  • Emerson 185 - page 1

    381333–319 E 50 Hanove r Road, F lorham Park, New J ersey 07932–1591 USA For sales or service call 1 800 800–2726 (A SCO ) www.ascopower .com AS CO PO WER TECH NO LOGI E S CA NA DA PO Box 1238, 17 Airport R oad, Brantf ord, O ntario, Can ada N 3T 5T3 Operator’s Manual Seri es 185 Automatic T ransfer S witc hes 100 th roug h 400 am pe re s i ...

  • Emerson 185 - page 2

    Seri es 185 381333–319 E Namepl ate The T rans fer Switch nam epla te incl udes data for each sp ecific A SCO S eries 185 A TS. Use th e A TS only wit hin the limits show n on this namep late. Ca talog Num ber Identif icatio n A typ ica l Ca ta lo g Numbe r i s s hown be l ow wi th i ts elements ex plained . Th e example is fo r a D–desig n, 2 ...

  • Emerson 185 - page 3

    INST ALLA TION Series 185 1 381333–319 E Instal lation of the ASCO Series 18 5 automatic transfer switc h (A TS) m ust be perfor med by a lic ensed elec trician. It m ust be in stall ed ac cor ding to t he Nation al El ectr ical Code (NEC) and all l ocal el ectric al code requirem ents. R emove the enclosure c over and i nspect the A TS for shipp ...

  • Emerson 185 - page 4

    CONT ROLLER Seri es 185 2 381333–319 E The Gr oup 4 dig ital Con trol ler is us ed in A SCO Ser ies 185 autom atic transfer sw itches. It provides the sensing , timing, a nd control functions for the A TS. T his micro– processor–based control ler includes buil t–i n control buttons and sta tus lights for control of the A T S and generator. ...

  • Emerson 185 - page 5

    CONT ROLLER Series 185 (continued) 3 381333–319 E 3 - - - Generator Starting Contacts The generat or starti ng contacts connections are on t he controller. R efe r to the generato r manual. Disconnect the ge nerator b attery and ve rify that the ig nition sw itch is in the OF F position. Connec t the gen erator startin g wires to t he appropri at ...

  • Emerson 185 - page 6

    Seri es 185 CONT ROLLER (cont inued) 4 381333–319 E S2 DIP switch S1 DIP switch Fi gure 6. DIP switches S1 and S2 at the top right. The ti me delay setti ngs are shown in Figures 6 and 7 and in T able C. The se nsor setti ngs are shown in Figure 6 and in T abl e D. The standard ( factory) settin gs are s h o w ni nT a b l e sC ,D , a n dH . S3 DI ...

  • Emerson 185 - page 7

    CONT ROLLER Series 185 (continued) 5 381333–319 E 6 - - - Remote Contro l & Load Disconnect These remote c ontrol feat ures r equire a custom er– sup pli e d no rma lly– clos ed co nt act s ui t able f o r a 5 V dc lo w energ y circ uit. R efer to the wiring d iagram p rovid ed w i t ht h eA T S . A c t i v a t et h ea p p r o p r i a t e ...

  • Emerson 185 - page 8

    FU N CTIO NA L TE ST Seri es 185 6 381333–319 E After ins talling the Series 18 5 automatic tr ansfer sw itch (A TS) perfor m the follow ing three–par t func tional test. 1 --- M a n u a l O p e r a t i o n A handle is provided on t he transfer swit ch for maintena nce purposes only. M a n u a l o p e r a t i on of t h e transfer s witch shou l ...

  • Emerson 185 - page 9

    Sequence of Operat ion - - - Utilit y Failur e Seri es 185 7 381333–319 E wait 10 se c. for generator to warm up generator runs unloaded for 2 min. generato r starting Ut ility fails (longe r tha n 3s e c . ) generato r stops wait 5 min. for util ity to st abilize obser ve these power lights obser ve these swi tch lights waiting for ut ility to r ...

  • Emerson 185 - page 10

    TR OUBLESHOOTING Seri es 185 8 381333–319 E This troubleshooting g uide describes some of the simple caus es of probl ems with the instal lation of the automatic transfer switch. T roubleshooting beyond the scope of this gu ide sho uld n ot be attem pted b y the instal le r. A lic ens ed elec trician must perform all internal tr oubl eshooting. A ...

  • Emerson 185 - page 11

    TR OUBLESHOOTING Series 185 (continued) 9 381333–319 E Probl em Cause a nd Sol ution The A TS does not im mediatel y transfer th e load to the generator. 1. V erify that the Generator Acceptable l ight is o n. If it is off, see pr eviou s trou bl e- shooting probl em. T he A TS will not transfer the load to an unac ceptable sourc e. 2. W ai t app ...

  • Emerson 185 - page 12

    INDEX Seri es 185 Printed in U .S.A. Copy right - - - ASCO Power T echn ologies, L.P . 2011 10 381333–319 E A A utomatic Gen erator Exer ciser, 2, 3, 9 B b a t t e r y ,c l o c k ,3 buttons, push, 2 Bypass T ime Del ay, button, 2 , 6 C cable s pa cer s, 1 cat alo g nu mber, in si de cov er cl ock batter y, 3 connections elec trical pow er, 1 engi ...

Produzent Emerson Kategorie Switch

Dokumente, die wir vom Produzenten des Geräts Emerson 185 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Emerson
- Bedienungsanleitungen 185
- Produktkarten Emerson
- Informationsbroschüren
- oder Energieetiketten Emerson 185
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Emerson 185.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Emerson 185, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Emerson 185. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Emerson 185 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Emerson 185, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Emerson 185 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Emerson 185 verständlich ist.

Eine gänzliche Bedienungsanleitung von Emerson sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Emerson 185 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Emerson 185 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Emerson 185, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Emerson 185 - die uns die ersten Schritte während der Nutzung von Emerson 185 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Emerson 185 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Emerson 185 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Emerson 185?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Emerson 185 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Emerson 185 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)