    Sun Microsystems, Inc. www .sun.com Submit comments about this document at: http://www.sun.com/hwdocs/feedback Sun ™ SNMP Management Agent Addendum f or the Netr a ™ 440 Ser v er P ar t No . 817-6832-10 April 2004, Revision A ...

  • Sun Microsystems Netra 440 - page 2

    Copyright 2004 Sun Microsystems, Inc., 4150 Network Cir cle, Santa Clara, California 95054, U.S.A. All rights reserved. Sun Microsystems, Inc. has intellectual pr operty rights relating to technology that is described in this document. In particular , and without limitation, these intellectual property rights may include one or mor e of the U.S. pa ...

  • Sun Microsystems Netra 440 - page 3

    i Contents Sun SNMP Management Agent Addendum for the Netra 440 Server 1 Sun SNMP Management Agent 2 Netra 440 Server SNMP Containment Model 2 Component and Indicator Identification 10 Fans and Fan Trays 14 Fan Failures 14 Detecting Fan Status 17 Power Supplies 17 Power Supply Failures 18 Detecting Power Supply Status 21 Dry Contact Alarm Relays an ...

  • Sun Microsystems Netra 440 - page 4

    ii Sun SNMP Management Agent Addendum for the Netra 440 Server • April 2004 ...

  • Sun Microsystems Netra 440 - page 5

    1 Sun SNMP Management Agent Addendum for the Netra 440 Server This document describes how the Netra™ 440 server fans, power supplies, and LED indicators are r epresented in the Sun™ Simple Network Management Pr otocol (SNMP) Agent for Sun Fire™ and Netra Systems. This document contains the following sections: ■ “Sun SNMP Management Agent? ...

  • Sun Microsystems Netra 440 - page 6

    2 Sun SNMP Management Agent Addendum for the Netra 440 Server • April 2004 Sun SNMP Management Agent The Sun SNMP Management Agent for Sun Fire and Netra Systems pr ovides the management of supported systems using the Simple Network Management Protocol (SNMP). Using the Sun SNMP Management Agent, you can monitor inventory , configuration, and ser ...

  • Sun Microsystems Netra 440 - page 7

    Sun SNMP Management Agent Addendum f or the Netra 440 Server 3 T ABLE 1 Netra 440 Server Containment Model (Hierarchy) Model Description For Location, See: Netra 440 Chassis ➥ Alarm Board Critical Alarm Relay Major Alarm Relay Minor Alarm Relay User Alarm Relay ➥ System Board OpenBoot PROM ➥ Battery Battery V oltage Monitor ➥ CPU/Memory Slo ...

  • Sun Microsystems Netra 440 - page 8

    4 Sun SNMP Management Agent Addendum for the Netra 440 Server • April 2004 ➥ Processor 1 Memory Bank 0 FIGURE 4 – item 3 FIGURE 5 – item 5 ➥ Processor 1 Memory Bank 0 DIMM 0 FIGURE 4 – item 3 FIGURE 5 – item 1 ➥ Processor 1 Memory Bank 0 DIMM 1 FIGURE 4 – item 3 FIGURE 5 – item 2 ➥ Processor 1 Memory Bank 1 FIGURE 4 – item 3 ...

  • Sun Microsystems Netra 440 - page 9

    Sun SNMP Management Agent Addendum f or the Netra 440 Server 5 CPU 2 Ambient T emperature Sensor ➥ CPU/Memory Slot 3 (far right - viewed from front) FIGURE 4 – item 5 ➥ CPU/Memory Module 3 FIGURE 4 – item 5 ➥ Processor 3 Memory Bank 0 FIGURE 4 – item 5 FIGURE 5 – item 5 ➥ Processor 3 Memory Bank 0 DIMM 0 FIGURE 4 – item 5 FIGURE 5 ...

  • Sun Microsystems Netra 440 - page 10

    6 Sun SNMP Management Agent Addendum for the Netra 440 Server • April 2004 +12V Rail Monitor -12V Rail Monitor Ethernet 0 1.2V Analog Rail Monitor Ethernet 0 1.2V Digital Rail Monitor Ethernet 1 1.2V Analog Rail Monitor Ethernet 1 1.2V Digital Rail Monitor SCSI Controller 1.8V Rail Monitor T omatillo/Cassini 2.5V Rail Monitor Motherboard Power OK ...

  • Sun Microsystems Netra 440 - page 11

    Sun SNMP Management Agent Addendum f or the Netra 440 Server 7 ➥ Fan T ray 1 FIGURE 2 – item 14 ➥ Fan 1 FIGURE 2 – item 14 ➥ Fan 1 Active Indicator FIGURE 2 – item 9 Fan 1 Service-Required Indicator FIGURE 2 – item 8 Fan 1 T achometer ➥ Fan T ray 2 FIGURE 2 – item 16 ➥ Fan 2 FIGURE 2 – item 16 ➥ Fan 2 Active Indicator FIGURE ...

  • Sun Microsystems Netra 440 - page 12

    8 Sun SNMP Management Agent Addendum for the Netra 440 Server • April 2004 HDD2 Service Required Indicator † Hard Disk Drive 2 (2nd fr om right - viewed from fr ont) FIGURE 2 – item 15 ➥ Hard Disk Drive 3 Bay (right - viewed fr om front) FIGURE 2 – item 17 ➥ HDD3 Okay T o Remove Indicator FIGURE 2 – item 13 HDD3 Service Required Indic ...

  • Sun Microsystems Netra 440 - page 13

    Sun SNMP Management Agent Addendum f or the Netra 440 Server 9 ➥ PS 2 Okay-T o-Remove Indicator FIGURE 3 – item 20 and item 14 PS 2 Active Indicator FIGURE 3 – item 20 and item 12 PS 2 Service-Required Indicator FIGURE 3 – item 20 and item 13 PS 2 Over-Curr ent Fault Monitor PS 2 Fan Under-Speed Fault Monitor PS 2 Over-V oltage Fault Monito ...

  • Sun Microsystems Netra 440 - page 14

    10 Sun SNMP Management Agent Addendum for the Netra 440 Server • April 2004 Component and Indicator Identif ication The following figur es show the location of the Netra 440 server components. T ABLE 1 lists of how the agent models these components in an SNMP hierarchy . FIGURE 1 Front Panel Indicators and Components SCC 8 9 10 11 1 23 Indicators ...

  • Sun Microsystems Netra 440 - page 15

    Sun SNMP Management Agent Addendum f or the Netra 440 Server 11 FIGURE 2 Hard Disk Drive and Fan T ray Components and Indicators SCC 1 2 3 4 5 6 Components and indicators: 1. Hard disk drive (HDD) 0 2. F an tra y 0 3. HDD 1 4. HDD0 oka y to remov e 5. F an tra y 0 ser vice required 6. F an tra y 0 activ e 10. HDD2 oka y to remov e 11. F an tra y 2 ...

  • Sun Microsystems Netra 440 - page 16

    12 Sun SNMP Management Agent Addendum for the Netra 440 Server • April 2004 FIGURE 3 Rear Panel Components and Indicators 1 23 4 5 6 7 8 91 0 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Components and indicators: 1. System locator 2. System ser vice-required 3. System active 4. Network management por t 5. Serial management por t 6. PCI card slot ...

  • Sun Microsystems Netra 440 - page 17

    Sun SNMP Management Agent Addendum f or the Netra 440 Server 13 FIGURE 4 Internal Components FIGURE 5 Memory Banks and DIMMs Inter nal components: 1. F an T ra y 3/F an 3 2. CPU/memor y module 0 3. CPU/memor y module 1 4. CPU/memor y module 2 1 2 3 4 5 6 5. CPU/memor y module 3 6. SCSI disk backplane 4 12 3 Memor y banks and DIMMs 1. Memor y bank 0 ...

  • Sun Microsystems Netra 440 - page 18

    14 Sun SNMP Management Agent Addendum for the Netra 440 Server • April 2004 Fans and Fan T rays The Netra 440 server fans in the fan trays are identif ied in the ENTITY - MIB::entPhysicalT able by the entPhysicalDescr of Fan number , where number is a number in the range from 0 to 3. The fans ar e repr esented in the following tables that extend ...

  • Sun Microsystems Netra 440 - page 19

    Sun SNMP Management Agent Addendum f or the Netra 440 Server 15 ■ The sunPlatAlarmState values for the status LEDs will change and sunPlatAttributeChangeInteger traps will be generated with the form shown in T ABLE 5 . If the fan recovers fr om the failure, the following changes will occur: ■ The sunPlatEquipmentOperationalState value for the f ...

  • Sun Microsystems Netra 440 - page 20

    16 Sun SNMP Management Agent Addendum for the Netra 440 Server • April 2004 sunPlatNotif icationAdditionalT ext entPhysicalName of the fan tachometer : Tachometer threshold crossed sunPlatNotif icationPerceivedSeverity warning(5) or cleared(6) sunPlatNotif icationProbableCause coolingFanFailure(107) sunPlatNotif icationSpecificPr oblem coolingFan ...

  • Sun Microsystems Netra 440 - page 21

    Sun SNMP Management Agent Addendum f or the Netra 440 Server 17 Detecting Fan Status Y ou can detect fan status using the following mechanisms: ■ Polling sunPlatNumericSensorCurrent and sunPlatNumericSensorLowerThresholdNonCritical for the fan's tachometer and comparing their values. ■ Polling the sunPlatEquipmentOperationalState of the fa ...

  • Sun Microsystems Netra 440 - page 22

    18 Sun SNMP Management Agent Addendum for the Netra 440 Server • April 2004 Power Supply Failur es If any of the power supply sensors detect a fault the following changes will occur: ■ The sunPlatBinarySensorCurrent value for the sensor that detected the fault will change from true(1) to false(2) and a sunPlatAttributeChangeInteger trap will be ...

  • Sun Microsystems Netra 440 - page 23

    Sun SNMP Management Agent Addendum f or the Netra 440 Server 19 T ABLE 6 sunPlatAttributeChangeInteger T rap for a Power Supply Sensor V ariable V alue sunPlatNotif icationEventId unique numeric identif ier sunPlatNotif icationT ime date time sunPlatNotif icationObject entPhysicalDescr . ps sensor instance * * ps sensor instance indicates the row i ...

  • Sun Microsystems Netra 440 - page 24

    20 Sun SNMP Management Agent Addendum for the Netra 440 Server • April 2004 sunPlatNotif icationAdditionalT ext entPhysicalName of the sensor : Voltage threshold crossed sunPlatNotif icationPerceivedSeverity major(3) or cleared(6) sunPlatNotif icationProbableCause powerProblem(58) sunPlatNotif icationSpecificPr oblem powerProblem sunPlatNotif ica ...

  • Sun Microsystems Netra 440 - page 25

    Sun SNMP Management Agent Addendum f or the Netra 440 Server 21 Detecting Power Supply Status Y ou can use the following mechanisms to detect power supply status: ■ Poll the value of sunPlatBinarySensorCurrent for each of the power supply sensors. ■ Poll the value of sunPlatEquipmentOperationalState for the power supply . ■ Receiving a sunPla ...

  • Sun Microsystems Netra 440 - page 26

    22 Sun SNMP Management Agent Addendum for the Netra 440 Server • April 2004 Alarm State Changes The alarm relay state cannot be changed using SNMP set commands. However , the alarm relay state can be changed using the Sun Advanced Lights Out Manager (ALOM) setalarm command. For more information about ALOM commands, refer to the Sun Advanced Light ...

Produzent Sun Microsystems Kategorie Server

Dokumente, die wir vom Produzenten des Geräts Sun Microsystems Netra 440 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Sun Microsystems
- Bedienungsanleitungen Netra 440
- Produktkarten Sun Microsystems
- Informationsbroschüren
- oder Energieetiketten Sun Microsystems Netra 440
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Sun Microsystems Netra 440.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Sun Microsystems Netra 440, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Sun Microsystems Netra 440. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Sun Microsystems Netra 440 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Sun Microsystems Netra 440, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Sun Microsystems Netra 440 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Sun Microsystems Netra 440 verständlich ist.

Eine gänzliche Bedienungsanleitung von Sun Microsystems sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Sun Microsystems Netra 440 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Sun Microsystems Netra 440 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Sun Microsystems Netra 440, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Sun Microsystems Netra 440 - die uns die ersten Schritte während der Nutzung von Sun Microsystems Netra 440 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Sun Microsystems Netra 440 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Sun Microsystems Netra 440 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Sun Microsystems Netra 440?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Sun Microsystems Netra 440 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Sun Microsystems Netra 440 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)