  • Friedrich UE10 - page 1

    UE08/UE10/UE12 (04/07) 230 Volts UE10:Staring with serial number LGDK00001 UE12:Staring with serial number LGDK00001 Thru-the-Wall Series Thru-the-Wall Series Ser vice and P ar ts Ma nual 115 Volts UE08: Staring with serial number LGCK00001 ...

  • Friedrich UE10 - page 2

    —2— 1. PREF A CE 1.1 SAFETY PRECAUTIONS ...............................2 1.2 INSULATION RESISTANCE TEST.................2 1.3 SPECIFICATIONS ..........................................3 1.4 FEATURES .....................................................4 1.5 CONTROL LOCATIONS .................................4 2. DISASSEMBL Y INSTR UCTIONS 2.1 ME ...

  • Friedrich UE10 - page 3

    —3— 1.3 SPECIFICA TIONS 1.3.1 FOR UE08A13B/UE10A33B/UE12A33B REMARK POWER SUPPLY CAPACITY (Btu/h) INPUT (W) RUNNING CURRENT (A) E.E.R. (Btu/W.h) CAPACITY (Btu/h) INPUT (W) RUNNING CURRENT (A) INDOOR (°C) OUTDOOR (°C) INDOOR (°C) OUTDOOR (°C) REFRIGERANT (R-22) CHARGE(g) EVAPORATOR CONDENSER FAN, INDOOR FAN, OUTDOOR FAN SPEEDS (FAN/COOLING/H ...

  • Friedrich UE10 - page 4

    1.4 FEA TURES • Designed for cooling only. • Powerful and quiet cooling. • Top-down chassis for the simple installation and service. 1.5 CONTR OL LOCA TIONS • Built in adjustable THERMISTOR and THERMOSTAT. • Washable one-touch filter. • Compact size. • VENTILA TION Push the lever to the "CLOSE" position to cool, heat or reci ...

  • Friedrich UE10 - page 5

    —5— 2.1 MECHANICAL P AR TS 2.1.1 FRONT GRILLE 1. Open the inlet grille downward. 2. Remove the screw which fastens the front grille. 3. Pull the front grille from the right side. 4. Remove the front grille. (See Fig. 1) 5. Re-install the component by referring to the removal procedure. 2.1.2 CABINET 1. After disassembling the FRONT GRILLE, remo ...

  • Friedrich UE10 - page 6

    Figure 7 —6— 2.2 AIR HANDLING P AR TS 2.2.1 ORIFICE, HEA TER ASSY AND TURBO F AN 1. Remove the front grille. (Refer to section 2.1.1) 2. Remove the cabinet. (Refer to section 2.1.2) 3. Remove the 2 screws which fasten the evaporator at the left side and the right side. (See Fig. 4) 4. Move the evaporator sideward carefully. 5. Remove the 2 term ...

  • Friedrich UE10 - page 7

    —7— 2.2.3 SHROUD 1. Remove the fan. (Refer to section 2.2.2) 2. Remove the screw which fastens the shroud. 3. Remove the shroud. (See Fig. 9) 4. Re-install the components by referring to the removal procedures, above. 2.3 ELECTRICAL P AR TS 2.3.1 MO T OR 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the clamp cord and disconnect the ...

  • Friedrich UE10 - page 8

    —8— 2.3.4 PO WER CORD 1. Remove the control box. (Refer to section 2.1.3) 2. Unfold the control box. (Refer to section 2.3.3) 3. Disconnect the grounding screw from the control box. 4. Disconnect 2 receptacles. 5. Remove a screw which fastens the clip cord. 6. Pull the power cord. (See Fig. 13) 7. Re-install the components by referring to the r ...

  • Friedrich UE10 - page 9

    —9— 2.4 REFRIGERA TION CYCLE 2.4.1 CONDENSER 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the brace and the shroud cover. (Refer to section 2.2.1) 3. Remove the 5 screws which fasten the condenser. 4. After discharging the refrigerant completely into a Freon TM Recovery System, unbraze the interconnecting tube at the condenser conn ...

  • Friedrich UE10 - page 10

    —10— — Replacement of the refrigeration cycle. 1. When replacing the refrigeration cycle, be sure to discharge the refrigerant system using a Freon TM recovery System. Install a valve for the recovery before venting the Freon. Remove the valve when finished. 2. After discharging the unit completely, remove the desired component, and unbrace t ...

  • Friedrich UE10 - page 11

    —11— Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pinch-off tool capable of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve. A COMPOUND GAUGE EVAPORATOR (LOW PRESSURE SIDE) COMPRESSOR CAPILLARY TUBE CONDENSER (HIGH PRESSURE SIDE) SEE INSETS BELOW MAN ...

  • Friedrich UE10 - page 12

    — 12 — 3. TR OUBLESHOO TING GUIDE 3.1 OUTSIDE DIMENSIONS 19- 21 / 32 " (499mm) 24- 21 / 32 " (626mm) 14- 13 / 32 " (366mm) CONDENSER COILS EV APORA T OR COILS FA N M OTO R : REFRIGERANT FLOW TURBO F AN CAPILLAR Y TUBE COMPRESSOR 3.2 PIPING SYSTEM Following is a brief description of the important components and their functions in ...

  • Friedrich UE10 - page 13

    — 13 — 3.3 TR OUBLESHOO TING GUIDE In general, possible trouble is classified in two causes. The one is called Starting Failure which is caused from an electrical defect, and the other is Ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application. Unit is running but cooling is ineffective Ineffective ...

  • Friedrich UE10 - page 14

    — 14 — Fails to Start Check circuit break er and fuse. Gas leakage at f eeler bulb of ther mostat Check control s witch. Only f an fails to start. Improper wiring. Def ect of fan motor capacitor . Irregular motor resistance ( ). Irregular motor insulation ( ). Replacement of f an motor Regular but f ails to star t Replacement of compressor (loc ...

  • Friedrich UE10 - page 15

    — 15 — — 15 — COMPLAINT CAUSE REMEDY Check voltage at outlet. Correct if none. Check voltage to rotary switch. If none, check power supply cord. Replace cord if circuit is open. Check switch continuity. Refer to wiring diagram for terminal identification. Replace switch if defective. Connect wire. Refer to wiring diagram for terminal identi ...

  • Friedrich UE10 - page 16

    — 16 — NAME PLATE RATING MINIMUM MAXIMUM 115V 103.5V 126.5V 208/230V 187V 253V COMPLAINT CAUSE REMEDY Check voltage. See the limits at the bottom of this page. If not within limits, call an electrician. Check the wire connections, if loose, repair or replace the terminal. If wires are off, refer to wiring diagram for identification, and replace ...

  • Friedrich UE10 - page 17

    — 17 — COMPLAINT CAUSE REMEDY Check the voltage. See the limits on the preced- ing page. If not within limits, call an electrician. Check overload, if externally mounted. Replace if open. (If the compressor temperature is high, remove the overload, cool, and retest.) If not running, determine the cause. Replace if required. Remove the cabinet. ...

  • Friedrich UE10 - page 18

    — 18 — 4. SCHEMA TIC DIA GRAM 4.1 CIRCUIT DIA GRAM • MODEL : UE08A13B/UE10A33B/UE12A33B 6411A20056L 6411A20056Q 2H00598F 4681A20044H 4681A20041C 4681A20041M 0CZZA20012A 6120AR2359E 2H01127D 6750A30001N 6750U-L028A 6750U-L058A 5300A20003B  5300A20003A NO. 1 2 3 4 5 7 8 Q'TY PER SET 1 1 1 1 1 1 1 RE- MARKS DESCRIPTION POWER COR ...

  • Friedrich UE10 - page 19

    — 19 — 5. EXPLODED VIEW • MODEL: UE08A13B/UE10A33B/UE12A33B 753011 W48602 559010 346811 349600 567502 349001 130410 W48602 137215 149410 W0CZZ 264110 130900 135312 147581 147582-2 147582-1 352390 148000 550140 149980 359012 266003 269310 152302 135313 E D F A G C B 749180 435301 ' F T IM E R P O W E R M O D E T E M P F A N S PE E D F 1 L ...

  • Friedrich UE10 - page 20

    — 20 — 6. REPL A CEMENT P A R TS LIST R: Service Parts N: Non Service parts LocNo FRD P/NO DESCRIPTION REMARK W0CZZ 67300725 CA PA CITOR, DRAWING R 266003 67300502 SWITCH, RO TA RY R 269310 67300404 THERM OST A T AS SEM BLY R 130410 67302923 BA SE A SSEMBLY, SINGLE R 130900 67303705 CA BINET R 135313 67306104 G RILLE, INLET R 135312 67306006 GR ...

  • Friedrich UE10 - page 21

    LocNo FRD P/NO DESCRIPTION REMARK 266003 67300502 SWITCH, RO TA RY R 269310 67300404 THERM OST A T AS SEM BLY R 130410 67302919 BA SE A SSEMBLY, SINGLE R 130900 67303705 CA BINET R 135313 67306104 GRILLE, INLET R 135312 67306005 GRILLE A SSEMBLY , FRONT (SINGLE) R 137215 67305504 PA NEL A SSEMBLY, CONT ROL R W48602 67302500 CLA M P, SPRING R 346811 ...

  • Friedrich UE10 - page 22

    LocNo FRD P/NO DESCRIPTION REMARK 130410 67302921 BA SE A SSEMBLY, SINGLE R 130900 67303705 CA BINET R 135312 67306005 GRILLE A SSEMBLY , FRONT (SINGLE) R 135313 67306104 GRILLE, INLET R 137215 67305504 PA NEL A SSEMBLY, CONT ROL R 147581 67306203 LOUVER, HORIZONT A L R 147582-1 67306252 LOUVER, VERTICA L R 147582-2 67306253 LOUVER, VERTICA L R 148 ...

  • Friedrich UE10 - page 23

    UE08/UE10/UE12 (06/07) Printed in China Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 357-4480 FRIEDRICH AIR CONDITIONING CO. Visit our web site at www.friedrich.com P/NO.:3828A20040L ...

Produzent Friedrich Kategorie Air Conditioner

Dokumente, die wir vom Produzenten des Geräts Friedrich UE10 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Friedrich
- Bedienungsanleitungen UE10
- Produktkarten Friedrich
- Informationsbroschüren
- oder Energieetiketten Friedrich UE10
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Friedrich UE10.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Friedrich UE10, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Friedrich UE10. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Friedrich UE10 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Friedrich UE10, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Friedrich UE10 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Friedrich UE10 verständlich ist.

Eine gänzliche Bedienungsanleitung von Friedrich sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Friedrich UE10 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Friedrich UE10 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Friedrich UE10, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Friedrich UE10 - die uns die ersten Schritte während der Nutzung von Friedrich UE10 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Friedrich UE10 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Friedrich UE10 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Friedrich UE10?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Friedrich UE10 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Friedrich UE10 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)