  • Faber Remote Blower - page 1

    Instruction Manual READ AND SA VE THESE INSTRUCTIONS The Installer must leave these instructions with the homeowner . The homeowner must keep these instructions for future reference and for local electrical inspectors’ use. Concept Remote Blower ...

  • Faber Remote Blower - page 2

    2 EN CONTENTS WARNING 3 CHARACTERISTICS 5 INST ALLA TION 8 USE 13 MAINTENANCE 1 4 ...

  • Faber Remote Blower - page 3

    3 EN READ THESE INSTRUCTIONS BEFORE YOU ST ART INST ALLING THIS RANGEHOOD READ AND SA VE THESE INSTRUCTIONS W ARNING: - T O REDUCE THE RISK OF A RANGE T OP GREASE FIRE : Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium setting. Always turn hood ON ...

  • Faber Remote Blower - page 4

    4 EN This appliance should be connected directly to the fused disconnect (or circuit breaker) through flexible, armored or nonmetallic sheathed copper cable. Allow some slack in the cable so the appliance can be moved if servicing is ever necessary . A UL Listed, 1/2" con duit connector must be provided at each end of the power supply cable (a ...

  • Faber Remote Blower - page 5

    5 EN 1 3 4 5 10 11 12 13 G E F D C A 2 CHARACTERISTICS Components Q.ty 1 1 Hood Body , complete with: Blower, Filters, Controls 2 1 Built-in hood body case 3 1 Rear remote motor connection panel 4 1 T op air outlet flange with valve 5 1 T op air outlet plug 10 1 Light 11 4 Support arms 12 2 Bush masking plug 13 2 Arm support bush A 10 Screws 3,5 x ...

  • Faber Remote Blower - page 6

    6 EN Dimensional chart - Hood Distance from the Hob ...

  • Faber Remote Blower - page 7

    7 EN Dimensional chart - LIGHT ...

  • Faber Remote Blower - page 8

    8 EN INST ALLA TION The hood can be installed in the following ways: top air outlet, bottom air outlet, rear air outlet. Once the desired configuration has been chosen (see the diagrams below) it will be necessary to provide an opening in the wall where to house the built-in hood body case. Besides the air ducting pipes, basing on the chosen config ...

  • Faber Remote Blower - page 9

    9 EN LIGHTING UNIT INST ALLA TION SCHEME LIGHTING UNIT LOWER BORDER SHALL BE INST ALLED A T THE MINIMUM DIST ANCE OF 34 9/16 IN. ABOVE THE COOKING SURF ACE. W ith the aid of the drilling template provided mark the necessary holes and drill them. ø15/16 TO P OR BOTTOM AIR OUTLET CONFIGURA TION The hood is manufactured with the air outlet at the top ...

  • Faber Remote Blower - page 10

    10 EN REAR AIR OUTLET CONFIGURA TION • Remove the suction panel by unfastening the 8 screws around the frame. • Remove the metal grease filters. • Remove the metal profile fixed to the flange by unfastening the 5 screws. • Fit the air outlet plug into the top air outlet. • Remove the rear air outlet plug . Built-in hood body case installa ...

  • Faber Remote Blower - page 11

    11 EN Hood body installation • In case of the bottom air outlet configuration the hood body has to be turned 180°. • Remove the top cover of the terminal box by unfastening the two screws fixing it to the hood casing. • W ith the aid of pliers brake through a hole inside the terminal box providing thus for a passage of the electrical connect ...

  • Faber Remote Blower - page 12

    12 EN Lighting unit installation • Provide for passage of the electrical connection wires with the hood body . • Slide the top cover downwards, unfastening the two side screws and taking care not to scratch the tubular support members. • Insert the 4 plugs D into the earlier drilled holes. • Decide the height of the light; loosen the grub s ...

  • Faber Remote Blower - page 13

    13 EN Electrical connection ELECTRICAL SHOCK HAZARD • Disconnect power before making electrical connctions. • Connect ground wire to green ground screw in terminal box. ! W ARNING green ground screw hood wiring purple wiring red wiring hood wiring black wiring white wiring power supply conduit light wiring exterior blower wiring twist-on connec ...

  • Faber Remote Blower - page 14

    14 EN MAINTENANCE Grease filters CLEANING MET AL GREASE FIL TERS • Alarm signal reset • Switch off the lights and extractor motor . • Press button T3 for at least 3 seconds, until the leds start to flash. Cleaning the filters • Open the suction cover using the lever provided. • The filters are washable and must be cleaned when the Led S1 ...

  • Faber Remote Blower - page 15

    15 EN Electric Diagram Lighting LIGHT REPLACEMENT 20 W halogen light. • Extract the lamp from the Support. • Replace with another of the same type, making sure that the two pins are properly inserted in the lamp holder socket holes. ...

  • Faber Remote Blower - page 16

    436002499_02 - 041 103 ...

Produzent Faber Kategorie Blower

Dokumente, die wir vom Produzenten des Geräts Faber Remote Blower erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Faber
- Bedienungsanleitungen Remote Blower
- Produktkarten Faber
- Informationsbroschüren
- oder Energieetiketten Faber Remote Blower
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Faber Remote Blower.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Faber Remote Blower, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Faber Remote Blower. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Faber Remote Blower ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Faber Remote Blower, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Faber Remote Blower hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Faber Remote Blower verständlich ist.

Eine gänzliche Bedienungsanleitung von Faber sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Faber Remote Blower bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Faber Remote Blower befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Faber Remote Blower, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Faber Remote Blower - die uns die ersten Schritte während der Nutzung von Faber Remote Blower erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Faber Remote Blower hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Faber Remote Blower im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Faber Remote Blower?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Faber Remote Blower nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Faber Remote Blower hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)