Bedienungsanleitung Desa VFP18MV

24 Seiten 0.57 mb
Download

Zur Seite of 24

Summary
  • Desa VFP18MV - page 1

    Save this manual for future reference. UNVENTED (VENT -FREE) PROP ANE/LP GAS LOG HEA TER ALSO DESIGN-CER TIFIED AS A VENTED DECORA TIVE APPLIANCE OWNER’S OPERA TION AND INST ALLA TION MANUAL LO PILOT OFF HI VFP18MV VFP24MV VFP30MV V ariable Manually- Controlled WARNING: If the information in this manual is not followed exactly, a fire or explosio ...

  • Desa VFP18MV - page 2

    2 105071 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. SAFETY INFORMA TION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be work- ing properly. Get fresh ...

  • Desa VFP18MV - page 3

    3 105071 OWNER’S MANUAL PRODUCT IDENTIFICA TION Figure 1 - Ember Master Front Logs PRODUCT FEA TURES UNP ACKING 1. Remove logs and heater base assem- bly from carton. Note: Do not pick up heater base assembly by burners. This could damage heater . Always handle base assembly by grate. 2. Remove all protective packaging ap- plied to logs and heate ...

  • Desa VFP18MV - page 4

    4 105071 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. Confined and Unconfined Space The National Fuel Gas Code, ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m 3 per kw) of the aggre- gate input rating of all appliances installed in that space and an unconfin ...

  • Desa VFP18MV - page 5

    5 105071 OWNER’S MANUAL DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the ro ...

  • Desa VFP18MV - page 6

    6 105071 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" ...

  • Desa VFP18MV - page 7

    7 105071 OWNER’S MANUAL INSTALLATION AND CLEARANCES (Vent-Free Operation Only) WARNING: Maintain the mini- mum clearances. If you can, pro- vide greater clearances from floor, ceiling, and adjoining wall. INST ALLA TION WARNING: A qualified ser- vice person must install heater. Follow all local codes. WARNING: Before installing in a solid fuel bu ...

  • Desa VFP18MV - page 8

    8 105071 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. Heat Resistant Material (A) INST ALLA TION Continued Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace Noncombustible Requirements for Material Distance (A) Safe Installation 12" or more Noncombustible material OK. Between 8" and 12&qu ...

  • Desa VFP18MV - page 9

    9 105071 OWNER’S MANUAL Continued Figure 6 - Minimum Mantel Clearances Without Using Hood MANTEL CLEARANCES In addition to meeting noncombustible mate- rial clearances, you must also meet required clearances between fireplace opening and mantel shelf. If you do not meet the clear- ances listed below, you will need a hood. Determining Minimum Mant ...

  • Desa VFP18MV - page 10

    10 105071 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION Note: When used as a vented heater, appli- ance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of noncombustible material. If your heater is a manually-controlled model, yo ...

  • Desa VFP18MV - page 11

    11 105071 OWNER’S MANUAL INST ALLA TION Continued Continued WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas. CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater ...

  • Desa VFP18MV - page 12

    12 105071 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. Pressure Testing gas Supply Piping system Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas sup- ply piping. Pressures in excess of 1/2 psig will damage heater regul ...

  • Desa VFP18MV - page 13

    13 105071 OWNER’S MANUAL WARNING: Failure to posi- tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in prop- erty damage or personal injury. INSTALLING LOGS INST ALLA TION Continued Bottom Middle Log (#2) Metal Post Metal Post Groove Groove Grate Figure 18 - Installing ...

  • Desa VFP18MV - page 14

    14 105071 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. 4. W ait fi ve (5) minutes to clear out any gas. Then smell f or gas, including near the floor . If you smell gas, STOP! F ollow “B” in the safety in- formation, column 1. If you don’ t smell gas, go to the next step. 5. Press in contr ol knob and tur n coun- tercloc ...

  • Desa VFP18MV - page 15

    15 105071 OWNER’S MANUAL WARNING: Do not operate heater between locked positions. CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve. The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even the lowest setting provid ...

  • Desa VFP18MV - page 16

    16 105071 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burners, and cir- culating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied se ...

  • Desa VFP18MV - page 17

    17 105071 OWNER’S MANUAL TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit ...

  • Desa VFP18MV - page 18

    18 105071 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. TROUBLESHOOTING Continued OBSERVED PROBLEM One or both burners do not light after ODS/ pilot is lit Delayed ignition of one or both burners Burner backfiring during combustion Yellow flame in front burner during burner combustion Slight smoke or odor during initial operati ...

  • Desa VFP18MV - page 19

    19 105071 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot re ...

  • Desa VFP18MV - page 20

    20 105071 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. ILLUSTRA TED PA R T S BREAKDOWN VFP18MV VFP24MV VFP30MV 17 19 18 25 24 20 20 26 27 28 6 7 27 27 24 9 8 10 11 12 14 21 22 26-1 26-2 23 6-1 6-2 13 15 16 4 5 3 2 1R 1L ...

  • Desa VFP18MV - page 21

    21 105071 OWNER’S MANUAL This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 22 of this manual. P ARTS LIST VFP18MV VFP24MV VFP30MV KEY PART NUMBER FOR NO. VFP18MV VFP24MV VFP30MV DESCRIPTION QTY. 1L 105241-01 105241-02 105998-01 Left Front Log (#1L) 1 1R __ ...

  • Desa VFP18MV - page 22

    22 105071 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INC. ACCESSORIES Purchase these heater accessories from your local dealer. If they can not supply these accessories, call Fireplace Manufacturers Incorporated’s Parts Department at 1-800- 888-2050 for referral information. You can also write to the address listed on the back ...

  • Desa VFP18MV - page 23

    23 105071 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________ ...

  • Desa VFP18MV - page 24

    KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. Model Serial No. Date Purchased LIMITED ...

Produzent Desa Kategorie Electric Heater

Dokumente, die wir vom Produzenten des Geräts Desa VFP18MV erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Desa
- Bedienungsanleitungen VFP18MV
- Produktkarten Desa
- Informationsbroschüren
- oder Energieetiketten Desa VFP18MV
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Desa VFP18MV.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Desa VFP18MV, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Desa VFP18MV. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Desa VFP18MV ansehen.

Die komplette Bedienungsanleitung des Geräts Desa VFP18MV, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Desa VFP18MV hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Desa VFP18MV verständlich ist.

Eine gänzliche Bedienungsanleitung von Desa sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Desa VFP18MV bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Desa VFP18MV befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Desa VFP18MV, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Desa VFP18MV - die uns die ersten Schritte während der Nutzung von Desa VFP18MV erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Desa VFP18MV hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Desa VFP18MV im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Desa VFP18MV?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Desa VFP18MV nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Desa VFP18MV hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)