Bedienungsanleitung Carrier AQUASNAP 30RA/RH

36 Seiten 0.58 mb
Download

Zur Seite of 36

Summary
  • Carrier AQUASNAP 30RA/RH - page 1

    30RA/RH “B” 30R Y/R YH “B” PRO-DIALOG Control Operation and maintenance instructions AQUASNAP ...

  • Carrier AQUASNAP 30RA/RH - page 2

    2 TABLE OF CONTENTS 1 - SAFETY CONSIDERATIONS ...................................................................................................... ............................................ 4 1.1 - General .................................................................................................................. ......................... ...

  • Carrier AQUASNAP 30RA/RH - page 3

    3 GENERAL LEGEND Each of the following drawings is replaced in the whole document by the corresponding explanation: Start/stop button Return key Down arrow Up arrow DEL T A T . Example: temperature difference between entering and lea ving heat exchanger temperatures means character is flashing The cover graphics ar e solely for illustration and for ...

  • Carrier AQUASNAP 30RA/RH - page 4

    4 1 - SAFETY CONSIDERATIONS 1.1 - General Installation, start-up and servicing of equipment can be hazardous if certain factors particular to the installation are not considered: operating pressures, presence of electrical components and voltages and the installation site (elevated plinths and built-up up structures). Only properly qualified instal ...

  • Carrier AQUASNAP 30RA/RH - page 5

    5 3 - HARDWARE DESCRIPTION 3.1 - General Figure 1 3.2 - Electrical supply to boards All boards, except the PD-RCPM board, are supplied from a common 24 V a.c. supply ref erred to earth. CAUTION: Maintain the correct polarity when connecting the power supply to the boards, otherwise the boards may be damaged. In the event of a power supply interrupt ...

  • Carrier AQUASNAP 30RA/RH - page 6

    6 3.6 - Connections at the user's terminal block 3.6.1 - General description The contacts below are available at the user's terminal block on the NRCP-BASE board (see figure 1). Some of them can only be used if the unit operates in remote operating type (rEM). The follo wing table summarises the connections a t the user’ s terminal bloc ...

  • Carrier AQUASNAP 30RA/RH - page 7

    7 Description Alarm relay output circuit A Alarm relay output circuit B Boiler relay output Contact 1: start/stop/heat/cool Contact 2: start/stop/heat/cool Contact 3: demand limit selection Contact 4: demand limit selection Contact 5: setpoint selection Control contact 6: setpoint selection User safety loop input Connection to CCN Connector/channel ...

  • Carrier AQUASNAP 30RA/RH - page 8

    8 3.6.2 - Volt-free contact on/off/cooling/heating without multiplexing If the automatic heating/cooling changeover function is not selected (see sections 4.3.11.3, 5.1 and 5.2) the operation of contacts 1 and 2 is as follows: OFF ON cooling ON heating Contact 1 Open Closed Closed Contact 2 - Open Closed Contact status not significant 3.6.3 - Volt- ...

  • Carrier AQUASNAP 30RA/RH - page 9

    9 MAIN INTERF A CE BUTTON NAME DESCRIPTION Menu P er mits the selection of a main menu. Each main menu is represented b y an icon. The icon is lit if active. Up arrow Permits scrolling through the menu items (in the two-digit display). If the modification mode is active this button aut horises increase of the v alue of any parameter. Down arrow Per ...

  • Carrier AQUASNAP 30RA/RH - page 10

    10 The summary interface (right hand section) includes a mimic diagram of the unit, together with push-buttons and LEDs. It gives quick access to the main operating parameters of the unit. SUMMARY INTERF ACE LEDs* LED INDICA TION WHEN LIT Green LED : The unit is authorised to start or is already running Red LED: - Lit: circuit A or unit shut do wn ...

  • Carrier AQUASNAP 30RA/RH - page 11

    11 4.3 - Menus 4.3.1 - Selecting a menu The MENU button authorises you to select a menu from the 10 main menus that are available. Each time you press this button one of the 10 LEDs lights up in turn alongside each of the icons representing a main menu. The acti ve menu is the one against which the LED is lit. If a menu is empty then its LED is not ...

  • Carrier AQUASNAP 30RA/RH - page 12

    12 0 0 SEtPoint 1 1 6.0 6.0 5.9 5.8 5.7 1 5.7 MODIFYING THE V ALUE OF A P ARAMETER OPERA TION PRESS BUTTON MENU LED ITEM NUMBER ITEM V ALUE 2-DIGIT DISPLA Y 4-DIGIT DISPLA Y Hold on the MENU button until the LED for SETPOINT lights. PRO-DIALOG Junior interface: Press the menu button, until SETPOINTS is displayed in the 4-digit display Press one of ...

  • Carrier AQUASNAP 30RA/RH - page 13

    13 S TATUS TEMPERATURES PRESSURES SETPOINTS INPUTS OUTPUTS CONFIGURATION ALARMS ALARMS HISTORY ALARMS USER [USEr] SERVICE [SErviCE] FACTORY [FACtorY] RUNTIME 1 [RuntiME 1] RUNTIME 2 [RuntiME 2] MAINTENANCE [MAintEnAnCE] PERIOD 3 [PEriod 3] PERIOD 4 [PEriod 4] PERIOD 5 [PEriod 5] PERIOD 6 [PEriod 6] PERIOD 7 [PEriod 7] PERIOD 8 [PEriod 8] PERIOD 1 [ ...

  • Carrier AQUASNAP 30RA/RH - page 14

    14 MENU Menu tree structure Legend * Displayed if the configuration requires it ** Displayed if the alarm exists - Not in use ITEM 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ST A TUS Default display Mode Chiller occupied mode* Minutes left Cooling/heating selection* Cooling/heating status* Unit capacity in % Capacity circuit A in %* Capacity circuit ...

  • Carrier AQUASNAP 30RA/RH - page 15

    15 INFORMA TION MENU (3) ITEM FORMA T UNITS 0 ±nn.n °C LOFF - L-On - L-Sc - CCn - rEM - MASt - OFF - rEADY - dELA Y - StOPPing - running - triPout - OvErridE - dEFrOSt - OCCUPIEd - UNOCCUPIEd - COOL - HEA T - StAndbY - BotH - ALArM - ALErt - MAStEr - SLAvE - 1 [1] nn - 2 [2] - occu unoc Forc 3 nn.n minutes 4 [2] - HEAt - COOL - Auto - 5 [2] HEAt ...

  • Carrier AQUASNAP 30RA/RH - page 16

    16 DESCRIPTION The delay at start-up operates after the unit has been switched on. If the delay has not expired, the mode is active . The dela y is configured in the User Configuration 1 menu. The second cooling/heating setpoint is active. See section 5.6.1 The third heating setpoint is active. See section 5.6.1 In this mode, the unit uses the rese ...

  • Carrier AQUASNAP 30RA/RH - page 17

    17 SETPOINTS MENU [2] ITEM FORMA T UNITS RANGE 0 ±nn.n ° C See table below 1 ±nn.n ° C See table below 2 nnn °C See table below 3 [1] nnn °C See table below 4 [1] nn.n ° C See table below 5 [1] ±nn.n °C 3.8 to 50 6 [1] ±nn.n °C 0 to 46 7 nnn % 0 to 100 8 [1] nnn % 0 to 100 9 [1] nnn % 0 to 100 10 ±nn.n °C/min 0.1 to 1.1 11 [1] ±nn.n ? ...

  • Carrier AQUASNAP 30RA/RH - page 18

    18 INPUTS MENU [2] ITEM FORMA T UNITS 0 oPEn/CLoS - 1 [1] oPEn/CLoS - 2 oPEn/CLoS - 3 oPEn/CLoS - 4 [1] oPEn/CLoS - 5 [1] oPEn/CLoS - 6 [1] oPEn/CLoS - 7 oPEn/CLoS - 8 [1] b 1 b 2 b 3 - 9 [1] b 1 b 2 b 3 - LE A VING WA TER TEMPERA TURE CONTROL SETPOINT - °C R-22/R-407C Minimum cooling value W ater 5.0 Medium brine 0.0 Brine -10.0 Maximum cooling v ...

  • Carrier AQUASNAP 30RA/RH - page 19

    19 4.3.10 - Description of the Outputs/Tests menu 4.3.10.1 - General This menu displays the status of the controller outputs. More- ov er , when the machine is fully stopped (LOFF) the outputs can be activated for manual or automatic tests (the access to the tests is password controlled). 4.3.10.2 - Menu description OUTPUTS ST A TUS & TESTS MEN ...

  • Carrier AQUASNAP 30RA/RH - page 20

    20 OUTPUTS ST A TUS & TESTS MENU [2] [3] continued ITEM FORMA T UNITS 13 [1] b 1 b 2 b 3 b 4 tESt 14 [1] YES - no - tESt % 15 A uto tESt - DESCRIPTION Additional heating stage status. b 1 = stage 1 b 2 = stage 2 b 3 = stage 3 b 4 = stage 4 In test mode the arrow keys successively display 0001, 0010, 0100 and 1000 to force the status of each ele ...

  • Carrier AQUASNAP 30RA/RH - page 21

    21 The table belo w describes the dif ferent sequences of the automatic test. TEST NUMBER 0 1 2 3 4 5, 6 7, 8, 9 10, 11 12, 13, 14 15, 16, 17 18 19, 20, 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 DESCRIPTION Outdoor temperature sensor test Pressure sensor test - circuit A Pressure sensor test - circuit B (dual-circuit units only) Defrost ...

  • Carrier AQUASNAP 30RA/RH - page 22

    22 The table below describes the faults that can be displayed during the automatic test. TEST F AUL T 1 2 3 4 5 6 7 8 9 10 11, 12, 13; 14, 15 16, 17, 18, 19, 20 21 22, 23; 24, 25, 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 DESCRIPTION Outdoor air thermistor outside range Outdoor air value read not validated ...

  • Carrier AQUASNAP 30RA/RH - page 23

    23 SUB-MENU USER CONFIGURA TION * only displayed if configuration requires. NOTE: The items in brackets show what is displayed on the user interface. SCHEDULE 1 [ScHEduLE 1MEnu]* Return to previous menu SUB-MENU: Period 1 [PErIod 1] SUB-MENU: Period 2 [PErIod 2] SUB-MENU: Period 3 [PErIod 3] SUB-MENU: Period 4 [PErIod 4] SUB-MENU: Period 5 [PErIod ...

  • Carrier AQUASNAP 30RA/RH - page 24

    24 4.3.1 1.3 - Description of the User 1 Configuration sub-menu 1 This item shall be masked when not used. 2 Access to menu is read/write. U SER 1 CONFIGURA TION SUB-MENU [2] ITEM FORMA T UNITS DE FA U L T COMMENTS 0 USEr MEnu - - When selected this item authorises return to the previous menu. 2 [1] YES/no - no Ramp loading select . F or units with ...

  • Carrier AQUASNAP 30RA/RH - page 25

    25 4.3.1 1.4 - Description of the User 2 Configuration sub-menu 4.3.1 1.6 - Description of the Time Schedules sub-menus The control provides two timer programs: schedule 1 and schedule 2 that can be activated if the unit is equipped with an optional CCN/clock board (if the CCN/clock board is not installed, the two schedules are permanently in occup ...

  • Carrier AQUASNAP 30RA/RH - page 26

    26 PERIOD X CONFIGURA TION SUB-MENUS (X = 1 TO 8) ITEM # FORMA T COMMENTS 0 Period X Menu Indicates the period (X) you are going to configure. When selected this item authorises a return to the main menu. 1n 1 n 2 n 3 n 4 Occupied period - Start time* . 00:00 to 24:00 Authorises entering the time of day at which the occupied period starts. 2n 1 n 2 ...

  • Carrier AQUASNAP 30RA/RH - page 27

    27 BROADCAST CONFIGURA TION SUB-MENU ITEM # FORMA T COMMENTS 0 broAdCASt MEnu When selected this item authorises a return to the main menu. 1 YES/no Determines whether or not the unit is a broadcast acknowledger when the unit is connected on a CCN network . There must be only one broadcast acknowledger in a CCN. W arning : if the unit operates in s ...

  • Carrier AQUASNAP 30RA/RH - page 28

    28 ITEM # 0 [1] 1 [1] 2 [1] 3 [1] 4 [1] 5 [1] FORMA T X ALArM rESEt ALArM 1 to 55 1 to 55 1 to 55 1 to 55 1 to 55 COMMENTS X alarms are active Reset of alarms is requested T o reset all active alar ms, continuously press the Enter ke y . ‘rESET ALArM’ is then displayed. Press the select key again: all alarms are reset. Current alarm code 1* Cur ...

  • Carrier AQUASNAP 30RA/RH - page 29

    29 5 - PRO-DIALOG CONTROL OPERATION 5.1 - Start/stop control The table below summarises the unit control type and stop or go status with regard to the following parameters. - Operating type : this is selected using the start/stop button on the front of the user interface. - Remote start/stop contacts : these contacts are used when the unit is in re ...

  • Carrier AQUASNAP 30RA/RH - page 30

    30 CHIL_S_S - - - - - - Disable - - - - Disable - - - - - - Enable - - - - Enable REMOTE ST ART/STOP CONT ACT - - - - Off - - - - Off - - - - - On cooling On heating On auto - - On cooling On heating On auto - MASTER CONTROL TYPE - - - - - - - - Local Remote Remote CCN CCN - - - - - - Local Remote Remote Remote CCN ST ART/STOP SCHEDULE MODE - - - U ...

  • Carrier AQUASNAP 30RA/RH - page 31

    31 5.3 - Evaporator water pump control The unit can control one or two e va porator water pumps. The evaporator water pump is turned on when this option is configured (see User configuration) and when the unit is in on e of the on modes described above or in delay mode. Since th e minimum value for the delay at start-up is 1 minute (configurable be ...

  • Carrier AQUASNAP 30RA/RH - page 32

    32 The following table summarises the possible selections depending on the control types (local, remote or CCN) and the following parameters: - Setpoint select in local control : item #12 of the Infor- mation menu permits selection of the active setpoint, if the unit is in local operating type. - Heating/cooling operating mode - Control contacts: s ...

  • Carrier AQUASNAP 30RA/RH - page 33

    33 5.6.2 - Reset Reset means that the active setpoint is modified so that less machine capacity is required (in cooling mode, the setpoint is increased, in heating mode it is decreased). This modif ica tion is in general a reaction to a drop in the load. For the Pro-Dialog control system, the source of the reset can be configured in the User 1 conf ...

  • Carrier AQUASNAP 30RA/RH - page 34

    34 5.11 - Defrost function Defrost is activated, when the unit is in heating mode, in order to reduce frost build-up on the air heat exc hanger . The defrost cycle can only be applied to one circuit at a time. During the defrost cy cle the fans of that circuit are stopped, and the four- way refrigerant valve is reversed, forcing the circuit to cool ...

  • Carrier AQUASNAP 30RA/RH - page 35

    35 A LARM C ODE 1 2 3 5 6 7 9 10 11 12 13 14 15 16 17 18 21 22 23 24 ALARM NAME Compressor A1 failure Compressor A2 failure Compressor A3 failure Compressor B1 failure Compressor B2 failure Compressor B3 failure Heat exchanger leaving fluid thermistor failure Heat exchanger entering fluid thermistor failure CHWS fluid thermistor failure (master/sla ...

  • Carrier AQUASNAP 30RA/RH - page 36

    Order No. 13444-76, 06.2005. Supersedes order No.: 13429-76, 06.2004. Manufactured by: Carrier s.a., Montluel, France. Manufacturer reserves the right to change any product specification without notice. Printed in the Netherlands on chlorine-free paper. A LARM C ODE 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55-2 55- ...

Produzent Carrier Kategorie Air Conditioner

Dokumente, die wir vom Produzenten des Geräts Carrier AQUASNAP 30RA/RH erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Carrier
- Bedienungsanleitungen AQUASNAP 30RA/RH
- Produktkarten Carrier
- Informationsbroschüren
- oder Energieetiketten Carrier AQUASNAP 30RA/RH
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Carrier AQUASNAP 30RA/RH.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Carrier AQUASNAP 30RA/RH, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Carrier AQUASNAP 30RA/RH. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Carrier AQUASNAP 30RA/RH ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Carrier AQUASNAP 30RA/RH, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Carrier AQUASNAP 30RA/RH hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Carrier AQUASNAP 30RA/RH verständlich ist.

Eine gänzliche Bedienungsanleitung von Carrier sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Carrier AQUASNAP 30RA/RH bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Carrier AQUASNAP 30RA/RH befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Carrier AQUASNAP 30RA/RH, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Carrier AQUASNAP 30RA/RH - die uns die ersten Schritte während der Nutzung von Carrier AQUASNAP 30RA/RH erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Carrier AQUASNAP 30RA/RH hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Carrier AQUASNAP 30RA/RH im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Carrier AQUASNAP 30RA/RH?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Carrier AQUASNAP 30RA/RH nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Carrier AQUASNAP 30RA/RH hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)