovax 7129?
Nutzen Sie das untere Formular
Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Stovax 7129 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Stovax 7129 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.