Bedienungsanleitung Bradford-White Corp 07.05.228.00

28 Seiten 0.89 mb
Download

Zur Seite of 28

Summary
  • Bradford-White Corp 07.05.228.00 - page 1

    MAGNUM Series Commercial Electric Booster Inst allation and Operating Manual I&W #07.05.228.00 No opere este equipo al menos que haya leído y comprendido el contenido de este manual! Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede result ar en un serio lesión o muerte. Este manual con tie ne im port ante ...

  • Bradford-White Corp 07.05.228.00 - page 2

    i CONTENTS Form No. EBOOSTERBWM-1009 INTRODUCTION The Bradford White Magnum Series Commercial Electric Booster water heater is designed for use with commercial dishwashers to boost the temperature of the regularly available hot water , usually 1 10°–150°F (43°–66°C) up to 180°F (82°C). W ater at 180°F (82°C) can be used as sanitizing ri ...

  • Bradford-White Corp 07.05.228.00 - page 3

    IMPORT ANT SAFETY INFORMA TION Form No. EBOOSTERBWM-1009 1 ELECTRIC SHOCK HAZARD: • This unit must be inst alled by qualified, trained inst allers. Installation must conform to all local electrical and plumbing codes. Check with your local plumbing and electrical inspectors for proper procedures and codes. • T urn power OFF at disconnect switch ...

  • Bradford-White Corp 07.05.228.00 - page 4

    IMPORT ANT SAFETY INFORMA TION Form No. EBOOSTERBWM-1009 2 Unit s are equipped with a high temperature limit safety switch that will shut off power if the unit overheat s. Cont act an Authorized Service Agent if high temperature limit safety switch cannot be reset or continues to trip. Inst all booster water heater as close as possible to the comme ...

  • Bradford-White Corp 07.05.228.00 - page 5

    MODEL DESCRIPTION SPECIFICA TIONS Form No. EBOOSTERBWM-1009 3 M a g n u m S e r i e s C o m m e r ci a l E l e c t r i c B o o s te r The Magnum Series Commercial Electric Booster water heater includes a booster heater with low-water cut-off system, temperature/pr essure relief valv e, pressure reduci ng valve with buil t-i n hig h pre ssu re by pa ...

  • Bradford-White Corp 07.05.228.00 - page 6

    Model kW V olt s Phase Amp Draw Breaker or Copper Conduit L1 L2 L3 Fuse Size Wire Size Size LI663CFC 6 208 1 29 29 - 40 8 1/2" (13 mm) LI663CFD 6 208 3 14 25 14 40 8 1/2" (13 mm) LI663CFE 6 240 1 25 25 - 40 8 1/2" (13 mm) LI663CFF 6 240 3 13 22 13 30 10 1/2" (13 mm) LI663CFM 6 480 36 1 1 6 15 14 1/2" (13 mm) LI693CFC 9 208 ...

  • Bradford-White Corp 07.05.228.00 - page 7

    SPECIFICA TIONS Form No. EBOOSTERBWM-1009 5 Wire size is based on THHN wire for branch circuit protection at .91 derate factor . Circuit breakers and fused disconnects are to be mounted remote and wired by contractor . Sizes are based on the 2002 NEC table 310-16. Conduit size based on conductors plus ground wire sizing per T able C1 from Appendix ...

  • Bradford-White Corp 07.05.228.00 - page 8

    INST ALLA TION Form No. EBOOSTERBWM-1009 6 General For th e most e ff ecti ve ope rati on, in st all th e boos ter wa ter he ater as close as possible to the commercial dish machine. The location must have a solid foundation or strong table/counter construction along with being clean and dry . Adequate front clearance is required to allow for acces ...

  • Bradford-White Corp 07.05.228.00 - page 9

    INST ALLA TION Form No. EBOOSTERBWM-1009 7 Figure 4. Components Shipped with the Magnum Series Commercial Electric Booster Legs Mounting Bracket s with Hardware T emperature/Pressure Gauge T emperature/Pressure Relief V alve Plastic Leg S tainless S teel Leg A set of mounting brackets or a set of legs are supplied with each booster water heater . T ...

  • Bradford-White Corp 07.05.228.00 - page 10

    INST ALLA TION Form No. EBOOSTERBWM-1009 8 T emperature/Pressure Relief V alves For pr otec tion a gain st ex cess ive pr ess ures a nd tem pera tur es in the booster heater , install temperature/pressure protective equipment required by local codes. The temperature/pressure relief valve supplied with this booster water heater is constructe d with ...

  • Bradford-White Corp 07.05.228.00 - page 11

    INST ALLA TION Form No. EBOOSTERBWM-1009 9 Plumbing Connections Use the following procedures to connect the inlet and outlet water lines as well as inspect the system once the plumbing connections are complete. Do not connect an exp ansion t ank of any type to booster water heater lines. Use only plumbing material suit able for a minimum water temp ...

  • Bradford-White Corp 07.05.228.00 - page 12

    INST ALLA TION Form No. EBOOSTERBWM-1009 10 T emperature/Pressure Gauge T emperature/Pressure Relief V alve 150 psi (1034 kPa)/210°F (99°C) 3/4″ Union* Pressure Reducing V alve w/Bypass. Maximum 20 psi (138 kPa) flow pressure. T emperature/Pressure Gauge Outlet to dish machine Shock Absorber † Drain V alve* 3/4″ Union* Floor Drain Outlet In ...

  • Bradford-White Corp 07.05.228.00 - page 13

    INST ALLA TION Form No. EBOOSTERBWM-1009 11 DO NOT turn on power to the booster water heater until t ank has been filled with water and all air has been vented through dish machine rinse nozzle. The heating elements will burn out in seconds if operated when they are not immersed in water . Electrical — All Sizes and V olt ages General Bradfor d W ...

  • Bradford-White Corp 07.05.228.00 - page 14

    OPERA TION Form No. EBOOSTERBWM-1009 12 General Use the following procedures to operate the Magnum Series Commercial Electric Booster water heater . Read all safety messages in the Important Safety Information section before operating this equipment. DO NOT turn on power to the booster water heater until t ank has been filled with water and all air ...

  • Bradford-White Corp 07.05.228.00 - page 15

    MAINTENANCE Form No. EBOOSTERBWM-1009 13 General Bradford White Magnum Series Commercial Electric Booster water heaters are designed for maximum durability and performance, with minimum maintenance. ELECTRIC SHOCK HAZARD: • T u rn powe r OFF at di sconn ect sw itch/ circu it brea ker and allow unit to cool before performing any maintenance or cle ...

  • Bradford-White Corp 07.05.228.00 - page 16

    MAINTENANCE TROUBLESHOOTING GUIDE Form No. EBOOSTERBWM-1009 14 General ELECTRIC SHOCK HAZARD: • T urn power OFF at disconnect switch/circuit breaker and allow unit to cool before performing any maintenance or cleaning. • This unit must be serviced by qualified personnel only . Service by unqualified personnel may lead to electric shock or burn. ...

  • Bradford-White Corp 07.05.228.00 - page 17

    TROUBLESHOOTING GUIDE Form No. EBOOSTERBWM-1009 15 Symptom Probable Cause Corrective Action W ater reaches 180°F (82°C) but does not last through the entire dishwasher operation. Low incoming water temperature. Incoming water temperature must be adequate for booster size. Increase incoming water temperature. Incoming water temperature drops. Prim ...

  • Bradford-White Corp 07.05.228.00 - page 18

    TROUBLESHOOTING GUIDE Form No. EBOOSTERBWM-1009 16 Symptom Probable Cause Corrective Action W ater at dish machine is not at the proper temperature. Gauge(s) not working properly . Check temperature of water with a thermometer to be certain gauges are working correctly . If not, replace gauge(s). Thermostat set too low . Adjust or recalibrate. If t ...

  • Bradford-White Corp 07.05.228.00 - page 19

    ACCESSORIES Form No. EBOOSTERBWM-1009 17 St ainless Steel Adjust able Legs 1. Carefully place the unit on its side. Do not lay unit on the side with the control p anel. Damage to the unit could occur . 2. Thread the adjustable legs into the existing leg holes on the bottom of the unit. 3. Af ter all legs are secure, return the unit to the upright p ...

  • Bradford-White Corp 07.05.228.00 - page 20

    WIRING DIAGRAMS Form No. EBOOSTERBWM-1009 18 10-01-454 6 – 9 kW Wiring Diagram, All V oltages, Single- or Three-Phase 10-01-448 12 – 18 kW Wiring Diagram, All V oltages, Three-Phase ...

  • Bradford-White Corp 07.05.228.00 - page 21

    WIRING DIAGRAMS Form No. EBOOSTERBWM-1009 19 10-01-452 12 – 15 kW Wiring Diagram, 208 and 240 V , Single-Phase 10-01-447 18 kW Wiring Diagram, 208 and 240 V , Single-Phase ...

  • Bradford-White Corp 07.05.228.00 - page 22

    WIRING DIAGRAMS Form No. EBOOSTERBWM-1009 20 10-01-432 24 – 30 kW Wiring Diagram, 240 V , Single-Phase 10-01-433 24 – 36 kW Wiring Diagram, 208 and 240 V , Three-Phase ...

  • Bradford-White Corp 07.05.228.00 - page 23

    WIRING DIAGRAMS Form No. EBOOSTERBWM-1009 21 10-01-435 24 – 36 kW Wiring Diagram, 480 V , Three-Phase 10-01-436 36 kW Wiring Diagram, 240 V , Single-Phase ...

  • Bradford-White Corp 07.05.228.00 - page 24

    WIRING DIAGRAMS Form No. EBOOSTERBWM-1009 22 10-01-434 45 – 57 kW Wiring Diagram, 480 V , Three-Phase 10-01-437 36 – 57 kW Wiring Diagram, 208 and 240 V , Three-Phase ...

  • Bradford-White Corp 07.05.228.00 - page 25

    LIMITED COMMERCIAL W A TER HEA TER W ARRANTY Form No. EBOOSTERBWM-1009 23 WHA T DOES THIS LIMITED W ARRANTY COVER? This l imit ed war rant y cov ers bo th the t ank and comp onen t pa rt s for leakage or other m alfunction caused by d efects in ma terials and/or workmanship. It extends to the first buyer and to any subsequent owner(s) as long as th ...

  • Bradford-White Corp 07.05.228.00 - page 26

    LIMITED COMMERCIAL W A TER HEA TER W ARRANTY (CONTINUED) Form No. EBOOSTERBWM-1009 24 WHA T SHOULD YOU DO T O KEEP THE W ARRANTY IN EFFECT? T o facilitate warranty assist ance, you should: 1. Follow all instructions enclosed with the product. 2. Retain all bills of sale or receipts for proof of inst allation, etc. 3. Contact your installer , dealer ...

  • Bradford-White Corp 07.05.228.00 - page 27

    NOTES Form No. EBOOSTERBWM-1009 25 ...

  • Bradford-White Corp 07.05.228.00 - page 28

    Printed in U.S.A. October 2009 Part No. 07.04.474.00 Form No. EBOOSTERBWM-1009 Ambler , P A 19002 T echnical Service 800.334.3393 Service Parts 800.538.2020 W arranty Service 800.531.21 1 1 www .bradfordwhite.com ...

Produzent Bradford-White Corp Kategorie Water Heater

Dokumente, die wir vom Produzenten des Geräts Bradford-White Corp 07.05.228.00 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Bradford-White Corp
- Bedienungsanleitungen 07.05.228.00
- Produktkarten Bradford-White Corp
- Informationsbroschüren
- oder Energieetiketten Bradford-White Corp 07.05.228.00
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Bradford-White Corp 07.05.228.00.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Bradford-White Corp 07.05.228.00, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Bradford-White Corp 07.05.228.00. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Bradford-White Corp 07.05.228.00 ansehen.

Die komplette Bedienungsanleitung des Geräts Bradford-White Corp 07.05.228.00, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Bradford-White Corp 07.05.228.00 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Bradford-White Corp 07.05.228.00 verständlich ist.

Eine gänzliche Bedienungsanleitung von Bradford-White Corp sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Bradford-White Corp 07.05.228.00 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Bradford-White Corp 07.05.228.00 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Bradford-White Corp 07.05.228.00, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Bradford-White Corp 07.05.228.00 - die uns die ersten Schritte während der Nutzung von Bradford-White Corp 07.05.228.00 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Bradford-White Corp 07.05.228.00 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Bradford-White Corp 07.05.228.00 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Bradford-White Corp 07.05.228.00?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Bradford-White Corp 07.05.228.00 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Bradford-White Corp 07.05.228.00 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)