    PCI-DAS1002 Multifunction Analog & Digit al I/O User's Guide Document Revision 4, July, 2007 © Copyright 2007 , Measurement Computing Co rporation ...

  • Measurement Specialties PCI-DAS1002 - page 3

    Your new Measurement Computing produc t comes with a fantastic extra — Management committed to your satisfaction! Refer to www.mccdaq.com/execteam.html for the names, titles, an d contact inform ation of each ke y executive at Measurement Computing. Thank you for choosing a Measurement Co mputing product— and congratulations! You own the f ines ...

  • Measurement Specialties PCI-DAS1002 - page 4

    Trademark and Copyright Information TracerDAQ, Universal Library, Harsh E nvironment Warranty , Measurement Compu ting Corporation, an d the Measurement Computing logo are either trademarks or registered trademarks of M easurement C omputing Corporation. Windows, Microsoft, and Visual Studio ar e either trad emar ks or registered trademarks of Micr ...

  • Measurement Specialties PCI-DAS1002 - page 5

    Table of Contents Preface About this U ser's Gu ide .......................................................................................................................7 What you will learn from this user's guide ..................................................................................... .................... 7 Conventions in ...

  • Measurement Specialties PCI-DAS1002 - page 6

    PCI-DAS1002 User's Manual Miscella neous ................................................................................................................................................... 22 Power consumption .............................................................................................................. ........................ ...

  • Measurement Specialties PCI-DAS1002 - page 7

    Preface About this User's Guide What you will learn from this user's guide This user's guide explain s how to inst all, confi gure, and us e the PCI-DAS 1002 so that y ou get the most out of its analog, digital, and timing I/O features. This user's guide also re fers you to related docum ents availa ble on our we b site, and t o ...

  • Measurement Specialties PCI-DAS1002 - page 8

    Chapter 1 Introducing the PCI-DAS1002 Overview: PCI-DAS1002 features This manual explains how to install and u se the PCI-DAS1002. This board is a multifunctio n analog and digital I/O board desi gned f or the PCI bus. The PCI-DAS1002 p rovides either 16 single-ended or eight differential analog inputs. Input ranges are software-selectable as eith ...

  • Measurement Specialties PCI-DAS1002 - page 9

    PCI-DAS1002 User's Manual Introducing the PCI-DAS1002 PCI-DAS1002 block diagram PCI-DAS1002 functions are illustrated in the block diagram shown here. Figure 1. PCI-DAS1002 function al block diagram 9 ...

  • Measurement Specialties PCI-DAS1002 - page 10

    Chapter 2 Installing the PCI-DAS1002 What is included with your PCI-DAS1002 As you unpack your board, make s ure each of the items shown bel ow is included: Hardware  PCI-DAS1002 Additional documentation In addition to this hard ware user's guide, you shoul d also receive the Quick Start Guide (available in PDF at www.mccdaq.c om/PDFma nual ...

  • Measurement Specialties PCI-DAS1002 - page 11

    PCI-DAS1002 User's Manual Installing the PCI-DAS1002  Signal termination a nd conditioning accessories MCC provides signal terminatio n and conditioning products for use with the PCI-D AS1002. Refer to the " Field wiring and signal ter mination " section for a complete list of com patible accessory products. Unpacking the PCI-DAS1 ...

  • Measurement Specialties PCI-DAS1002 - page 12

    PCI-DAS1002 User's Manual Installing the PCI-DAS1002 Configuring the hardware All hardware configuration options on the PCI-DAS1002 are software c ontrolled. You can select s ome of the configuration op tions using Insta Cal, such as the analog input conf igurat ion (16 si ngle-ended o r eight different ial channels ), and the source for t he ...

  • Measurement Specialties PCI-DAS1002 - page 13

    PCI-DAS1002 User's Manual Installing the PCI-DAS1002 Pinout – main I/O connector 8-channel differential mode Signal Name Pin Pin Signal Name GND 100 • • 50 GND N/C 99 • • 49 N/C N/C 98 • • 48 PC +5V N/C 97 • • 47 N/C N/C 96 • • 46 N/C A/D Int. Pacer Output 95 • • 45 A/D External Trigger N/C 94 • • 44 N/C N/C 93 ? ...

  • Measurement Specialties PCI-DAS1002 - page 14

    PCI-DAS1002 User's Manual Installing the PCI-DAS1002 16-channel single- ended mode Signal Name Pin Pin Signal Name GND 100 • • 50 GND N/C 99 • • 49 N/C N/C 98 • • 48 PC +5V N/C 97 • • 47 N/C N/C 96 • • 46 N/C A/D Int. Pacer Output 95 • • 45 A/D External Trigger In N/C 94 • • 44 N/C N/C 93 • • 43 N/C PC -12V 92 ? ...

  • Measurement Specialties PCI-DAS1002 - page 15

    PCI-DAS1002 User's Manual Installing the PCI-DAS1002 Cables 1 50 2 49 51 100 52 99 100 50 51 1 Key Key The re d stri pe ide nt i fi es pi n # 1 The r ed stripe iden ti fies pi n # 51 Ca ble is la be led “Pins 5 1-100 ”. Cable i s lab eled “Pins 1- 50”. Figure 2. C100FF- x cable Field wiring and signal termination The following MCC scre ...

  • Measurement Specialties PCI-DAS1002 - page 16

    Chapter 3 Programming and Developing Applications After following the installatio n instructions in Ch apter 2 , your board should now be inst alled and ready for use. Although the b oard is part of the larger D AS family , in general there may be no c orrespondence among registers for different boards. Software written at the reg ister level for o ...

  • Measurement Specialties PCI-DAS1002 - page 17

    Chapter 4 Calibrating the Board Introduction Calibrate the board u sing the Insta Cal utility after the board has fully warmed up. The reco mmended warm-up time is 15 m inutes. For best results, cal ibrate the boa rd immedi ately before m aking critical measurements. T he high resolution analog componen ts on the board are sensitive to temperature. ...

  • Measurement Specialties PCI-DAS1002 - page 18

    Chapter 5 Specifications Typical for 25 °C unless other wise specified. Specifications in italic text are guarantee d by design. Analog input Table 1. Analog input specifications Parameter Specification A/D converter type ADS7800 or equivalent Resolution 12 bits Number of channels 16 single-ended / 8 differential, software s electable Input ranges ...

  • Measurement Specialties PCI-DAS1002 - page 19

    PCI-DAS1002 User's Manual Specifications Accuracy Accuracies are l isted for a 20 0 kHz sam pling rate, 10 0 sample avera ge, single cha nnel operation, a 15 mi nute warm-up, and operational temperatures with in ±2 ° C of internal calibration temperature. Th e calibrator test source high side is tied to Channel 0 In and the low side is tied ...

  • Measurement Specialties PCI-DAS1002 - page 20

    PCI-DAS1002 User's Manual Specifications Analog output Table 6. Analog output specifications D/A converter type AD7847AR or equivalent Resolution 12 bits Number of channels 2 Configuration Voltage output, single-ended Output range ±10 V, ±5 V, 0 to 10 V, or 0 to 5 V. Soft ware selectable . Each ch annel independently programmable. D/A pacing ...

  • Measurement Specialties PCI-DAS1002 - page 21

    PCI-DAS1002 User's Manual Specifications Counters Table 9. Counter specific ations Parameter Specification Counter type 82C54 Configuration Two 82C54 devices. 3 down counters per 82C54, 16 bits ea ch Counter 0 - ADC residual sample counter Source: ADC Clock Gate: Internal programmable source Output: End-of-Acquisition interrupt Counter 1 - ADC ...

  • Measurement Specialties PCI-DAS1002 - page 22

    PCI-DAS1002 User's Manual Specifications Digital input/output Table 10. DIO specifications Digital type 82C55 Number of I/O 24 (FIRSTPORTA Bit 0 through FIRSTPORTC Bit 7) 2 banks of 8 and 2 banks of 4 or 3 banks of 8 or Configuration 2 banks of 8 with handshake Input high voltage 2.0 V min, 5.5 V absolute max Input low voltage 0.8 V max, –0. ...

  • Measurement Specialties PCI-DAS1002 - page 23

    PCI-DAS1002 User's Manual Specifications Connector and pin out Table 16. Main connector specificatio ns Connector type 100-pin high-density Robinson Nugent Compatible cable C100FF-x, unshielde d ribbon cab le. x = length in feet Compatible accessory products (with C100FF-x cable) ISO-RACK16/P ISO-DA02/P CIO-ERB24 (DADP-5037 adaptor required) C ...

  • Measurement Specialties PCI-DAS1002 - page 24

    PCI-DAS1002 User's Manual Specifications 16-channel single-ended mode pin out Pin Signal Name Pin Signal Name 1 LLGND 51 FIRSTPORTA Bit 0 2 CH0 HI 52 FIRSTPORTA Bit 1 3 CH8 HI 53 FIRSTPORTA Bit 2 4 CH1 HI 54 FIRSTPORTA Bit 3 5 CH9 HI 55 FIRSTPORTA Bit 4 6 CH2 HI 56 FIRSTPORTA Bit 5 7 CH10 HI 57 FIRSTPORTA Bit 6 8 CH3 HI 58 FIRSTPORTA Bit 7 9 C ...

  • Measurement Specialties PCI-DAS1002 - page 25

    Declaration of Conformity Manufacturer: Measurement Computing C orporation Address: 10 Commerce Way Suite 1008 Norton, MA 02766 USA Category: Electrical equi pment for m easur ement, cont rol and laboratory use. Measurement Computing Corporation declares under sole respo nsibility that the product PCI-DAS1002 to which this declaration relates is in ...

  • Measurement Specialties PCI-DAS1002 - page 26

    Measurement Computing Cor poration 10 Comme rce Wa y Suite 1008 Norton, Massachusetts 02766 (508) 946-5100 Fax: (508) 946-9500 E-mail: info@mccdaq.com www.mccdaq.co m ...

Produzent Measurement Specialties Kategorie Network Card

Dokumente, die wir vom Produzenten des Geräts Measurement Specialties PCI-DAS1002 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Measurement Specialties
- Bedienungsanleitungen PCI-DAS1002
- Produktkarten Measurement Specialties
- Informationsbroschüren
- oder Energieetiketten Measurement Specialties PCI-DAS1002
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Measurement Specialties PCI-DAS1002.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Measurement Specialties PCI-DAS1002, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Measurement Specialties PCI-DAS1002. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Measurement Specialties PCI-DAS1002 ansehen.

Die komplette Bedienungsanleitung des Geräts Measurement Specialties PCI-DAS1002, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Measurement Specialties PCI-DAS1002 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Measurement Specialties PCI-DAS1002 verständlich ist.

Eine gänzliche Bedienungsanleitung von Measurement Specialties sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Measurement Specialties PCI-DAS1002 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Measurement Specialties PCI-DAS1002 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Measurement Specialties PCI-DAS1002, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Measurement Specialties PCI-DAS1002 - die uns die ersten Schritte während der Nutzung von Measurement Specialties PCI-DAS1002 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Measurement Specialties PCI-DAS1002 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Measurement Specialties PCI-DAS1002 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Measurement Specialties PCI-DAS1002?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Measurement Specialties PCI-DAS1002 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Measurement Specialties PCI-DAS1002 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)