  • Tektronix VM700T - page 1

    VM700 T (turbo) V ideo Measurement Set Option 11 P AL V ideo Measurements M any capabilities in one instrument – Digitizing waveform monitor – Digitizing vectorscope – Picture Display – Group delay and frequency response – Noise measurement set – Automatic measurement set Auto mode – Unattended monitoring of P AL video signals from st ...

  • Tektronix VM700T - page 2

    modem to report measurement r esults or control a signal router . A relative to reference mode allows normalizing to a signal source or eliminate signal path errors from the desired measurement. Up to 2 video references can be stored in NVRAM. Additionally , a f te r downloading to a PC through the V M700T FTP driver , the video reference can be up ...

  • Tektronix VM700T - page 3

    Vertical interval test signals can be seen very clearly for additional analysis of the signal. These can be printed as support documentation for automatic measurement results. E ven a single horizontal synchronization pulse can be displayed at a high intensity . 0.5 0.0 Volts Sound-In-Sync Off Sound-In-Sync Off Precision Mode On Precision Mode On L ...

  • Tektronix VM700T - page 4

    Bar Line Time measurement. Chrominance to Luminance Gain and Delay measurement. MEASURE MODE 1,2 BAR LINE TIME A bsolute Relative M easurement Range Mode Mode Accuracy Accuracy B ar Level (b1 or Back Porch) 300 mV to 1.4 V ± 0.5% ± 0.2% S ync Level 50 mV to 600 mV ± 0.5% ± 0.2% S ync to Bar T op 350 mV to 2 V ± 0.5% ± 0.2% S ync/Bar Ratio 10% ...

  • Tektronix VM700T - page 5

    Chrominance Non-Linearity measurement. Color Bar measurement. Luminance Level (mV ) Luminance Level (mV ) Chrominance Level (mV ) Chrominance Level (mV ) Chrominance Phase (deg) Chrominance Phase (deg) Gray Gray Yellow Yellow Cyan Cyan Green Green Magenta Magenta Red Red Blue Blue Black Black 0.0 500.0 1000.0 0.0 500.0 1000.0 0.0 500.0 1000.0 0.0 5 ...

  • Tektronix VM700T - page 6

    Frequency Response and Group Delay measurement using Sin X/X. Horizontal Timing measurement. M EASURE MODE (continued) FREQUENCY RESPONSE AND GROUP DELA Y A bsolute Relative M easurement Range Mode Mode A ccuracy Accuracy F requency Response to 5 MHz ± 40 dB ± 1.0 dB ± 0.3 dB to 6 MHz ± 40 dB ± 2.0 dB ± 0.6 dB Group Delay to 5 MHz ± 1.0 µs ...

  • Tektronix VM700T - page 7

    LINE FREQUENCY M easurement Range Accuracy L ine Frequency ± 3% ± 0.1% F ield Frequency ± 3% ± 0.1% LUMINANCE NON-LINEARITY Absolute Relative M easurement Range Mode Mode A ccuracy Accuracy L uminance Non-Linearity 0 to 100% ± 0.4% ± 0.2% K-factor measurement. Luminance Non-Linearity measurement. Luminance Non Linearity (%) Luminance Non Line ...

  • Tektronix VM700T - page 8

    VERTICAL BLANKING M easurement Range Absolute Mode Accuracy E qualizing Pulse Width 80 ns to 1 µs ± 10 ns B road Pulse Width 80 ns to 1 µs ± 10 ns V ertical Blanking Field 1 19 to 30 lines NA Vertical Blanking Field 2 19 to 30 lines NA Noise Spectrum measurement. V e rtical Blanking display . M EASURE MODE (continued) NOISE SPECTRUM M easuremen ...

  • Tektronix VM700T - page 9

    AMPLITUDE AND PHASE MEASUREMENTS (continued) M easurement Range Accuracy ITS Element Standard D ifferential Gain 0 to +100% ± 0.3% D2 CCIR Rec. 569 ( Peak and p-p) (0% nominal) D ifferential Phase 0 to 360 deg ± 0.3 deg D2 CCIR Rec. 569 (Peak and p-p) (0 deg nominal) FREQUENCY RESPONSE MEASUREMENTS M easurement Range Accuracy ITS Element Standard ...

  • Tektronix VM700T - page 10

    Unified Unweighted filter response curve per CCIR Recommendation 567. 0 –5 5 08 M Hz d BV –5 – 10 – 15 –2 0 –2 5 –3 0 –3 5 –4 0 – 45 –5 0 1 234 5 67 U nified Luminance weighted filter response curve per CCIR Recommendation 567. 0 – 14 05 MHz dBV .5 1 1.5 2 3 4 –12 – 10 –8 – 6 –4 – 2 2.5 3.5 4.5 Chrominance Weight ...

  • Tektronix VM700T - page 11

    Measur ement r esults are displayed in an easy-to-read format indicating the time, signal source, measurement, and whether the measured value exceeded caution (*) or alarm (**) limits. 11 VM700T Video Measurement Set C hannel A System Def ault 07-A ug-96 19:06:58 VM700T Video Measurement Set System Default Violated Limits Lower Upper Source ID ---- ...

  • Tektronix VM700T - page 12

    Measurement methods The following paragraphs specify the methods for each Option 11 measurement. Where appropriate, reference is made to the relevant CCIR recommendation. Line blanking timing measurements Color Burst Duration: Measured between the half-amplitude points of the burst chrominance envelope. Result expressed as the number of cycles betw ...

  • Tektronix VM700T - page 13

    Other timing measurements B ar Rise T ime: M easured between the 10% and 90% points on the leading edge of bar . See element B2. A mplitude and phase measurements Sync Amplitude Error: Measured as the difference b etween the sampled sync pulse amplitude and a nominal 300 mV amplitude. Result expressed as a % of the nominal 3 00 mV . Sign is positiv ...

  • Tektronix VM700T - page 14

    C/L Gain Inequality: Measured as the difference between the sampled peak-to-peak ampli- tude of the 700 mV (nominal) chrominance packet (G1 or G2) and the sampled amplitude of the luminance bar (also nomi- nally 700 mV). Result expressed as a % of sampled bar amplitude. Sign is positive if the chromi- nance amplitude is greater than the luminance a ...

  • Tektronix VM700T - page 15

    Frequency response measurements M ultiburst Flag Amplitude: Measured from the center point of the flag top to the ensuing bottom of the flag. Result e xpressed as % of sampled bar a mplitude. See element C1 and CCIR Recommendation 567. M ultiburst Amplitude (five packets): Measured as the peak-to-peak amplitude of each of the first five multiburst ...

  • Tektronix VM700T - page 16

    Contact T ektronix: A SEAN / Australasia / Pakistan ( 65) 6356 3900 A ustria + 41 52 675 3777 B alkan, Israel, South Africa and other ISE Countries + 41 52 675 3777 B elgium 0 7 81 60166 B razil & South America 5 5 (11) 3741-8360 Canada 1 (800) 661-5625 Central East Europe, Ukraine and Baltics +41 52 675 3777 Central Europe & Greece +41 52 ...

Produzent Tektronix Kategorie Stereo Receiver

Dokumente, die wir vom Produzenten des Geräts Tektronix VM700T erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Tektronix
- Bedienungsanleitungen VM700T
- Produktkarten Tektronix
- Informationsbroschüren
- oder Energieetiketten Tektronix VM700T
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Tektronix VM700T.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Tektronix VM700T, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Tektronix VM700T. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Tektronix VM700T ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Tektronix VM700T, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Tektronix VM700T hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Tektronix VM700T verständlich ist.

Eine gänzliche Bedienungsanleitung von Tektronix sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Tektronix VM700T bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Tektronix VM700T befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Tektronix VM700T, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Tektronix VM700T - die uns die ersten Schritte während der Nutzung von Tektronix VM700T erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Tektronix VM700T hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Tektronix VM700T im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Tektronix VM700T?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Tektronix VM700T nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Tektronix VM700T hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)