Bedienungsanleitung Bradford White EFTM

48 Seiten 1.7 mb
Download

Zur Seite of 48

Summary
  • Bradford White EFTM - page 1

    Internet Version for Reference Only ULTRA HIGH EFFICIENCY COMMERCIAL GAS WATER HEATER (EF™ Series Models) - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance - WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any ph ...

  • Bradford White EFTM - page 2

    Internet Version for Reference Only SECTION I: IMPO RTANT INFORMATION n j ur y hazards. Indicates an imminently hazardous situation, which, if not avoided, will result in death, serious injury or subs tantial property damage . DANGER Indicates potentially hazard ous situation, which, if not avoi ded, may result in moderate or minor injury or pr ope ...

  • Bradford White EFTM - page 3

    Internet Version for Reference Only DANGER DO NOT sto re or use gas oline or ot her flam mable, com bustible, or c orrosive v apors and/ or liquids i n the vicini ty of this or any other appliance. DO NOT instal l any damaged ve nting syst em com ponents. If dam age is evident then please contact the supplier where the water heater was purchased or ...

  • Bradford White EFTM - page 4

    Internet Version for Reference Only WARNING This water he ater needs fres h air for safe operation an d must be inst alled so there are provisio ns for adequat e combustion and ventilatio n air. Insufficient air supply w ill cause a recirculation of co mbustion products resultin g in contamination that may be hazardous to life. This will result in ...

  • Bradford White EFTM - page 5

    Internet Version for Reference Only SECTION II: SPECIFICATIONS Figure 1. Dimensional Layout Recovery GPH At Degree Rise DIMENSIONS ( INCHES ) Model No. Input Rate BTU/h 1st Hr. Del. Gal. At 100°F Rise 40°F 100°F 140°F Stg. Cap. U.S. Gal. Therm. Eff. % A Ht. B Dia. C Flr to Vent Outlet D Flr to Inlet Wtr. Conn E Flr to T&P Valve Conn F Fl. t ...

  • Bradford White EFTM - page 6

    Internet Version for Reference Only SECTION III: GENERAL INFORMATION FEATURES This water heater contains t he following feat ures: MAIN POWER O N/OFF SWITCH – The front panel of this wat er heater has a lighted ON/OFF switch, which is illuminated when the main power is turned on to indicate power to the water heater. COMBUSTION SYSTEM – This wa ...

  • Bradford White EFTM - page 7

    Internet Version for Reference Only TEMPERATURE AN D PRE SSURE RELIEF VALVE – pu s no ! CONDENSA TE DRAIN - The water heater should either be raised several inches above the floor on a concrete slab or use a low profile conden sate pump to allow free drainage of condens ate from the elbow drain fitting. This water heater is a condensing type unit ...

  • Bradford White EFTM - page 8

    Internet Version for Reference Only Figure 2. Condensa te Elbow Wi th Trap CLEANOUT – All models are equipped with a cleanout opening to aid in removal of hard water deposits from the tank bottom. If this water heater operates under hard water conditions, the following should be performed at least ev ery 3 months: Turn off water supply and d rain ...

  • Bradford White EFTM - page 9

    Internet Version for Reference Only SECTION IV: INSTALLATION INSTRUCTIONS This water heater must be located in an area where leaka g e of the tank, water line connections, or the combination temperatu re and pressure relief valve will not result in damage to the ar ea ad j acent to the water heater or to low er floors of the structure. When such lo ...

  • Bradford White EFTM - page 10

    Internet Version for Reference Only UNPACKING INSPECT SHIPME NT carefully f or any signs of dama ge. 1. All equ ipment is carefully manu factured, inspected and pac ked. 2. Any cl aims for damage or sh ortage in s hipment m ust be filed im mediat ely with Brad ford White C orporation and noted on t he Bill of La ding. 3. Remove all venting com pone ...

  • Bradford White EFTM - page 11

    Internet Version for Reference Only Figure 3b. Recommended Minimum Clearances For Service Access REMOVE CRATE 1. Remove all banding an d pry of f crate sides carefully so as not to dam age the water heater. 2. Carefu lly roll/lift the water heater from the crate base. CAUTION Do not drop wat er heater. Do not bum p water heater jacke t against floo ...

  • Bradford White EFTM - page 12

    Internet Version for Reference Only DANGER Temperature setting shoul d not exceed safe temperatur e at fixtures. See water tem perature control warning on page 1 6. If higher pre heat temperat ures are necessary to obtain adequate booster ou tput, add an anti-scald valve for hot water supplied to fixtures. LOCATION KEEP APPLIANCE AREA CLEAR AND FRE ...

  • Bradford White EFTM - page 13

    Internet Version for Reference Only 3. If the water heater is installed as a direct vent (outsi de air piped directly to the water heater), then addition al opening, other than the op ening for the air intake, are no t required. However, adequate ventilatio n air must be provided in all cases to preven t increased room temperature. CHEMICAL VAPOR C ...

  • Bradford White EFTM - page 14

    Internet Version for Reference Only Figure 6. Typical Two Water Heater Connection Figure 7. Typical Three Water Heate r Connection Figure 8. Typical Four Water Heater Connection 14 ...

  • Bradford White EFTM - page 15

    Internet Version for Reference Only SECTION V: WA TER CONNECTIONS WARNING Failure to install and maintain a new, listed temperature an d pressure relief valve will release the manufactu rer from any claim, which might res ult from ex cessive temperature and press ures. Hydrogen gas can be produced i n an operati ng water heater t hat has not had wa ...

  • Bradford White EFTM - page 16

    Internet Version for Reference Only The following chart details the relationship of water temperature and time with regard to scald injury an d may be used as a guide in determinin g the safest water temperature for your app lications. Approximate Time/Temperature Scald Chart APPROXIMATE TIME/TEMPERATURE RELATIONS HIPS IN SCALDS 120°F More than 5 ...

  • Bradford White EFTM - page 17

    Internet Version for Reference Only Figure 11. Typical Plumbing Sc hematic for Zoned He ating SECTION VI: VENTING WARNING The vent system must be properl y installed. Failure to properly inst all the vent sy stem could res ult in property damage, pe rso nal injury, or death. DO NOT install dam aged venting system compone nts. If dam age is evident ...

  • Bradford White EFTM - page 18

    Internet Version for Reference Only CAUTION Check to make sure flue gases do n ot recirculate into the air intake termina l when using direct venting. If the water heater is havi ng service iss ues, flue reci rculation m ay be a cont ributing fact or. Even wh en the mi nimum vent t erminal separation distances are followed, recirculation may still ...

  • Bradford White EFTM - page 19

    Internet Version for Reference Only Figure 12a. Vent Terminal Clearances (Other than Direct Vent or “Power Vented” Installati ons) Canadian Installations 1 US Installations 2 Canadian Installations 1 US Installations 2 A= Clearance above grade, veranda, porch, deck or balcony 12 inches (30 cm) 12 inches (30 cm) H= Clearance to each side of cent ...

  • Bradford White EFTM - page 20

    Internet Version for Reference Only Figure 12b. Direct Vent Terminal Clearances Canadian Installations 1 US Installations 2 Canadian Installations 1 US Installations 2 A= Clearance above grade, veranda, porch, deck or balcony 12 inches (30 cm) 12 inches (30 cm) H= Clearance to each side of center line extended above meter/regulator assembly 3 feet ...

  • Bradford White EFTM - page 21

    Internet Version for Reference Only The vent system m ust terminate so that proper clearances are mainta ined as cited in local codes or the latest edition of the National Fuel Gas Code , ANSI Z223. 1.73.4e and 7.8a, b as f ollows: 1. Do not terminate near soffit vent s or crawl space or other area where condensate or vapor could crea te a nuisance ...

  • Bradford White EFTM - page 22

    Internet Version for Reference Only 2. Use the prop er PVC cement to secure the 90° exhaust vent and air intake terminals provided with the water heater to the plastic pipes. T he distance between th e back edge of the 90° exhaust vent termi nal and the exterior wall (see Figure 13) m ust be 6 inches (12.7 cm) more fo r the exhaust vent terminal ...

  • Bradford White EFTM - page 23

    Internet Version for Reference Only Figure 14. Typical Vertical Di rect Vent System Installation Through The Wal l Venting Wit h Low Ground Cleara nce: When venting cannot ex it through the wall at a h eight greater than or equal to 12” (30.5 cm) (and above expected snow level) from the groun d, then the installation must be modified as show n be ...

  • Bradford White EFTM - page 24

    Internet Version for Reference Only Max imu m Ve nt Le ngt h: Direct Vent Maximum Vent Length (Combine d Maximum Length for Intake and Exhaust) Model Number Max Vent Le ngth (feet) 3" PVC, CPVC, or ABS Max Vent Le ngth (feet) 4" PVC, CPVC, or ABS EF60T125, EF 100T150 120 170 EF60T150, EF 100T199 100 150 EF60T199, EF 100T250 EF100T300 80 6 ...

  • Bradford White EFTM - page 25

    Internet Version for Reference Only NOTICE This unit ca n be vente d using onl y PVC (C lass 160, AS TM D-2241 Schedule 40, ASTM D-1 785; or Cellular Core Sch edule 40 DWV, ASTM F-891), Schedule 40 CPVC (ASTM F-411), or A BS (ASTM D-2661) pipe. The fittings, other than the TERMINATIONS should be equivale nt to PVC- DWV fittings meeting ASTM F-2665. ...

  • Bradford White EFTM - page 26

    Internet Version for Reference Only Figure 16. Typical Horizo ntal Power Vent System Vertical Installation: Vertical venting must be supported ever y 5 feet of vertical run and ever y 3 feet of horizontal run of ven t pipe length. Stress levels in the pipe and fittings can be significantly in creased by improper installation. If rigid pipe clamps a ...

  • Bradford White EFTM - page 27

    Internet Version for Reference Only Follow the following procedure to v ent through the roof: 1. Cut the necessary holes through the roof and ceiling 2. Install the exhaust vent and air i ntake plastic pipes as sh own in Figu re 17. Ma ke sure that t he installat ion meets the local codes and/or The National Fuel Gas Co de ANSI Z223.1 (Latest Editi ...

  • Bradford White EFTM - page 28

    Internet Version for Reference Only Figure 18. Vent Terminal (Low Gr ound Clearance) Maximum Vent Length Determination Power Vent Maximum Vent Length Model Number Max Vent Len gth (feet) 3" PVC, CPVC, or ABS Max Vent Le ngth (feet) 4" PVC, CPVC, or ABS EF60T125, EF 100T150 120 170 EF60T150, EF 100T199 100 150 EF60T199, EF 100T250 EF100T30 ...

  • Bradford White EFTM - page 29

    Internet Version for Reference Only MULTIPLE INTAKE/EXHAUST TERMINAL SEPARATION DISTANCES Note: When installing multiple in take/exhaust ter minals on the same wall of a building, the nearest intake terminal must be at le ast 5 feet from the nearest exhaust term inal. 29 ...

  • Bradford White EFTM - page 30

    Internet Version for Reference Only CONCENTRIC VENT TERMINAL IN STALLATION PROCEDURE WARNING Improper inst allati on, adjustment, servi ce, or ma intenance can cause pr operty dam age, personal i njury, or deat h. Consult a qualified i nstaller, service agency, or the gas supp lier for info rm ation or assistance. This kit must be used only for ter ...

  • Bradford White EFTM - page 31

    Internet Version for Reference Only Figure 21. Rain Cap to Small Vent Pipe Ass’y 5. In stall concentric Y fitting and pip e assembly through the structure’s ho le and field-supplied roof boot/flashing. Do not allow i nsulation or other m aterials to accumulate insi de pipe asse mbly whe n install ing through the hole. 6. Secure assembly to roof ...

  • Bradford White EFTM - page 32

    Internet Version for Reference Only NOTICE Position termination where v ent vapors will not damage plants/sh rubs or air conditioning equipment . Position termination where vent vapors will not be adversely affected by wind condition. Position termination where it will not be damaged or be subjected to foreign objects. Position termination where va ...

  • Bradford White EFTM - page 33

    Internet Version for Reference Only INITIAL PREPARATION 1. Make sure the solvent cem ent you are planni ng to use is designed for the specific a pplication you are attempting. 2. Know the physical and chemical characteristics and lim ita tions of the PVC, PVC cellular core, ABS or CPVC piping materials th at you are about to use. 3. Know the reputa ...

  • Bradford White EFTM - page 34

    Internet Version for Reference Only CAUTION The water heater and individ ual shutoff valve m ust be di sconnected from the gas supply piping system during any pressure testing of t he system at test press ures in excess of ½ psi (3.5 kPa). The wate r heater must be isolated from the gas supply piping system by closing its manual shut off valve dur ...

  • Bradford White EFTM - page 35

    Internet Version for Reference Only SECTION VIII: ELEC TRICAL CONNECTIONS WARNING Turn off or disconnect the electrical pow er supply to the water heater before se rvicing. Label all wires prior to disconnection when servicing co ntrols. Wiring errors can cause impro per and dange rous operation . Verify proper operation after servicing. All electr ...

  • Bradford White EFTM - page 36

    Internet Version for Reference Only SECTION IX: OPER ATING INSTRUCTIONS WARNING Water heaters are heat-producin g appliances. To avoid damage or injury ther e must be no materials stored again st the water heater or direct vent syst em, and prope r care must be taken to av oid unnecessary contact (especially by children) with the water heater and d ...

  • Bradford White EFTM - page 37

    Internet Version for Reference Only LIGHTING INSTRUCTIONS Figure 26. Lighting Instruction Label TEMPERATURE ADJUSTMENT The temperature selector knob of the therm o stat has been adjusted to 12 0°F when shipped from the factory. NOTICE The lower the temperature setting, the gr eater the energy efficiency, both to heat the water and to m aintain the ...

  • Bradford White EFTM - page 38

    Internet Version for Reference Only Condensation does not mean your tank is leaking. Most of reported tank leak s on installation are proven to be condensation. To avoi d unnecessary inconvenience an d expe nse, m ake sure the tank is leaking before calling an independent servicin g contractor or qualified service professional. DANGER Hotter water ...

  • Bradford White EFTM - page 39

    Internet Version for Reference Only SECTION X: MAINTENANCE DANGER DO NOT ATTEMPT TO REPAIR GAS VALVE. DO NOT ATTEM PT TO REPAIR IGNITION M ODULE. DO NOT ATTE MPT TO REPAIR VENTUR I. DO NOT ATTEMPT TO REPAIR THERMOSTAT BOARD. DO NOT ATTEMPT TO REPAIR TRANSFORMER. DO NOT ATTEM PT TO REPA IR PRESSURE SWITCH. GENERAL KEEP APPLIANCE AREA CLEAR AN D FREE ...

  • Bradford White EFTM - page 40

    Internet Version for Reference Only DRAINING WATER HEATER The water heater m ust be drained if it is to be shut down and expose d to freezing tem perat ures. Maintenance a nd service procedures may also re quire draining the water heate r. 1. Turn off the water heater electrical disconnect switch. 2. Connect a hose to the drain valve. 3. Locate hos ...

  • Bradford White EFTM - page 41

    Internet Version for Reference Only ANODE INSPECTION AND REPLACEMENT This water heater is equipped with multiple sacrificial anod es. Anodes protect the glass-line d tank from corrosi on by sacrificing themselves through electrolysis. When the anode material is co nsumed, there is no m o re protection and corrosion of the tank accelerat es. Inspect ...

  • Bradford White EFTM - page 42

    Internet Version for Reference Only Figure 28. Powered Anode locations DRAIN VALVE AN D TANK ACCESS PANEL The water heaters a re equipped with a ¾ inch drain valve. An access panel covers t he cleanout openi ng in th e tank, which is sealed by a gasket a nd cover. RELIE F VALVE At least twice a year, the temperat ure and pressure relief va lve s h ...

  • Bradford White EFTM - page 43

    Internet Version for Reference Only COMBUSTION SYSTEM INSPECTION Inspect the operation o f the com bustion system monthly. Us e the following procedure to in spect the combustion system . 1. Turn off the main power switch of the water heater. 2. Adjust the thermostat to the Min. setting. 3. Remove the top of the c ombustion s urround by unlatching ...

  • Bradford White EFTM - page 44

    Internet Version for Reference Only SECTION XII: PARTS LIST Customer must specify complete model number and serial number when ordering service parts. EF™ – Series Water Heater 1 Combustion Surround Ass'y 2 Burner Ass'y (Specify model) 3 2nd Pass Top Collector Cover 4 Screw 10-16 x 3/4 5 Vent Termination Elbow 6 Thermostat Sensor Prob ...

  • Bradford White EFTM - page 45

    Internet Version for Reference Only 1 Combustion Surround Ass'y AA Keeper Latch & Catch BB Screw 8-32 x 1/2 RHCR CC Ignition Control Ass'y DD Jacket Head 28 1/4" Grey EE Switch Main Po wer FF Potentiometer GG Combustion Surround JJ Surround Bas/Jacket Head Customer must specify complete model number and serial number wh en orderi ...

  • Bradford White EFTM - page 46

    Internet Version for Reference Only 2 Combustion Ass'y (pictured previous page) 1A Combustion Ass’y (Specify model) 15A Gasket Blower Transition (Specify model) 2A Blower/Gas Valve Ass’y (Specify model) 16A Screw 8 -32 x 1/4 RHCR 3A Burner Ass’y (Specify model) 17A Gasket Flame Sensor 4A Blower – EBM (Specify model) 18A Flame Sensor 5A ...

  • Bradford White EFTM - page 47

    Internet Version for Reference Only NOTES 47 ...

  • Bradford White EFTM - page 48

    Internet Version for Reference Only NOTES 48 ...

Produzent Bradford White Kategorie Water Heater

Dokumente, die wir vom Produzenten des Geräts Bradford White EFTM erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Bradford White
- Bedienungsanleitungen EFTM
- Produktkarten Bradford White
- Informationsbroschüren
- oder Energieetiketten Bradford White EFTM
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Bradford White EFTM.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Bradford White EFTM, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Bradford White EFTM. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Bradford White EFTM ansehen.

Die komplette Bedienungsanleitung des Geräts Bradford White EFTM, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Bradford White EFTM hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Bradford White EFTM verständlich ist.

Eine gänzliche Bedienungsanleitung von Bradford White sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Bradford White EFTM bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Bradford White EFTM befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Bradford White EFTM, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Bradford White EFTM - die uns die ersten Schritte während der Nutzung von Bradford White EFTM erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Bradford White EFTM hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Bradford White EFTM im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Bradford White EFTM?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Bradford White EFTM nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Bradford White EFTM hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)