  • Lennox International Inc. 15CHAX Series - page 1

    01/08 *2P0108* Page 1 505,201M *P505201M* RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE  2006 Lennox Industries Inc. Dallas, Texas, USA Table of Contents Shipping & Packing List 1 . . . . . . . . . . . . . . . . . . . . . . . . . Unit Dimensions 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Parts Arrangement 3 . . . . . . ...

  • Lennox International Inc. 15CHAX Series - page 2

    HORIZONTAL SUPPLY AIR OPENING BACK VIEW END VIEW TOP VIEW A B FRONT VIEW HORIZONTAL RETURN AIR OPENINGS (2) C L FG H J K D E E D DOWN−FLOW SUPPLY AIR OPENING DOWNFLOW RETURN AIR OPENING E D E D END VIEW CONDENSATE DRAIN ELECTRICAL INLET 2−1/2 (64) 2−1/2 (64) 2−3/4 (70) 2−3/4 (70) 2−3/4 (70) 2−1/2 (64) AA CC DD FF BB EE E D 2 (51) Page ...

  • Lennox International Inc. 15CHAX Series - page 3

    Page 3 Parts Arrangement General These installation instructions are intended as a general guide only, for use by an experienced, licensed contractor (or equivalent). The 15CHAX units are single−package electric units designed for outdoor installation o n a rooftop or a slab. The units are equipped with a transformer and blower control for applic ...

  • Lennox International Inc. 15CHAX Series - page 4

    Page 4  For installation on combustible material. WARNING Product contains fiberglass wool. Disturbing the insulation in this product during installation, maintenance, or repair will expose you to fiberglass wool dust. Breathing this may cause lung cancer. (Fiberglass wool is known to the State of California to cause cancer.) Fiberglass wool may ...

  • Lennox International Inc. 15CHAX Series - page 5

    Page 5 Existing Common Vent Systems The 15CHAX packaged cooling units with auxiliary electric heat may replace an existing furnace which is being re- moved from a venting system commonly run with separate gas appliances. In this case, the existing vent system is likely to be too large to properly vent the remaining at- tached appliances. Conduct th ...

  • Lennox International Inc. 15CHAX Series - page 6

    Page 6 Filters Filters are not factory−supplied with the unit; however, optional internally installed filter kits are available. Filter kit 92 M 5 4 is used with 2, 2−1/2 and 3−ton units. Filter kit 92M55 is used with 3−1/2, 4 and 5−ton units. The filter kits accommodate the use of 1", 2" or 4" filters. If the optional filt ...

  • Lennox International Inc. 15CHAX Series - page 7

    Page 7 Unit must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electric Code, ANSI/NFPA No. 70 (latest edition) or CSA C22.2 Part 1 (latest edition). Power supply to the unit must comply with all applicable codes and NEC or CEC. A fused disconnect switch should be field provided for the u ...

  • Lennox International Inc. 15CHAX Series - page 8

    Page 8 Figure 7 15CHAX Series Packaged Electric Units Typical Wiring Diagram ...

  • Lennox International Inc. 15CHAX Series - page 9

    Page 9 Blower Control Board (A54) Electric shock hazard. Can cause injury or death. Before attempting to perform any service or m aintenance, turn the electrical power to unit OFF at disconnect switch(es). Unit may have multiple power supplies. WARNING ! 15CHAX units are equipped with a variable speed motor that is capable of maintaining a specifie ...

  • Lennox International Inc. 15CHAX Series - page 10

    Page 10 COOL The COOL jumper is used to determine the CFM during cooling operation. This jumper selection is activated for cooling when Y1 is energized. Th e blower motor runs at 80 percent of the selected air flow fo r the first 7−1/2 minutes of each cooling demand. This fea- ture allows for greater humidity removal and saves energy. In the cool ...

  • Lennox International Inc. 15CHAX Series - page 11

    Page 11 System Operation Monitor (LSOM) The system operation monitor (A132) detects the most common fault conditions in the air conditioning system. Whe n an abnormal condition is detected, the module com- municates the specific condition through its ALERT and TRIP lights. The module is capable of detecting both me- chanical and electrical system p ...

  • Lennox International Inc. 15CHAX Series - page 12

    Page 12 Table 5 System Operation Monitor LED Troubleshooting Codes Status LED Condition Status LED Description Status LED Troubleshooting Information Green Power" LED ON Module has power 24VAC control power is present at the module terminal. Green Power" LED OFF Module not powering up Determine/verify that both R and C module termin ...

  • Lennox International Inc. 15CHAX Series - page 13

    Page 13 Unit Start−Up and Operation Each 15CHAX packaged cooling unit is factory−charged with R−410A refrigerant. The compressor is hermetically sealed, internally sprung and base−mounted with rubber−insulated hold−down bolts. Pre−Start Check List: 1 − M a ke sure refrigerant lines do not rub against the cabi- net or each other. 2 ? ...

  • Lennox International Inc. 15CHAX Series - page 14

    Page 14 Condenser Fan Clearances The top of the condenser fan should be 1−1/2 inches from the bottom of the top grille. This dimension should be checked and the fan should be adjusted accordingly any time servicing of the outdoor fan system is required. Maintenance At the start of each cooling season, this equipment should be serviced by a licens ...

Produzent Lennox International Inc. Kategorie Air Conditioner

Dokumente, die wir vom Produzenten des Geräts Lennox International Inc. 15CHAX Series erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Lennox International Inc.
- Bedienungsanleitungen 15CHAX Series
- Produktkarten Lennox International Inc.
- Informationsbroschüren
- oder Energieetiketten Lennox International Inc. 15CHAX Series
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Lennox International Inc. 15CHAX Series.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Lennox International Inc. 15CHAX Series, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Lennox International Inc. 15CHAX Series. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Lennox International Inc. 15CHAX Series ansehen.

Die komplette Bedienungsanleitung des Geräts Lennox International Inc. 15CHAX Series, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Lennox International Inc. 15CHAX Series hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Lennox International Inc. 15CHAX Series verständlich ist.

Eine gänzliche Bedienungsanleitung von Lennox International Inc. sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Lennox International Inc. 15CHAX Series bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Lennox International Inc. 15CHAX Series befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Lennox International Inc. 15CHAX Series, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Lennox International Inc. 15CHAX Series - die uns die ersten Schritte während der Nutzung von Lennox International Inc. 15CHAX Series erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Lennox International Inc. 15CHAX Series hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Lennox International Inc. 15CHAX Series im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Lennox International Inc. 15CHAX Series?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Lennox International Inc. 15CHAX Series nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Lennox International Inc. 15CHAX Series hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)