Bosch Appliances 125B LPS - page 1
WARNING : Improper installation, adjustment , alterat ion, service or maint enance can c ause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or t he gas supplier . Upon completion of the installation, these instructions should be handed to the user of the appli ...
-
Bosch Appliances 125B LPS - page 2
2 6 720 606 518 This well engineered, gas water heater has been specially designed to operate with incoming pre-heated water: It operates on the principle of heating water instantaneously “on demand”. When a hot water faucet is opened, cold water flows through the coils of the heat exchanger in the Aquast ar . This same flow opens the gas valve ...
-
Bosch Appliances 125B LPS - page 3
3 6 720 606 518 D861_059 M I N I M U M I N S T ALLA TI ON C LE A R ANC ES F RO M C OM B U S TI B LE AN D N O N C OM B U S TI B LE MA TE R IALS F O R AL COVE O R C L O S ET I NST ALLA TI O NS F RO NT VI EW S I DE VI EW A QUAST AR MO DE L 1 25B S MODEL 125BS TOP (A) 12 " FRONT (B) 4 " BACK 0 " SIDES 4 " FLOOR (C) 12 " VENT DI ...
-
Bosch Appliances 125B LPS - page 4
4 6 720 606 518 PR OPER L OCA TION FOR I NST ALL I NG Y OU R HEA T ER C arefully select the location of your new heater. For your safety and for proper heater operation, you must provide an abundant supply of combustion air and a proper venting installation. The heater may still operate even when improperly vented. It will, however , be less effici ...
-
Bosch Appliances 125B LPS - page 5
5 6 720 606 518 WARNING: Flammable materials, gasoline, pressurized containers, or any other items or articles that are pot entially fire hazards must NOT be placed on or adjacent to the heater. T he appliance area must be kept free of all combustible materials, gasoline and other flammable vapors and liquids. COMBUSTION AIR REQUIREMENTS The AquaSt ...
-
Bosch Appliances 125B LPS - page 6
6 6 720 606 518 Fig. 1 - Mounting the Heater Fig. 2 - Incandescent Part icle T ray Illustrat ion The incandescent particle tray (shipped loose in the carton with the water heater) must be attached at the bottom of the water heater front cover at the time of installation. Use the screws provided. See figure 2 SUPPORT BOARD WALL STUDS 1” X 4 ” SP ...
-
Bosch Appliances 125B LPS - page 7
7 6 720 606 518 VENTING V ent pipe connect ion. W AR NI NG : Do not reduce t he vent pipe size . S ee Fig. 3 for high alt itude inst allations The heater must be vented to the outside following all local ordinances and specifications for installing a gas appliance vent or chimney . The heater must be located as close as practicable to a vertically ...
-
Bosch Appliances 125B LPS - page 8
8 6 720 606 518 MASO NRY CH I MN EY : Masonr y chimneys shall be built and inst alled in accordance with N F PS 2 1 1 or local codes . A minimum 5” diameter gas vent pipe ( metal double wall T ype B ), or an approved clay flue liner or a listed c himney lining system must be used when venting into a naturally drafting, internal masonr y chimney . ...
-
Bosch Appliances 125B LPS - page 9
9 6 720 606 518 Fig. 3 – V ent Adaptor for High Altit ude Inst allations 5” X 6 ” ADAPT O R US ED ON HIGH A L TI TUD E T o check the draft : Close all doors and windows to the outside. T urn on all appliances that force air out of the building . These include all exhaust/ventilation fans, furnaces, clothes dryers, wood burning stoves, etc. Op ...
-
Bosch Appliances 125B LPS - page 10
10 6 720 606 518 GAS CONNECTIONS and Gas Regulator NO TE: The Aquastar 1 25 B”S” is supplied wit h a gas pressure regulator that must be inst alled on t he heat er before attaching the gas supply line. See figure 5. Failure to install the gas regulator as shown in figure 5 will be a violation of CSA certificat ion of t he unit . T he regulator ...
-
Bosch Appliances 125B LPS - page 11
11 6 720 606 518 The water heater must be isolated from the gas supply piping system by closing the manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or more than 0.5 psig. The water heater , including the pressure regulator provided with it, must not be operated at gas supply pressures in e ...
-
Bosch Appliances 125B LPS - page 12
12 6 720 606 518 O PERA TIN G INST R U C T IONS Before proceeding with the operation of the heater make sure that the system is filled with water . Open the cold water inlet supply to the heater fully . Open a hot water faucet to permit the water to fill the heater and the piping and to eliminate the air trapped in the system Close the hot water fa ...
-
Bosch Appliances 125B LPS - page 13
13 6 720 606 518 Fig. 8 - Characteristic Pilot Flame 3mm Correct gap between pilot burner tip and piezo electrode tip Piezo Electrode Air screen filter 1 0mm 3/8” Piezo Electrode Thermocouple T o clean t he pilot burner and/ or the pilot orifice : T urn off the gas at the unit. Remove the cover of the heater . T o do so, remove incandescent parti ...
-
Bosch Appliances 125B LPS - page 14
14 6 720 606 518 If some burners have yellow flames while others have good flames, it is likely that dust, lint or spider webs have partially clogged the burner venturis. Contact a gas service person to clean the remove and clean the burners. Mineral S c ale Build-up : The AquaStars heater, when operated at lower temperatures settings, do not accum ...
-
Bosch Appliances 125B LPS - page 15
15 6 720 606 518 T o test the thermocouple , disconnect the thermocouple lead to the ECO. Insert a multi-meter probe into the thermocouple lead and attach or hold the other lead to the metal gas valve (DC common). Light the pilot flame and hold button, meter reading should be 24 mVDC or more. If the reading is 24 mVD C or more the thermocouple is g ...
-
Bosch Appliances 125B LPS - page 16
16 6 720 606 518 See specifications on page 2. Unlike storage tank water heaters, the burners of a tankless water heater must be very powerful to heat water instantaneously since they do this only at the time hot water is actually being used. It is therefore imperative that the gas pressure requirement be met exactly . Insufficient gas pressure wil ...
-
Bosch Appliances 125B LPS - page 17
17 6 720 606 518 1 . Heat exchanger 2. Pilot assembly 3 . Burner manifold gas pressure test nipple 4. Main gas burner 5. Pilot gas tubing 6. Gas valve 7 . Piezo igniter 8. Location of pressure tap screw 9 . W ater valve 1 0. Gas inlet gas pressure test nipple 5 1 4 7 9 3 10 6 2 8 Fig. 1 0 - Diagram of AquaStar 1 25 B S ...
-
Bosch Appliances 125B LPS - page 18
18 6 720 606 518 A Q 1 25 BS Fig. 1 1 - I NTER IO R COM P ONE NTS DIA G RAM AN D P ARTS LI S T ...
-
Bosch Appliances 125B LPS - page 19
19 6 720 606 518 Fig. 1 1 INTERIOR COMPONENTS DIAGRAM AN D P ARTS LIST 1 25B S 1 Cov er 8 705 421 033 2 Cap cover 8 703 304 011 3 Water connection gasket 8 710 103 043 4 Draf t div ertor 8 705 5 05 354 5 Hea t exch anger 8 705 4 06 189 6 Hot water pipe 8 700 705 431 7 Cold water pipe 8 700 705 294 8 Heat exchan ger w asher 8 710 103 045 9 Overhea t ...
-
Bosch Appliances 125B LPS - page 20
20 6 720 606 518 Fig. 1 2 - Flow chart of Aquast ar 1 25 BS ...
-
Bosch Appliances 125B LPS - page 21
21 6 720 606 518 LI M ITE D W AR R ANT Y Aquast ar General Aquastar water heaters are warranted by the Manufacturer ( B OSC H) through C ontrolled Energy Corp . C ontrolled Energy C orp. (C E C) will furnish a replacement heat exchanger and will furnish a replacement of any other part which fails in normal use and service within the applicable peri ...
-
Bosch Appliances 125B LPS - page 22
VU L C ANO T ermod omést icos S.A. Estrada de Cacia 380 1 - 8 56 Aveiro - P ORTUGAL Recycled paper 3 1 e g a p e e s E L B A T E C N A N E T N I A M R A E Y Y R E V S E R A E Y 2 Y R E V S E R A E Y 5 - 3 Y R E V E E V L A V R E T A W E T A C I R B U L † E V L A V R E T A W D L I U B E R † N E E R C S R E T L I F R E T A W T C E P S N I † Y ...
Haben Sie eine Frage bezüglich Bosch Appliances 125B LPS?
Nutzen Sie das untere Formular
Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Bosch Appliances 125B LPS nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Bosch Appliances 125B LPS hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.