Bedienungsanleitung Miller Electric NT 450, NT 500

44 Seiten 1.39 mb
Download

Zur Seite of 44

Summary
  • Miller Electric NT 450, NT 500 - page 1

    Dimension NT 450 Processes Description Multiprocess W elding Arc Welding Power Source OM-2252 218 084R 2008 − 01 t Visit our website at www.MillerWelds.com File: Multiprocess Welding Dimension NT 500 t And ...

  • Miller Electric NT 450, NT 500 - page 2

    Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual specification sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .Mille ...

  • Miller Electric NT 450, NT 500 - page 3

    T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2. Arc W elding Hazards 1 . . . . . . . ...

  • Miller Electric NT 450, NT 500 - page 4

    Notes ...

  • Miller Electric NT 450, NT 500 - page 5

    OM-2252 Page 1 SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _2007 − 04 7 Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage DANGER! − Indicates a hazardous situation which, if not avoided, will result in death or serious injury . The possible hazards are shown in the adjoining symbols or ...

  • Miller Electric NT 450, NT 500 - page 6

    OM-2252 Page 2 W elding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health. FUMES AND GASES can be hazardous.  Keep your head out of the fumes. Do not breathe the fumes.  If inside, ventilate the area and/or use local forced ventilation at the arc to remove welding fumes and gases.  If ventilation is ...

  • Miller Electric NT 450, NT 500 - page 7

    OM-2252 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard.  Do not install or place unit on, over , or near combustible surfaces.  Do not install unit near flammables.  Do not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this un ...

  • Miller Electric NT 450, NT 500 - page 8

    OM-2252 Page 4 1-4. California Proposition 65 W arnings W elding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause birth defects and, in some cases, cancer . (California Health & Safety Code Section 25249.5 et seq.) Battery posts, terminals and related accessories contain lead and lea ...

  • Miller Electric NT 450, NT 500 - page 9

    OM-2252 Page 5 SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE A V ANT UTILISA TION fre_som_2007 − 04 7 Se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes. 2-1. S ym bol es u t ilisés DANGER! − Indique une situation dangereuse qui si on l’évite pas peut donner la mort ou des blessures graves ...

  • Miller Electric NT 450, NT 500 - page 10

    OM-2252 Page 6 Il reste une TENSION DC NON NÉGLIGEABLE dans les sources de soudage onduleur quand on a coupé l’alimentation.  Arrêter les convertisseurs, débrancher le courant électrique et décharger les condensateurs d’alimentation selon les instructions indiquées dans la partie Entretien avant de toucher les pièces. DES PIÈCES CHA ...

  • Miller Electric NT 450, NT 500 - page 11

    OM-2252 Page 7 LES ACCUMULA TIONS DE GAZ risquent de provoquer des blessures ou même la mort.  Fermer l’alimentation du gaz protecteur en cas de non-utilisation.  V eiller toujours à bien aérer les espaces confi- nés ou se servir d’un respirateur d’adduction d’air homologué. LES CHAMPS MAGNETIQUES peuv- ent affecter des implants ...

  • Miller Electric NT 450, NT 500 - page 12

    OM-2252 Page 8 LES FILS DE SOUDAGE peuvent provoquer des blessures.  Ne pas appuyer sur la gâchette avant d’en avoir reçu l’instruction.  Ne pas diriger le pistolet vers soi, d’autres per- sonnes ou toute pièce mécanique en enga- geant le fil de soudage. DES ORGANES MOBILES peuvent provoquer des blessures.  S’abstenir de touche ...

  • Miller Electric NT 450, NT 500 - page 13

    OM-2252 Page 9 2-5. P r i nc ip al e s n or m e s d e sé c ur i té Safety i n W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, de Global Engineering Documents (téléphone : 1-877-413-5184, site Internet : www .global.ihs.com). Recommended Safe Practices for the Preparation for W elding and Cut- ting of Containers and Piping , Americ ...

  • Miller Electric NT 450, NT 500 - page 14

    OM-2252 Page 10 ...

  • Miller Electric NT 450, NT 500 - page 15

    OM-2252 Page 1 1 SECTION 3 − DEFINITIONS 3-1. General Precautionary Label W arning! Watch Out! There are possible hazards as shown by the symbols. 1 Electric shock from welding electrode or wiring can kill. 1.1 W ear dry insulating gloves. Do not touch electrode with bare hand. Do not wear wet or damaged gloves. 1.2 Protect yourself from electric ...

  • Miller Electric NT 450, NT 500 - page 16

    OM-2252 Page 12 3-2. Input Connection Label 1 W arning! W atch Out! There are possible hazards as shown by the symbols. 2 Electric shock from wiring can kill. 3 Disconnect input plug or power before working on machine. 4 Read the Owner ’ s Manual before working on this machine. 5 Consult rating label for input power requirements, and check power ...

  • Miller Electric NT 450, NT 500 - page 17

    OM-2252 Page 13 SECTION 4 − INST ALLA TION 4-1. Specifications Model Rated W elding Amperage/ V oltage Range Max OCV − DC Amperes Input at Rated Load Output 50/60 Hz, Three-Phase Model W elding Output V oltage Range Max OCV − DC 230 V 380 V 400 V 440 V 460 V 575 V KV A KW 450 Amp 450 A @ 38 V olts DC 100% 5 − 500A In CC Mode 78 VDC In CC Mo ...

  • Miller Electric NT 450, NT 500 - page 18

    OM-2252 Page 14 4-3. V olt-Ampere Curves V olt-ampere curves show mini- mum and maximum voltage and amperage output capabilities of unit. Curves of other settings fall be- tween curves shown. va_curve1 − 4/95 − 212 1 11-A / 212 1 12-A A. CC Mode B. CV Mode 0 10 20 30 40 50 60 70 80 90 0 100 20 0 30 0 40 0 500 600 70 0 80 0 DC Current DC V oltag ...

  • Miller Electric NT 450, NT 500 - page 19

    OM-2252 Page 15 4-4. Selecting A Location 1 Lifting Eye 2 Lifting Forks Use lifting eye or lifting forks to move unit. If using lifting forks, extend forks beyond opposite side of unit. 3 Plate Label 4 Rating Label CE Models − T ypical Use rating label to determine input power needs. 5 Line Disconnect Device Locate unit near correct input pow- er ...

  • Miller Electric NT 450, NT 500 - page 20

    OM-2252 Page 16 4-5. Dimensions And Weights Dimensions A 30 in (762 mm) including lift eye B 23 in (585 mm) C 38 in (966 mm) including strain relief D 35 in (889 mm) E 1-1/4 in (32 mm) F 21-1/8 in (537 mm) G 1-1/8 in (29 mm) H 7/16 in (1 1 mm) Dia W eight 376 lb (171 kg) 800 453-A / 801 530 D E F G H 4 Holes A B C Front ...

  • Miller Electric NT 450, NT 500 - page 21

    OM-2252 Page 17 4-6. Tipping ! Do not move or operate unit where it could tip. 4-7. 1 15 V AC Receptacle And Circuit Breakers Ref. 800 166-D ! T urn Off power before connecting to receptacle. 1 1 15 V 15 A AC Receptacle RC15 Power is shared between RC15 and Remote 14 receptacle RC14 (see Section 4-1 1). 2 Circuit Breaker CB1 3 Circuit Breaker CB2 C ...

  • Miller Electric NT 450, NT 500 - page 22

    OM-2252 Page 18 4-8. W eld Output T erminals And Selecting Cable Sizes ! T urn Off power before T otal Cable (Copper) Length In Weld Circuit Not Exceeding ! T urn Off power b e f ore connecting to weld output terminals. 100 ft (30 m) Or Less 150 ft (45 m) 200 ft (60 m) 250 ft (70 m) 300 ft (90 m) 350 ft (105 m) 400 ft (120 m) W elding Amperes 10 ? ...

  • Miller Electric NT 450, NT 500 - page 23

    OM-2252 Page 19 4-10. Remote 14 Receptacle Information Socket* Socket Information 24 VOL TS AC A 24 volts ac. Protected by circuit breaker CB2. B Contact closure to A completes 24 volts ac contactor control circuit. 1 15 VOL TS AC I 1 15 volts ac. Protected by circuit breaker CB1. J Contact closure to I completes 1 15 volts ac contactor control cir ...

  • Miller Electric NT 450, NT 500 - page 24

    OM-2252 Page 20 4-12. Electrical Service Guide Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommenda- tions are for a dedicated branch circuit sized for the rated output and duty cycle of the welding power source. 50/60 Hertz Models Input V oltage 230 380 400 440 460 575 Inp ...

  • Miller Electric NT 450, NT 500 - page 25

    OM-2252 Page 21 4-14. Connecting Input Power 1/2 in 3/8 in T ools Needed: 800 103-C / Ref. 801 1 16-A ! Installation must meet all National and Local Codes − have only quali- fied persons make this installation. ! Disconnect and lockout/tagout in- put power before connecting input conductors from unit. ! Make input power connections to the weldin ...

  • Miller Electric NT 450, NT 500 - page 26

    OM-2252 Page 22 SECTION 5 − OPERA TION 5-1. Controls 229 448-A 1 2 3 6 7 4 5 1 Power Switch  This unit is equipped with a fan motor that is thermostatically controlled and only runs when cooling is needed. 2 V oltmeter (see Section 5-2) 3 Ammeter (see Section 5-2) 4 Mode Switch Use Mode switch to determine both process and output On/Of f contr ...

  • Miller Electric NT 450, NT 500 - page 27

    OM-2252 Page 23 5-2. Meter Functions For CC/CV Models  The meters display the actual weld output values for approximately three seconds after the arc is broken. Mode Meter Reading At Idle Scratch Start TIG Actual V olts (OCV) Preset Amps VA 78.0 85 Lift-Arc TIG (GT AW) VA Actual V olts Preset Amps 8.0 85 Air Carbon Arc VA Actual V olts (OCV) Pre ...

  • Miller Electric NT 450, NT 500 - page 28

    OM-2252 Page 24 SECTION 6 − MAINTENANCE & TROUBLESHOOTING 6-1. Routine Maintenance  Maintain more often during severe conditions. ! Disconnect power before maintaining.  = Check  = Change  = Clean Δ = Repair  = Replace * T o be done by Factory Authorized Service Agent Every 3 Months  Labels  W eld T erminals Every ...

  • Miller Electric NT 450, NT 500 - page 29

    OM-2252 Page 25 6-3. V oltmeter/Ammeter Help Displays  All directions are in reference to the front of the unit. All circuitry referred to is located inside the unit. 1 Help 0 Display Indicates a shorted thermistor in the transformer of the unit. If this display is shown, contact a Factory Autho- rized Service Agent. 2 Help 2 Display Indicates a ...

  • Miller Electric NT 450, NT 500 - page 30

    OM-2252 Page 26 6-4. T roubleshooting T rouble Remedy No weld output; unit completely inop- erative; pilot light PL1 off. Place line disconnect device in On position (see Section 4-14 ). Check for open line fuse(s), and replace if open (see Section 4-14 ). Check for proper input power connections (see Section 4-14 ). Check for proper jumper link po ...

  • Miller Electric NT 450, NT 500 - page 31

    OM-2252 Page 27 Notes W or k l i k e a P r o ! Pros wel d and cut safel y . Read the safety rules at the beginni ng of this manual . ...

  • Miller Electric NT 450, NT 500 - page 32

    OM-2252 Page 28 SECTION 7 − ELECTRICAL DIAGRAM Figure 7-1. Circuit Diagram For Dimension NT ...

  • Miller Electric NT 450, NT 500 - page 33

    OM-2252 Page 29 218 081-F ...

  • Miller Electric NT 450, NT 500 - page 34

    OM-2252 Page 30 SECTION 8 − P ARTS LIST 803 896-E  Hardware is common and not available unless listed. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 3 2 15 17 18 19 20 21 24 25 26 27 28 29 31 30 16 22 23 21 Figure 8-1. Main Assembly Description Part No. Dia. Mkgs. Item No. Figure 8-1. Main Assembly Quantity 1 Fig 8-2 P ANEL, Front w/Components 1 . . . . . ...

  • Miller Electric NT 450, NT 500 - page 35

    OM-2252 Page 31 Description Part No. Dia. Mkgs. Item No. Figure 8-1. Main Assembly (Continued) Quantity 14 TE1 159 244 PRIMARY BOX (Includes), 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 601 835 NUT , 10-32 BRASS 24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric NT 450, NT 500 - page 36

    OM-2252 Page 32 803 897-G  Hardware is common and not available unless listed.  Hardware is common and not available unless listed. 1 2 3 4 5 3 4 7 6 8 9 10 22 24 22 18 19 20 21 23 13 14 15 12 11 16 25 26 27 28 29 Figure 8-2. Panel, Front With Components ...

  • Miller Electric NT 450, NT 500 - page 37

    OM-2252 Page 33 Figure 8-2. Panel, Front With Components (Fig 8-1 Item 1) Description Quantity Part No. Dia. Mkgs. Item No. 1 204 143 P ANEL, FRONT 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 POS 181 245 TERMINAL, PWR OUTPUT RED 1 . . . . . . . . . . . . . ...

  • Miller Electric NT 450, NT 500 - page 38

    OM-2252 Page 34  Hardware is common and not available unless listed. 803 937-C 1 2 2 3 4 5 6 9 10 11 12 7 13 8 14 Figure 8-3. IGBT/Capacitor Assembly ...

  • Miller Electric NT 450, NT 500 - page 39

    OM-2252 Page 35 Description Part No. Dia. Mkgs. 221 298 Item No. Quantity Figure 8-3. IGBT/Capacitor Assembly (Fig 8-1 item 23) 1 221 301 BUS PLA TE, IGBT TO CAP ACITOR NEGA TIVE 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 221 304 ST AND − OFF , CONDUCTIVE BUS 5 . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric NT 450, NT 500 - page 40

    OM-2252 Page 36  Hardware is common and not available unless listed. 1 803 936-A 2 3 4 5 6 9 7 8 10 Figure 8-4. Panel, Rear With Components Figure 8-4. Panel, Rear With Components (Fig 8-1 Item 9) Description Quantity Part No. Dia. Mkgs. Item No. 1 173 283 CHAMBER, PLENUM 14 IN 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric NT 450, NT 500 - page 41

    Notes ...

  • Miller Electric NT 450, NT 500 - page 42

    Notes W or k l i k e a P r o ! Pros wel d and cut safel y . Read the safety rules at the beginni ng of this manual . ...

  • Miller Electric NT 450, NT 500 - page 43

    Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 2007 − 01 Y our distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor . The expe ...

  • Miller Electric NT 450, NT 500 - page 44

    PRINTED IN USA © 2007 Miller Electric Mfg. Co. 2007 − 01 Miller Elect ric Mfg. Co. An Illinois T ool Wo rks Compan y 1635 West S pencer S treet Applet on, WI 5 4914 US A International He adquarter s − US A USA Phone: 920-735-4505 Aut o-At tended USA & Canada F AX : 920-735-4134 Int ernati onal F AX: 9 20-735-4125 European Headqua rters − ...

Produzent Miller Electric Kategorie Welder

Dokumente, die wir vom Produzenten des Geräts Miller Electric NT 450, NT 500 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Miller Electric
- Bedienungsanleitungen NT 450, NT 500
- Produktkarten Miller Electric
- Informationsbroschüren
- oder Energieetiketten Miller Electric NT 450, NT 500
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Miller Electric NT 450, NT 500.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Miller Electric NT 450, NT 500, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Miller Electric NT 450, NT 500. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Miller Electric NT 450, NT 500 ansehen.

Die komplette Bedienungsanleitung des Geräts Miller Electric NT 450, NT 500, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Miller Electric NT 450, NT 500 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Miller Electric NT 450, NT 500 verständlich ist.

Eine gänzliche Bedienungsanleitung von Miller Electric sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Miller Electric NT 450, NT 500 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Miller Electric NT 450, NT 500 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Miller Electric NT 450, NT 500, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Miller Electric NT 450, NT 500 - die uns die ersten Schritte während der Nutzung von Miller Electric NT 450, NT 500 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Miller Electric NT 450, NT 500 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Miller Electric NT 450, NT 500 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Miller Electric NT 450, NT 500?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Miller Electric NT 450, NT 500 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Miller Electric NT 450, NT 500 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)