Bedienungsanleitung Vanguard Heating VSGF28NTC

32 Seiten 1.23 mb
Download

Zur Seite of 32

Summary
  • Vanguard Heating VSGF28NTC - page 1

    Shown with optional cabinet mantel, hearth base, and trim accessories. Save this manual for future reference. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vici ...

  • Vanguard Heating VSGF28NTC - page 2

    2 107157 UNVENTED NA TURAL GAS FIREPLACE ® For more information, visit www.desatech.com SAFETY INFORMA TION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the fireplace may not be working proper ...

  • Vanguard Heating VSGF28NTC - page 3

    3 107157 OWNER’S MANUAL For more information, visit www.desatech.com PRODUCT IDENTIFICA TION Figure 1 - Log Base Assembly, Split Oak Set Figure 2 - Fireplace Top Louver Assembly Fireplace Hood Bottom Louver Assembly Screen Assembly Top Outer Casing Firebox Support Optional Blower Assembly (Not Included) Rear Log Base Assembly Rear Burner Crossove ...

  • Vanguard Heating VSGF28NTC - page 4

    4 107157 UNVENTED NA TURAL GAS FIREPLACE ® For more information, visit www.desatech.com AIR FOR COMBUSTION AND VENTILA TION Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to ke ...

  • Vanguard Heating VSGF28NTC - page 5

    5 107157 OWNER’S MANUAL For more information, visit www.desatech.com AIR FOR COMBUSTION AND VENTILA TION Continued DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install ...

  • Vanguard Heating VSGF28NTC - page 6

    6 107157 UNVENTED NA TURAL GAS FIREPLACE ® For more information, visit www.desatech.com AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one wi ...

  • Vanguard Heating VSGF28NTC - page 7

    7 107157 OWNER’S MANUAL For more information, visit www.desatech.com INST ALLA TION Continued CAUTION: This fireplace cre- ates warm air currents. These cur- rents move heat to wall surfaces next to fireplace. Installing fire- place next to vinyl or cloth wall coverings or operating fireplace where impurities (such as to- bacco smoke, aromatic ca ...

  • Vanguard Heating VSGF28NTC - page 8

    8 107157 UNVENTED NA TURAL GAS FIREPLACE ® For more information, visit www.desatech.com INSTALLATION CLEARANCES .5 2 7/16 7/8 1 3 / 4 3 1 / 2 5 1 / 4 7 8 3 / 4 10 1 / 2 12 1 / 4 1 4 6 8 10 12 14 16 FIREBO X INCHES INCHES INST ALLA TION Continued ASSEMBLING AND ATTACHING OPTIONAL BRASS TRIM (Included with Mantel Accessory) IMPORTANT: If you are rec ...

  • Vanguard Heating VSGF28NTC - page 9

    9 107157 OWNER’S MANUAL For more information, visit www.desatech.com Figure 10 - Installing Cabinet Mantel Cabinet Mantel INST ALLA TION Continued 4. Place hearth base accessory against wall at installation location. Cut an ac- cess hole in hearth top to run gas line to fireplace (see Figure 9, page 8). Make sure to locate access hole so cabi- ne ...

  • Vanguard Heating VSGF28NTC - page 10

    10 107157 UNVENTED NA TURAL GAS FIREPLACE ® For more information, visit www.desatech.com INSTALLING GAS PIPING TO FIREPLACE LOCATION Installation Items Needed Before installing fireplace, make sure you have the items listed below. • piping (check local codes) • sealant (resistant to propane/LP gas) • equipment shutoff valve * • test gauge ...

  • Vanguard Heating VSGF28NTC - page 11

    11 107157 OWNER’S MANUAL For more information, visit www.desatech.com CSA/AGA Design- Certified Equipment Shutoff Valve With 1/8" NPT Tap* 3" Minimum From Gas Meter (5" W.C. to 10.5" W.C. Pressure) Approved Flexible Gas Line Pipe Nipple Cap Tee Joint Sediment Trap Figure 17 - Gas Connection * Purchase the optional CSA/AGA desi ...

  • Vanguard Heating VSGF28NTC - page 12

    12 107157 UNVENTED NA TURAL GAS FIREPLACE ® For more information, visit www.desatech.com Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Fig- ure 20). 2. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter . 3. Check all joints from gas ...

  • Vanguard Heating VSGF28NTC - page 13

    13 107157 OWNER’S MANUAL For more information, visit www.desatech.com WARNING: You must operate this fireplace with the fireplace screen in place. Make sure fire- place screen is in place before running fireplace. Figure 26 - Installing Fireplace Screen Notches Screws for Mounting Screen WARNING: Failure to position the parts in accordance with t ...

  • Vanguard Heating VSGF28NTC - page 14

    14 107157 UNVENTED NA TURAL GAS FIREPLACE ® For more information, visit www.desatech.com LIGHTING INSTRUCTIONS WARNING: You must operate this fireplace with the fireplace screen in place. Make sure fire- place screen is installed before running fireplace. NOTICE: During initial operation of new fireplace, burning logs will give off a paper-burning ...

  • Vanguard Heating VSGF28NTC - page 15

    15 107157 OWNER’S MANUAL For more information, visit www.desatech.com LIGHTING INSTRUCTIONS WARNING: You must operate this fireplace with the fireplace screen in place. Make sure fire- place screen is installed before running fireplace. NOTICE: During initial operation of new fireplace, burning logs will give off a paper-burning smell. Orange fla ...

  • Vanguard Heating VSGF28NTC - page 16

    16 107157 UNVENTED NA TURAL GAS FIREPLACE ® For more information, visit www.desatech.com Figure 30 - Pilot WARNING: Do not operate heater between locked positions. CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve. VARIABLE CONTROL OPERATION The variable control valve can be set to any heat setting and flame heigh ...

  • Vanguard Heating VSGF28NTC - page 17

    17 107157 OWNER’S MANUAL For more information, visit www.desatech.com OPERA TING FIREPLACE Continued INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT FLAME PATTERN Figure 31 shows a correct pilot flame pat- tern. Figure 32 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the ther ...

  • Vanguard Heating VSGF28NTC - page 18

    18 107157 UNVENTED NA TURAL GAS FIREPLACE ® For more information, visit www.desatech.com FRONT BURNER FLAME PATTERN Figure 33 shows correct front burner flame pattern. Figure 34 shows incorrect front burner flame pattern. The incorrect burner flame pattern shows yellow tipping at top of blue flame. WARNING: If front burner flame pattern shows yell ...

  • Vanguard Heating VSGF28NTC - page 19

    19 107157 OWNER’S MANUAL For more information, visit www.desatech.com POSSIBLE CAUSE 1. Ignitor electrode not connected to igni- tor cable 2. Piezo ignitor nut is loose 3. Ignitor cable pinched or wet 4. Broken ignitor cable 5. Bad piezo ignitor 6. Ignitor electrode broken 7. Ignitor electrode positioned wrong 1 . Gas supply turned off or equipme ...

  • Vanguard Heating VSGF28NTC - page 20

    20 107157 UNVENTED NA TURAL GAS FIREPLACE ® For more information, visit www.desatech.com TROUBLESHOOTING Continued OBSERVED PROBLEM One or both burners do not light after ODS/ pilot is lit Delayed ignition of one or both burners Burner backfiring during combustion Yellow flame in front burner during burner combustion Slight smoke or odor during in ...

  • Vanguard Heating VSGF28NTC - page 21

    21 107157 OWNER’S MANUAL For more information, visit www.desatech.com TROUBLESHOOTING Continued POSSIBLE CAUSE 1. Metal expanding while heating or con- tracting while cooling 1. Fireplace burning vapors from paint, hair spray , glues, cleaners, chemicals, new carpet, etc. (See IMPORT ANT state- ment above) 2. Gas leak. See W arning statement abov ...

  • Vanguard Heating VSGF28NTC - page 22

    22 107157 UNVENTED NA TURAL GAS FIREPLACE ® For more information, visit www.desatech.com ACCESSORIES Purchase these fireplace accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800-432-2382 for information. You can also write to the ad- dress listed on the back page of th ...

  • Vanguard Heating VSGF28NTC - page 23

    23 107157 OWNER’S MANUAL For more information, visit www.desatech.com EQUIPMENT SHUTOFF VALVE - GA5010 For all models. Equipment shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe. SLIM HEARTH BASE (Not Shown) G3005J Series - Jade Marble Laminate G3005S Series - Sandstone Marble Laminate G3005B Series - Black Onyx Marble Laminate The s ...

  • Vanguard Heating VSGF28NTC - page 24

    24 107157 UNVENTED NA TURAL GAS FIREPLACE ® For more information, visit www.desatech.com 26 7 8 7 7 18 6 12 11 7 5 9 17 22 15 10 25 13 5 5 5 5 20 14 18 31 28 23 29 19 27 30 24 16 21 32 1 2 3 4 ILLUSTRA TED PA R T S BREAKDOWN LOG BASE ASSEMBLY VARIABLE MANUALLY- CONTROLLED MODEL VSGF28NVA ...

  • Vanguard Heating VSGF28NTC - page 25

    25 107157 OWNER’S MANUAL For more information, visit www.desatech.com P ARTS LIST LOG BASE ASSEMBLY VARIABLE MANUALLY- CONTROLLED MODEL VSGF28NVA This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 22 of this manual. KEY NO. PART NUMBER DESCRIPTION QTY. 1 ...

  • Vanguard Heating VSGF28NTC - page 26

    26 107157 UNVENTED NA TURAL GAS FIREPLACE ® For more information, visit www.desatech.com ILLUSTRA TED PA R T S BREAKDOWN FIREPLACE VSGF28NVA 1 2 3 16 4 6 12 18 10 10 7 13 16 16 16 7 17 14 5 16 16 15 8 9 16 11 11 11 ...

  • Vanguard Heating VSGF28NTC - page 27

    27 107157 OWNER’S MANUAL For more information, visit www.desatech.com P ARTS LIST FIREPLACE VSGF28NVA This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 22 of this manual. KEY NO. PART NUMBER DESCRIPTION QTY. 1 101357-01 Top Outer Casing 1 2 103207-01 Ou ...

  • Vanguard Heating VSGF28NTC - page 28

    28 107157 UNVENTED NA TURAL GAS FIREPLACE ® For more information, visit www.desatech.com ILLUSTRA TED PA R T S BREAKDOWN LOG BASE ASSEMBLY THERMOSTAT- CONTROLLED MODEL VSGF28NTC 17 5 26 7 8 7 7 18 6 12 11 1 2 4 3 6 9 15 10 25 13 28 5 5 5 5 21 24 22 18 23 12 6-2 19 14 27 29 20 16 ...

  • Vanguard Heating VSGF28NTC - page 29

    29 107157 OWNER’S MANUAL For more information, visit www.desatech.com P ARTS LIST LOG BASE ASSEMBLY THERMOSTAT- CONTROLLED MODEL VSGF28NTC This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 22 of this manual. KEY NO. PART NUMBER DESCRIPTION QTY. 1 104388 ...

  • Vanguard Heating VSGF28NTC - page 30

    30 107157 UNVENTED NA TURAL GAS FIREPLACE ® For more information, visit www.desatech.com ILLUSTRA TED PA R T S BREAKDOWN FIREPLACE VSGF28NTC 1 2 3 4 16 16 6 12 18 10 10 7 13 16 26 24 16 23 25 20 24 24 21 16 16 7 17 14 5 16 16 15 8 9 19 22 11 11 11 ...

  • Vanguard Heating VSGF28NTC - page 31

    31 107157 OWNER’S MANUAL For more information, visit www.desatech.com P ARTS LIST FIREPLACE VSGF28NTC This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 22 of this manual. KEY NO. PART NUMBER DESCRIPTION QTY. 1 101357-01 Top Outer Casing 1 2 103207-01 Ou ...

  • Vanguard Heating VSGF28NTC - page 32

    LIMITED WARRANTY VENT-FREE NATURAL GAS FIREPLACE DESA International warrants this product to be free from defects in materials and components for four ( 4) years and five (5) years on stainless steel burners from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applica ...

Produzent Vanguard Heating Kategorie Indoor Fireplace

Dokumente, die wir vom Produzenten des Geräts Vanguard Heating VSGF28NTC erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Vanguard Heating
- Bedienungsanleitungen VSGF28NTC
- Produktkarten Vanguard Heating
- Informationsbroschüren
- oder Energieetiketten Vanguard Heating VSGF28NTC
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Vanguard Heating VSGF28NTC.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Vanguard Heating VSGF28NTC, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Vanguard Heating VSGF28NTC. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Vanguard Heating VSGF28NTC ansehen.

Die komplette Bedienungsanleitung des Geräts Vanguard Heating VSGF28NTC, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Vanguard Heating VSGF28NTC hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Vanguard Heating VSGF28NTC verständlich ist.

Eine gänzliche Bedienungsanleitung von Vanguard Heating sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Vanguard Heating VSGF28NTC bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Vanguard Heating VSGF28NTC befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Vanguard Heating VSGF28NTC, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Vanguard Heating VSGF28NTC - die uns die ersten Schritte während der Nutzung von Vanguard Heating VSGF28NTC erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Vanguard Heating VSGF28NTC hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Vanguard Heating VSGF28NTC im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Vanguard Heating VSGF28NTC?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Vanguard Heating VSGF28NTC nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Vanguard Heating VSGF28NTC hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)