Admiral ADM8IA - 10080010 - page 1
Read these instructions before operating the machine Lire ce manuel avant d’utiliser la machine Bitte lesen Sie diese Anleitungen, bevor Sie die Maschine in Gebrauch nehmen MOD EL: COUNTRY ADM8IA - 10080010 AUSTRALIA ADM8IB - 100800 20 BRITIAN ADM8IE - 10080030 EUROPE ADM8IS - 10080040 SWITZERLAND Operating Instructions (GB/USA) Manuel d’utilis ...
-
Admiral ADM8IA - 10080010 - page 2
TABLE OF CONTENTS ADMIRAL 86038270 05/22/07 1 Data Log/Table of Contents .............. 1 Safety Instructions ............................ 2 Controls ............................................ 3-5 Operations ........................................ 6-11 Troubleshooting ................................ 12 Blank Page ............................... ...
-
Admiral ADM8IA - 10080010 - page 3
SAFETY INSTRUCTIONS ADMIRAL 86038270 05/22/07 2 IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use. To reduce the risk of fire, electric shock, or injury: Connect to a properly grounde ...
-
Admiral ADM8IA - 10080010 - page 4
CONTROLS/COMPONENT LOCATIONS ADMIRAL 86038270 05/22/07 3 1. Main Handle. Used to pull and maneuver machine. 2. Handle Adjustment. Used to adjust height of handle. 3. Electrical Cord. 4. Solution Switch. Turns on pump. Continuous position (bottom) activates electro-valve to dispense solution to floor through jets. Intermittent position (up) requires ...
-
Admiral ADM8IA - 10080010 - page 5
CONTROLS/COMPONENT LOCATIONS ADMIRAL 86038270 05/22/07 4 1. Solution Accessory Tool Hookup. Used for various auxiliary cleaning tools. 2. Vacuum Hose Door. Used to connect various auxiliary 1 ½ inch cleaning tool vacuum hoses. 3. Brush Height Adjustment. Used to regulate brush height from storage position to various carpet heights. 4. Recovery Tan ...
-
Admiral ADM8IA - 10080010 - page 6
CONTROLS/COMPONENT LOCATIONS ADMIRAL 86038270 05/22/07 5 1. Solution Intake Cover. 2. Vacuum Intake Cover. 3. Float Shut-Off. 4. Clean-Out Opening. 5. Pour Spout. 6. Lift Handle. 2 1 3 4 5 6 6 ...
-
Admiral ADM8IA - 10080010 - page 7
FILLING OPERATIONS ADMIRAL 86038270 05/22/07 6 FILLING THE ADMIRAL NOTE: Use clean bucket of water to fill solution tank Do not put defoamer, solv ents, spotter or prespray chemicals in the solution tank . Do not allow water to spill into vacuum motor inlet. Dry spillage from top of solution tank before replacing recovery tank . CHEMICALS Suitable ...
-
Admiral ADM8IA - 10080010 - page 8
OPERATIONS ADMIRAL 86038270 05/22/07 7 Remove electrical cord and literature from recovery tank. Fill solution tank (see filling instructions page 6). Adjust brush to proper setting. Note: For good operation the brush must skim the carpet. If circuit breaker trips raise brush to prevent damage to motor or carpet. Plug cord into grounded outlet. Not ...
-
Admiral ADM8IA - 10080010 - page 9
OPERATIONS ADMIRAL 86038270 05/22/07 8 Select continuous setting to start solution spray or select intermittent setting to enable use of trigger switches to start solution spray. The intermittent setting requires the operator to hold any one of the three trigger switches in the “on” position with the fingers, and is typically used in small area ...
-
Admiral ADM8IA - 10080010 - page 10
CLEANING PROCEDURE ADMIRAL 86038270 05/22/07 9 Release intermittent trigger switches or turn off continuous setting on solution switch approximately 1 foot before ending cleaning pass. Push down on handle to raise vacuum shoe and brush before moving to the next cleaning pass. Overlap brush contact area a minimum of 1inch on the right (close cleanin ...
-
Admiral ADM8IA - 10080010 - page 11
CLEANING PROCEDURE ADMIRAL 86038270 05/22/07 1 0 To speed drying, use a Windblower ™ fan. Empty recovery tank by releasing dump hose. Use a hose with cold water to clean out the recovery tank. Also drain solution tank after each use. STEP 7 STEP 8 After cleaning, turn off all controls, return brush to storage position and carefully unplug machine ...
-
Admiral ADM8IA - 10080010 - page 12
ACCESSORY TOOL USAGE ADMIRAL 86038270 05/22/07 11 Turn on vacuum motor switch and set solution switch to intermittent position. Note: Be sure brush switch is in off p osition and brush is in storage position. Squeeze handle on accessory tool to begin cleaning. STEP 3 STEP 4 STEP 1 STEP 2 Use only one of the following acceptable accessory tools. 860 ...
-
Admiral ADM8IA - 10080010 - page 13
TROUBLESHOOTING CHART ADMIRAL 86038270 05/22/07 1 2 PROBLEM CAUSE SOLUTION No Power, Nothing Runs 1. Is the cord plugged in. 2. Circuit breaker tripped in building. 3. Faulty switch. 4. Faulty power cord or pigtail. 1. Plug in cord. 2. Reset breaker 3. Call for service. 4. Call for service. Vacuum Motor Will Not Run 1.Vacuum circuit breaker tripped ...
-
Admiral ADM8IA - 10080010 - page 14
ADMIRAL 86038270 05/22/07 1 3 THIS PAGE LEFT INTENTIONALLY BLANK ...
-
Admiral ADM8IA - 10080010 - page 15
WIRING DIAGRAM ADMIRAL 86038270 05/22/07 1 4 86268290 PRV NO. 88229 86268460 PRV NO. 88333 86268430 PRV NO. 88323 86268370 PRV NO. 88276 FILTER 86003650 PRV NO. 34362 86268430 PRV NO. 88323 86268430 - PRV NO. 88323 86238840 PRV NO. 41356 86238830 PRV NO. 41355 86268900 PRV NO. 88655 86266720 PRV NO. 880043 86268420 PRV NO. 88317 86001240 PRV NO. 14 ...
-
Admiral ADM8IA - 10080010 - page 16
MAINTENANCE ADMIRAL 86038270 05/22/07 15 PERIODIC MAINTENANCE Twice a month, flush a white vinegar solution (One quart vinegar to two gallons of water) or anti-browning solution (mixed as directed) through the extractor. This will prevent build-up of alkaline residue in the system. If spray jets become clogged, remove the spray tips, wash them thor ...
-
Admiral ADM8IA - 10080010 - page 17
MAINTENANCE ADMIRAL 86038270 05/22/07 16 ! WARNING: ONLY QUALIFIED MAI NTENA NCE PERSONNEL ARE T O PERFORM THE FOLLOWING REPAIRS. VACUUM MOTOR REPLACEMENT 1. Turn off all switches and unplug machine. 2. Remove recovery tank. 3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame. 4. ...
-
Admiral ADM8IA - 10080010 - page 18
MAINTENANCE ADMIRAL 86038270 05/22/07 17 ! WARNING: SOLUTION PUMP REPLACEMENT 1. Turn off all switches and unplug the ma chine. 2. Remove recovery tank. 3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame. 4. Remove solution hoses fro m fittings in pump. 5. Remove the (2) screws ...
-
Admiral ADM8IA - 10080010 - page 19
TECHNICAL SPECIFICATIONS ADMIRAL 86038270 05/22/07 18 POWER TYPE ELECTRICAL: 230-240 V, 7 A, 50 HZ ELECTRIC VACUUM MOTOR: (1) –3 stage, 1 hp, 99 cfm (2.80 cubic meters/min.) Waterlift – 117” (297cm) BRUSH: (1) 15” (38.1 cm.) SOLUTION PUMP: 100 PSI, diaphragm style, internal bypass SOLUTION CAPACITY: 8 gallons (30.3 ltr) RECOVERY CAPACIT Y: ...
Haben Sie eine Frage bezüglich Admiral ADM8IA - 10080010?
Nutzen Sie das untere Formular
Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Admiral ADM8IA - 10080010 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Admiral ADM8IA - 10080010 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.