    SERVICE MANUAL GPIB DC Po wer Sup plie s Agilent Series 668xA For instruments with Seria l Numbers: Agilent M odel 6680 A : US36480 101 and A bove * Agilent M odel 6681 A : US36400 101 and A bove * Agilent M odel 6682 A : US36440 101 and A bove * Agilent M odel 6683 A : US36420 101 and A bove * Agilent M odel 6684 A : US36410 101 and A bove * * Thi ...

  • Agilent Technologies 6682A - page 2

    2 CERTIFICATION Agilent Technologies certifies that this product met its published specifications at time of shipment from the factory. Agilent Technologies further cer tifies that its calibration measur ements are traceable to the United States National Bureau of Standards, to the extent allowed by the B ureau's calibration facility, an d to ...

  • Agilent Technologies 6682A - page 3

    3 SAFETY CONSIDERATIONS GENERAL. This is a Safety Class 1 instrument (provided with terminal for connection to pr otective earth ground). OPER A T ION. B EFORE APPLYING POWER verify that the pro duct is set to match the available line voltage, the correct line fuse is installed, and all sa fety precautions (see follo wing warnings) are taken. In ad ...

  • Agilent Technologies 6682A - page 4

    4 Safety Sy mbol Definitions Symbol Description Symbol Description Direct current Terminal for L ine conductor on perm a nently installed equip m ent Alternating current Caution, risk of electric shock Both direct and alternating cu rrent Cauti on, hot s urfac e Three-phase altern ating current Caution (ref er to accompanying documents) Earth (grou ...

  • Agilent Technologies 6682A - page 5

    5 Table of Contents Introduction ............................................................................................................................................................................ 7 Scope......................................................................................................................................... ...

  • Agilent Technologies 6682A - page 6

    6 Post-Repair Ca libration ........................................................................................................ ............................................. 62 When R equired .................................................................................................................. ....................................... ...

  • Agilent Technologies 6682A - page 7

    Introduction 7 1 Introduction Scope Organization This manu al contains information for troublesh ooting and repairing t o the componen t level Agil ent Series 668x A, 5-kilowatt power supplies. The remainin g ch apters of this manual are organized as follo ws: Chapter Description Chapter 2 Verification procedures to determ i n e the performance lev ...

  • Agilent Technologies 6682A - page 8

    Introduction 8 Related Docume nts Change Sh eet There may or may not be a Manual Cha nge sheet in cluded with this manual (see Manual Revision s). If one is in cluded, be sure to examine it for changes to this manual. Operating Manual Each power supply is shipped with an operating manual (s ee Replaceable Parts, Chapter 5 f or part numbers ) that c ...

  • Agilent Technologies 6682A - page 9

    Introduction 9 Safety Considerations This po w er supp ly is a Safety Class I instrument, which means it has a p rotective earth terminal. This terminal must be connected to earth ground th rough a power s ource equipped w i th a 4- w ir e, groun d receptacle. Ref er to the "Safety Summary" page at the beginn ing of this m a nual f or gen ...

  • Agilent Technologies 6682A - page 10

    Verificatio n 11 2 V erification Introduction This chapte r provides te st procedures for check ing the operati on of Agi lent Series 668xA power s upplies . The required tes t equipment is s pecified and sam ple performance test record sh eets are included. Instru ctions are given for perf orming the tests either from the front panel or from a con ...

  • Agilent Technologies 6682A - page 11

    12 Verif ication Table 2- 1. Test Equip ment Requir ed Ty pe Required Character istics Recommended Model Digital Volt m eter 1 Resolution : 10 nV @ 1V Agilent 3458A Readout : 8 1/2 dig its Accuracy : 20 pp m Current Monitor Resistor 1 Agilen t 6682A, 6683A , Agilent 6684A : Guil dline 9230/30 0 0.001 Ω ± 0.0 4%, 300A , 100W Agil ent 6680A , 6681 ...

  • Agilent Technologies 6682A - page 12

    Verificatio n 13 Programming The Tests General Considerations Procedures are gi ven for programm ing these tests either from th e front panel key pad or from a GPIB controller. The procedures as sume y ou know how to use th e front pane l keypad or how to program over the G PIB (see the Pow er Supply Operating Manual for more information). When usi ...

  • Agilent Technologies 6682A - page 13

    14 Verif ication Operation Verification Tests Table 2-3 lists the requirements for op eration verif ication, which is a subset of the perfor m a nce tests. Table 2- 3. Operation V erification Tests Test Refer T o 1 Tur n-On Chec kout Po w er S uppl y Oper ating M anual 2 Voltage Programmi ng and Readback Accu rac y Table 2-4 3 Current Prog ramming ...

  • Agilent Technologies 6682A - page 14

    Verificatio n 15 Figure 2-1. Constant Voltage (C V) Test Setu p ...

  • Agilent Technologies 6682A - page 15

    16 Verif ication Table 2- 4. Constant Voltage (CV) Tests Acti on Normal Result Voltage Program min g and Readb ack Accuracy This tes t verif ies that th e voltage prog ramming, G PIB readback (GPI B system power suppl ies only ), and fron t panel display functions are within s pecifications. With system power su pplies, values read back over th e G ...

  • Agilent Technologies 6682A - page 16

    Verificatio n 17 Table 2- 4. Constant Voltage (CV) Tests (con tinued) Acti on Normal Result CV Source Effect (cont) 2 Set the transformer to the nominal ac line voltage. Con nect the DVM across +S and -S (see Fig. 2- 1). 3 Turn on t he powe r supply and program t he curren t to its maximum programmable value and the voltage to its full-scale val ue ...

  • Agilent Technologies 6682A - page 17

    18 Verif ication Table 2- 4. Constant Voltage (CV) Tests (con tinued) Acti on Normal Result Transient Recovery Tim e This test measures the time required for the output voltag e to return to w ithin 100mV of its final value follo w ing a 50% change in ou tput load current. Meas urements are made on both the unloading transient (from full load to 1/ ...

  • Agilent Technologies 6682A - page 18

    Verificatio n 19 Constant Current (CC) Tests Test Set up Connect the appropriate cu rrent monitoring resist or (see Table 2-l) as sh own in Fig. 2-3. The accuracy o f the resistor mus t be as specified in the table. Test Pro cedures The test procedures are g iven in Table 2-5. The tests are in dependent and m ay be performed in any order. The C C t ...

  • Agilent Technologies 6682A - page 19

    20 Verif ication Table 2-5. Constant Current (CC) Tests (continue d) Action Normal Result CC Noise (PARD) (cont) 2 Measure the residu al noise on the DVM with the pow er supply tu rned off. Noise generated by other equipment may affect this measurement and should be rem o v ed or factored ou t. 3 Turn on th e po w er supply and program t h e curren ...

  • Agilent Technologies 6682A - page 20

    Verificatio n 21 Table 2-5. Constant Current (CC) Tests (continue d) Action Normal Result CC Source Effect This test measures the change in outpu t cu rrent resulting from a change in ac line voltage from its minimum to its maximum value within the line v oltage specifications. It is recommended th at you use averaged readings f or Steps 6 and 8 of ...

  • Agilent Technologies 6682A - page 21

    22 Verif ication Figure 2-3. CC Load Eff ect Test Set up ...

  • Agilent Technologies 6682A - page 22

    Verificatio n 23 Figure 2-4. CC rms Noise T est Setup ...

  • Agilent Technologies 6682A - page 23

    24 Verif ication Av eraging the CC Measurement s The CC Load Eff ect and CC Source Effect tests m easure the dc regulation of the power supply's ou tput current. When doing these tests, you mu st be sure that the readings taken are truly dc regulatio n v alues and not insta ntaneous ac peaks of the output cu rrent ripple. You can do this by ma ...

  • Agilent Technologies 6682A - page 24

    Verificatio n 25 Table 2- 6. Performan ce Test Record Form Test Facility : __________________________________________ Report No.__ _________ ____________ _________ __________ __________________________________________ Date_____ ______ ______ _________ _______________ _____ __________________________________________ Cust omer__________ _____________ ...

  • Agilent Technologies 6682A - page 25

    26 Verif ication Table 2- 7. Performan ce Test Record for A gilent M odel 6680 A MODEL Agilen t ___________ __ Report No._ ____________ _ Date_____ ___________ _____ Test Descrip tion Mi nim um Spec. Results * Maximu m Spec. Measu rement Uncertaint y Constant Vo ltage Tests Voltage Program min g and Readback Low Voltage (0V) V out Front Panel Displ ...

  • Agilent Technologies 6682A - page 26

    Verificatio n 27 Table 2- 7. Performan ce Test Record for A gilent M odel 6681 A MODEL Agilen t___________ __ Report No._ ____________ _ Date_____ ___________ _____ Test Descrip tion Mi nim um Spec. Results * Maximu m Spec. Measu rement Uncertaint y Constant Vo ltage Tests Voltage Program min g and Readback Low Voltage (0V) V out Front Panel Displa ...

  • Agilent Technologies 6682A - page 27

    28 Verif ication Table 2- 7. Performan ce Test Record for A gilent M odel 6682 A MODEL Agilen t___________ __ Report No._ ____________ _ Date_____ ___________ _____ Test Descrip tion Mi nim um Spec. Results * Maximu m Spec. Measu rement Uncertaint y Constant Vo ltage Tests Voltage Program min g and Readback Low Voltage (0V) V out Front Panel Displa ...

  • Agilent Technologies 6682A - page 28

    Verificatio n 29 Table 2- 7. Performan ce Test Record for A gilent M odel 6683 A MODEL Agilen t___________ __ Report No._ ____________ _ Date_____ ___________ _____ Test Descrip tion Mi nim um Spec. Results * Maximu m Spec. Measu rement Uncertaint y Constant Vo ltage Tests Voltage Program min g and Readback Low Voltage (0V) V out Front Panel Displa ...

  • Agilent Technologies 6682A - page 29

    30 Verif ication Table 2- 7. Performan ce Test Record for A gilent M odel 6684 A MODEL Agilen t___________ __ Report No._ ____________ _ Date_____ ___________ _____ Test Descrip tion Mi nim um Spec. Results * Maximu m Spec. Measu rement Uncertaint y Constant Vo ltage Tests Voltage Program min g and Readback Low Voltage (0V) V out Front Panel Displa ...

  • Agilent Technologies 6682A - page 30

    Troubleshooting 31 3 T rouble shooting Shock Hazard : Mos t of th e procedures in this chapte r must be perf ormed wi th power appli ed and protective covers removed. These procedu res sh ould be done on ly by trained s ervice personn el aware of the hazard f rom electrical shock. This ins trument us es components th at can be damag ed or suffer s ...

  • Agilent Technologies 6682A - page 31

    32 Troubleshooting Test Equipment Required Table 3- 1. Test Equip ment Requir ed Equipment Purpose Recommended Model Logic Probe To check s tates of data l ines. Agil ent 545A Test Clips To gain access to IC pin s. AP Products No. LTC Ammete r/Curren t Shunt To me asure out put current. Agil ent 6680A & 6681A: Burst er 1280 Agil ent 6682A , 668 ...

  • Agilent Technologies 6682A - page 32

    Troubleshooting 33 Table 3- 2. Selftest Error Code s/Messages Code and/or Messag e Descriptio n Probabl e Cause Selftest Error Codes/M essages El FP RAM Front panel RAM test failed (po w er-o n). Microprocesso r A lU3 E2 FP ROM Front panel ROM test failed (po w er-on and * TST?). ROM AlU4 or addres s latch es AlU8 E3 EE CHKSM Front panel EEPRO M ch ...

  • Agilent Technologies 6682A - page 33

    34 Troubleshooting Troubleshooting Charts Figure 3-1 gives overall troubleshooting pr ocedures to isolate the fault to a circuit board or particular circuit (see Figure 3-20 for th e location of th e circuit boards). These procedures include th e use of power- on selftest (Table 3-2) an d sign ature analysi s techniqu es (Table 3-5 t hrough Table 3 ...

  • Agilent Technologies 6682A - page 34

    Troubleshooting 35 Figure 3-1. Overall Troubleshooting (Sheet 1 of 4) ...

  • Agilent Technologies 6682A - page 35

    36 Troubleshooting Figure 3-1. Overall Troubleshooting (Sheet 2 of 4) ...

  • Agilent Technologies 6682A - page 36

    Troubleshooting 37 Figure 3-1. Overall Troubleshooting (Sheet 3 of 4) ...

  • Agilent Technologies 6682A - page 37

    38 Troubleshooting Figure 3-1. Overall Troubleshooting (Sheet 4 of 4) ...

  • Agilent Technologies 6682A - page 38

    Troubleshooting 39 Figure 3-2. No Display Troubleshooting ...

  • Agilent Technologies 6682A - page 39

    40 Troubleshooting Figure 3-3. OV Will Not Fire Troubleshooting ...

  • Agilent Technologies 6682A - page 40

    Troubleshooting 41 Figure 3-4. OV At Turn-On Troubleshooting ...

  • Agilent Technologies 6682A - page 41

    42 Troubleshooting Figure 3-5. Output Held Low Troubleshooting (Shee t 1 of 2) ...

  • Agilent Technologies 6682A - page 42

    Troubleshooting 43 Figure 3-5. Output Held Low Troubleshooting (Shee t 2 of 2) ...

  • Agilent Technologies 6682A - page 43

    44 Troubleshooting Figure 3-6. Output Held High Troubleshooting ...

  • Agilent Technologies 6682A - page 44

    Troubleshooting 45 Figure 3-7. DAC Circuits Troubleshooting ...

  • Agilent Technologies 6682A - page 45

    46 Troubleshooting Figure 3-8. DAC Test Wav eforms ...

  • Agilent Technologies 6682A - page 46

    Troubleshooting 47 Figure 3-9. CV/CC DAC and Amplifier Circuit Troubleshooting ...

  • Agilent Technologies 6682A - page 47

    48 Troubleshooting Figure 3-10. Serial Down Troubleshooting (Sheet 1 of 2) ...

  • Agilent Technologies 6682A - page 48

    Troubleshooting 49 Figure 3-10. Serial Down Troubleshooting (Sheet 2 of 2) ...

  • Agilent Technologies 6682A - page 49

    50 Troubleshooting Figure 3-11. Secondary Interface Down (Sheet 1 of 2) ...

  • Agilent Technologies 6682A - page 50

    Troubleshooting 51 Figure 3-11. Secondary Interface Down (Sheet 2 of 2) ...

  • Agilent Technologies 6682A - page 51

    52 Troubleshooting Figure 3-12. Slow Downprogramming Troubleshooting ...

  • Agilent Technologies 6682A - page 52

    Troubleshooting 53 CV/CC Status Annunciators Troubleshooting When troubleshooting t he C V/CC status annunciators or status readback circu its, firs t measure the voltage drop across th e gating diodes, wh ich are Al0D651 f or the C C circuit and A l0D652 for the CV circu it (see A10, Sheet 2). A con ducting diode indicates an activ e (ON) control ...

  • Agilent Technologies 6682A - page 53

    54 Troubleshooting Table 3-4. FET Troubleshooting Chart (continue d) Procedure Res ult Dyna m ic Trouble shooting 1. Turn off the power supply and rem ove the A3 FET Board with its heat sink assembl y. See "Disassembly Procedures" 2. Short t he collect ors of Q 251 and Q253 or Q 351 and Q3 53 by con necting t he collector (case) of each t ...

  • Agilent Technologies 6682A - page 54

    Troubleshooting 55 Figure 3-13. A3 FET Board Test Waveforms ...

  • Agilent Technologies 6682A - page 55

    56 Troubleshooting Signature A nal y sis Introduction The easiest and most eff icient method of troubl eshooti ng microprocess or-based i nstrument s is with signature an alysis (SA ). This technique is si milar to signal tracing with an oscilloscope in linear circuits. Part of the micropro cessor m emory is dedicated to SA, and a k nown bit stream ...

  • Agilent Technologies 6682A - page 56

    Troubleshooting 57 Test Header s The power su pply has two tes t headers as shown in Figure 3-15, each w ith a jumper that can be moved to diff erent positions for SA testing and for other functions. To gain access to the headers, re m ove t he pow er supply top cover. Pins Description Primary I nterface Tes t Connector A2J106 (Sys tems Suppli es O ...

  • Agilent Technologies 6682A - page 57

    58 Troubleshooting Table 3- 5. Primar y Interface S A Test Description : These signatures ch eck some primary interface circu its on the Systems Supply A2 GPIB Board. Valid A2U106 R OM Firm ware Revision: A .01.06 Test Setup: See Figure 3-17. 1. Turn of f the pow er supply and rem ove the top cov er. 2. Connect SA jum per of conn ector J106 on A2 G ...

  • Agilent Technologies 6682A - page 58

    Troubleshooting 59 Figure 3-1 6. Signature Analysis Connections, (Sheet 1 of 2) ...

  • Agilent Technologies 6682A - page 59

    60 Troubleshooting Figure 3-1 6. Signature Analysis Connections, (Sheet 2 of 2) Table 3-6. Front Panel SA Test Description : These signatures ch eck front panel microprocessor A lU3. Valid A1U4 ROM Fir m w are Revision: A.01.07 Test Setup: See Figure 3-17. 1 .Turn off t he pow er supply and rem o ve th e top cover. 2. To gain access to A 1 Front Pa ...

  • Agilent Technologies 6682A - page 60

    Troubleshooting 61 Table 3-7. Secondary Interface SA Test Description : These signatu res check the secon dary microprocessor A 5U504. Valid A5U504 R OM Firm ware Revision: A .01.04 Test Setup: See Figure 3-17. 1. Turn of f the pow er supply and rem ove the top cov er. 2. To obtain a setup th at allows access to components and tes t points on the A ...

  • Agilent Technologies 6682A - page 61

    62 Troubleshooting Post-Repair Ca libration When Required Calibration is requ ired annually and also when ever certain components are replaced. If com ponents in any of the circuits listed below are replaced, th e supply must be recalibrated. Note For calibration procedures, s ee Appendix A of the Operating Manu al. Location Comp onent A10 Control ...

  • Agilent Technologies 6682A - page 62

    Troubleshooting 63 EEPROM Initia lization EEPROM A lU6 on the A1 F ront Pan el Board stores the su ppl y' s GPIB address, m odel number, an d constants requ ired to program and calibrate the power su pply. If either th e front panel board or th e EEPROM is replaced, the pow er supply must be reinitialized with the proper co ns tants by running ...

  • Agilent Technologies 6682A - page 63

    64 Troubleshooting 10 ! Program to initiali ze EPROM or mov e factory pres et data in 668xA 20 ! power su pplies . 30 ! RE-S TORE " INIT_66 8X" 40 ! Rev A .00.00 dated 09 N ov 1993 50 ! 60 DIM Init_data(1:49),M odel$[5],I dn$[21],C al_data$[40] 70 INT EGER Addr(1:49),Len gth(1: 49) 80 ASSIGN @Ps TO 705 ! Supply mus t be at address 705 90 ...

  • Agilent Technologies 6682A - page 64

    Troubleshooting 65 510 DATA 115,30,20,1,127,. 002701,.2,.000 42,10.25 520 ! 530 Eprom _data_6684: ! ! EEPRO M data for 6684A 540 DATA 93,74,41,0,83, 0,29,70, 131,0 550 DATA 98,21,4.6,10,5 0,0,83, 255,20, 10 560 DATA 6684,87,97,2 8,93,128,5, 255,0,0 570 DATA 1296,6684,0,20,1 80,20,180,1 75,33,98 580 DATA 115,30,20,1,127,. 002701,.2,.000333 ,10.23437 ...

  • Agilent Technologies 6682A - page 65

    66 Troubleshooting 1020 GOSUB Ps_error ! Error if passcode i s not "0"! 1030 IF Err THEN 1040 OUTPUT @Ps ;"*IDN ?" ! Get data f rom model # l ocation 1050 ENTER @Ps ;Idn$ 1060 Model=VA L(Idn$[POS (Idn$,”,”)+1] ) 1070 ELSE 1080 GOTO Start 1090 END IF 1100 ! 1110 OUTPUT @Ps; "CAL:S TATE ON,";Model ! Turn on cal mode, ...

  • Agilent Technologies 6682A - page 66

    Troubleshooting 67 1530 CLEAR SCREEN 1540 PRINT "This program should ONLY be com pleted if your pow er supply ” 1550 PRINT "EEPROM has been replaced or a com ponent that will effect" 1560 PRINT "the cal ibration AND t he alignment of voltag e, overvolt age" 1570 PRINT "and cu rrent is complete A ND unit has passed th ...

  • Agilent Technologies 6682A - page 67

    68 Troubleshooting 2010 IF Err THEN 2020 PRINT "A n error occurred du ring the EEPRO M read/wri te, Check for" 2030 PRINT "program ming errors. In itialization data may be in correct." 2040 STOP 2050 END IF 2060 ! 2070 PRINT "Operat ion com plete. Program stopped." 2080 STOP 2090 ! 2100 Ps_er ror: ! Error ha ndli ng su ...

  • Agilent Technologies 6682A - page 68

    Troubleshooting 69 Top Cover 1. Remove the fou r screws that secure the carry ing straps (tw o TORX 20 screws on each side). These s ame screw s secure the cover to the chas sis. 2. Spread the bottom rear of the cover, and then pull the cov er backwards towards the rear of th e power supply to disengage it from the front panel. Shock Hazard: Hazard ...

  • Agilent Technologies 6682A - page 69

    70 Troubleshooting A 4 AC Input Assembly To remove the A4 AC Input Board first remov e the GPIB board then disconn ect these cables from the following connectors at the GPIB board: 1. Disconn ect the cables going to connector J417 and J420. 2. Disconn ect the cable g oing to conn ector J419. 3. Remove t he three (3) f use ass emblies insi de rear o ...

  • Agilent Technologies 6682A - page 70

    Troubleshooting 71 A 10 Control A ssembly Disconnect the cables from the following connectors at the A10 DC RAIL board: 1. Disconn ect the ribbon cable goin g from t o the A6 Bias board. This cabl e connects t o J509 on th e A10 board bu t it is easier to disconn ect it at the A6 Bias Board. 2. Disconn ect cables from connector J50 7 (phone) and co ...

  • Agilent Technologies 6682A - page 71

    72 Troubleshooting A 1DSP 1 LCD Display 1. Remove t he A1 Front Pan el Board as des cribed i n that procedure. 2. Remove t he nuts s ecuring the LC D display to th e fron t panel ass embly and rem ove the LCD and at tached ribbon cabl e (see CAUTION below ). (When reinstalling this cable, be su re to line up the cable stripe ov er the LCD conn ecto ...

  • Agilent Technologies 6682A - page 72

    Troubleshooting 73 Figure 3-18. Component Locations (Top Cover and RFI Shield Removed) ...

  • Agilent Technologies 6682A - page 73

    74 Troubleshooting Figure 3-1 9. 5-Inch Front Panel Frame A ssemb ly ...

  • Agilent Technologies 6682A - page 74

    Troubleshooting 75 Figure 3-20. 3-Inch Front Panel Frame Assembly ...

  • Agilent Technologies 6682A - page 75

    76 Troubleshooting Figure 3-21. Assembly A10, Exploded View ...

  • Agilent Technologies 6682A - page 76

    Troubleshooting 77 Figure 3-2 2. Assembly A10, Exploded View (668 0A, 6681 A ) ...

  • Agilent Technologies 6682A - page 77

    78 Troubleshooting Figure 3-2 3. Assembly A10, Exploded View (668 2A, 6683 A , 6684 A ) ...

  • Agilent Technologies 6682A - page 78

    Troubleshooting 79 Figure 3-2 4. Three-Ph ase Line Ch oke Subch assis Wirin g ...

  • Agilent Technologies 6682A - page 79

    80 Troubleshooting Figure 3-25. 24 Volt Fan Transformer ...

  • Agilent Technologies 6682A - page 80

    Principles O f Operation 81 4 Principles Of Operatio n Introduction Figure 4- 3 (at th e end of t his chapter) is a block diag ra m sh owing the m aj or circu its wi thin the pow er supply . The pow er supply consists of the following circuits: • A1 Front Panel Board ckts. • A2 G PIB ckt s. • A10 Con trol Board including the secon dary interf ...

  • Agilent Technologies 6682A - page 81

    82 Prin ciples Of Op eration A digital cont rol interface on the A2 GPIB Board prov ides the following power supply fun ctions: • Relay lin k. • Digital 1/0. • Remote inhibit (INH). • Discrete fault indicator (FL T). An optical isolator IC (U113) isolates the FL T output si gnal common f rom the external fault circuit comm o n. The desired ...

  • Agilent Technologies 6682A - page 82

    Principles O f Operation 83 The Secondary Microproces sor translates serial data receiv ed from the A2 board into parallel 12 bit data. The data bus is connected directly to the four DAC/OpAmp circuits. Under con trol of the lip the s elected DAC converts the bus data into an analog s ignal. The DAC ref erence circuit (U503, U504) pr ovides a +10V ...

  • Agilent Technologies 6682A - page 83

    84 Prin ciples Of Op eration any value of load impedance. Sw itching between CV and CC is don e automatically by the CV/CC control circuits at a value of load im pedance equal to th e ratio of the programm ed voltage value to the prog ramm ed current value. A low- l evel CV or CC s ignal is generated by the applicable status com parator (P/O U502) ...

  • Agilent Technologies 6682A - page 84

    Principles O f Operation 85 A 4 A C Input Board The A4 Inpu t Board contains t he Inrush- Current Limi t relay (K 401), Main Pow er Relay (K402), current-li miting resi stors (R407, R408 ) and open- fu se-det ect resistor circui t (R400- R405). On pow er-on, the current-l imit relay (K401) closes allowing the dc rail capacitors to charge under a co ...

  • Agilent Technologies 6682A - page 85

    86 Prin ciples Of Op eration Figure 4-2. 1ST Stage of the FET H-Bridge Configuration Output Circuits The output circuits include the following circuits: • Chassi s m oun ted compo nents. • Two pow er transf or me rs, T900/T901 . • Two in d uctors , L900/ L901. • Four recti fiers , D900 throug h D903. • Output capacitors. • A7 Snu bber b ...

  • Agilent Technologies 6682A - page 86

    Principles Of Operatio n 87 Figure 4-3. Agilent Series 668xA Power Supply, Block Diagram ...

  • Agilent Technologies 6682A - page 87

    Replaceable Parts 89 5 Replace able Part s INTRODUCTION Chapter Organization This section lists the replaceable electrical an d mechanical parts for th e Agilent 668xA series power s upplies. (Component location diagrams are located in Chapter 6.) The lists con sist of tables organized by assemblies as follows: Assembly See Main cha ssis * Tab le 5 ...

  • Agilent Technologies 6682A - page 88

    90 Replac eable Parts How to Order Parts You can order parts from you r local Agilent Technol ogies, In c. Sales and Support Office (see t he list of offices in th e back of this manual). When ordering a part, pleas e include the following information: • the Ag ilent part num ber • the part descripti on • the desi red quanti ty • th e m ode ...

  • Agilent Technologies 6682A - page 89

    Replaceable Parts 91 Table 5- 3. Main Chassi s, Replaceable Parts Ref. Desig. Agilent Part No. Description C907 6680A 0180-4 516 CAP 3300 0uF 7.5V 6681A 0180-4 532 CAP 2200 0uF 16V 6682A 0180-4 615 CAP 1800 0uF 28V 6683A 0180-4 596 CAP 1300 0uF 45V 6684A 0180-4 597 CAP 7.20 0uF 55V C920, 921,9 22,923, 924,925 6682A, 668 3A, 6684A 0160-418 3 CAP 100 ...

  • Agilent Technologies 6682A - page 90

    92 Replac eable Parts Table 5- 3. Main Chassi s, Replaceable Parts (con tinued) Ref. Desig. A gilent P art No. Description 2110-091 0 FUSE (s ee 5060-3513 ) 2110-091 1 FUSE (s ee 5060-3512 ) 3160-0 419 FAN FING ER GUARD 3160-0 571 FA N- TUBEAXIAL 5001-053 8 TRIM-SID ES 5001-053 9 TRIM SIDES,FREN CH GRAY 5001-6 776 CHASSIS , BASE 5001-6 778 PANEL , ...

  • Agilent Technologies 6682A - page 91

    Replaceable Parts 93 Table 5- 3. Main Chassi s, Replaceable Parts (con tinued) Ref. Desig. A gilent P art No. Description 1400-06 11 CABL E CLAM P (GPIB/F AN ) 5080-2 299 LABEL REAR PAN EL 5080-241 3 CRATE ( shi pping con tainer ) 5080-241 4 SKID ( shi pping con tainer ) 5080-241 5 FOAM PA D ( shipping con tainer ) 5080-231 4 EDGE PROTECTOR 12 inch ...

  • Agilent Technologies 6682A - page 92

    94 Replac eable Parts Table 5- 4. A1 Front P anel Board, Rep laceable Part s (continued ) Ref. Desig. A gilent P art No. Description S1 3101-308 8 Line sw itch VR16 1902-095 0 Diode Zen er 4.7V 5 U3 1820-672 1 IC MPU U4 5080-246 6 ROM programm ed fron t pa n el U6 1818-479 2 IC m emory U8 1820-272 4 IC SN74A LS573BN W3 1258-0 209 Jumper (J3) W5 081 ...

  • Agilent Technologies 6682A - page 93

    Replaceable Parts 95 Table 5- 6. A2 GPIB Board , Replace able Parts (se e Note) Ref. Desig. Agilent Part No. Description ELEC TRICAL PAR TS C122 0180-4 606 C apacitor 10,000 µ F C128 0160-4 281 Capacitor 2,20 0pF F101 2110-069 9 Fuse Su bminature 5 AM J101 1252-2320 Connector Receptacle (GPIB) J106 1251-4926 Connector Receptacle (Test Header) J107 ...

  • Agilent Technologies 6682A - page 94

    96 Replac eable Parts Table 5- 7. A3 FET A s sembly, Repla ceable Parts ( continued ) Ref. Desig. A gilent P art No. Description C244, 245 0160-680 6 CAP .lu F 400V C248 0160-4 832 CAP .0lu F 10% C258 0180-4 132 CAP 6.8u F 35V C301 0160-750 5 7uF+ - 5% 200V C302 0180-4 132 CAP 6.8u F 35V C303 0160-483 5 CAP .l uF 10% 50V C304, 305 0160-5 098 CAP .2 ...

  • Agilent Technologies 6682A - page 95

    Replaceable Parts 97 Table 5- 7. A3 FET A s sembly, Repla ceable Parts ( continued ) Ref. Desig. A gilent P art No. Description Q301, 302, 303, 304 1855-085 9 MOSFET 500V 20A Q311, 322, 333, 344 1855-085 9 MOSFET 500V 20A Q351, 352, 353, 354 1853-0 363 D45H5/D45H8/ 363 R201 0811-390 3 RES 150 O hm 5W N I R202 0699-020 8 RES 1 5% .25W CF R203 0683-5 ...

  • Agilent Technologies 6682A - page 96

    98 Replac eable Parts Table 5- 7. A3 FET A s sembly, Repla ceable Parts ( continued ) Ref. Desig. A gilent P art No. Description R271 0757-020 0 RES 5.62K 1% R272 0757-044 2 RES l0K 1% .125W R273, 274, 2 75 0757-043 7 RES 4.75K 1% R277 0698-363 3 RES 3905% 2W MO R301 0811-390 3 RES 150O hm 5W N I R302 0699-020 8 RES 1 5% .25W CF R303 0683-561 5 RES ...

  • Agilent Technologies 6682A - page 97

    Replaceable Parts 99 Table 5- 7. A3 FET A s sembly, Repla ceable Parts ( continued ) Ref. Desig. A gilent P art No. Description R383 0757-044 2 RES 10K 1% .125W R384, 385 8159-000 5 RES-ZER O OHMS T202 9100-435 0 XFMR -CURREN T T204 06624-80091 XF MR-PULS E T205 5080-223 8 XFMR-CUR S HARING T302 9100-435 0 XFMR -CURREN T T304 06624-80091 XF MR-PULS ...

  • Agilent Technologies 6682A - page 98

    100 Repla ceable Part s Table 5- 9. A5 DC Rail A s sembly, Rep laceable Parts Ref. Desig. Agilent Part No. Description ELEC TRICAL PAR TS C418 0160-40 48 CAP 0.02 2uF 20% C420, 421, 4 22 0160-7 606 CAP lu F 275V C427 0160-774 3 C-F .047u F 380V D420, 421, 422, 424, 4 25 5060-351 6 ASSY.- RECTIFIER DS420, 421 1990-0517 L ED F420 2110- 110 7 FUSE CL ...

  • Agilent Technologies 6682A - page 99

    Replaceable Parts 10 1 Table 5- 10. A6 Bias A ssembl y, Replaceabl e Parts (con tinued) Ref. Desig. Agilent Part No. Desc ription C823 0180-4 131 CAP 4.7uF 35V C824, 825 0180-3298 C- F 2200uF 50V C826 0160-4 834 CAP .047uF 10% C827 0180-3 587 CAP 1000uF 50V C828 0180-0 230 C- F luF 50V C829, 830, 8 31 0180-4129 CAP l uF 35V C841 0180-4 397 C- F 100 ...

  • Agilent Technologies 6682A - page 100

    102 Repla ceable Part s Table 5- 10. A6 Bias A ssembl y, Replaceabl e Parts (con tinued) Ref. Desig. Agilent Part No. Desc ription R842 0698-6 360 RES 10K .1% R843 0757-0 472 RES 200K 1% R844 0698-6 977 RES 30K .1% .125 R845, 847 0698-6360 RES 10K .1% R848 0698-6 977 RES 30K .1% .125 R849 0683-3 325 RES 3.3K 5% .25W R850 0698-6 977 RES 30K .1% .125 ...

  • Agilent Technologies 6682A - page 101

    Replaceable Parts 10 3 Table 5-11. A 7 Snubber A ssembl y , Replaceabl e Parts Ref. Desig. Agilent Part No. Desc ription ELEC TRICAL PAR TS C910, 911, 9 12, 913 6680A, 668 1A 0160- 016 2 CAP .022uF 10% 6682A 0160-6 896 CAP .015u F 10% 6683A 0160-4 845 CAP 6800 pF 10% 6684A 0160-6 162 CAP 4700 pF 10% R910, 911, 9 12, 913 6680A, 668 1A 0698- 3601 RES ...

  • Agilent Technologies 6682A - page 102

    104 Repla ceable Part s Table 5- 13. A9 Down Programmer/Slo w Sense, Rep laceable Part s Ref. Desig. Agilent Part No. Desc ription ELEC TRICAL PAR TS C950, 951 0160-425 9 CA P .22uF 10% C952, 953 0160-404 8 CA P .022uF 20% C956, 957 0160-4065 CAP .lu F 20% C958, 980 0160-4835 CAP .lu F 10% 50V D980, 981 1901-1098 DIO-IN4150 F980, 981 6680A, 668 1A ...

  • Agilent Technologies 6682A - page 103

    Replaceable Parts 10 5 Table 5- 14. A10 Cont rol Assembly, Rep laceable Parts Ref. Desig. Agilent Part No. Desc ription ELEC TRICAL PAR TS C500, 501, 5 02 0180-4129 CAP l uF 35V C503 0160-4 835 CAP .l uF 10% 50V C504 0180-4 129 CAP luF 35V C505 0180-4 131 CAP 4.7uF 35V C506 0160-4 835 CAP .l uF 10% 50V C507 0180-4 136 CAP l0uF 20V C508 0160-4 831 C ...

  • Agilent Technologies 6682A - page 104

    106 Repla ceable Part s Table 5- 14. A10 Cont rol Assembly, Rep laceable Parts (contin ued) Ref. Desig. Agilent Part No. Desc ription C588 0160-4 799 CAP 2.2pF 5% C589, 590 6680A, 668 1A not u sed 6682A, 668 3A, 6684A 0160-482 4 CAP 680pF 5% C591 6680A 0160-4 814 CAP 150pF 5% 6681A 0160-4 801 CAP l 00pF 5% 6682A, 683A , 6684A 0160- 4813 CA P 180pF ...

  • Agilent Technologies 6682A - page 105

    Replaceable Parts 10 7 Table 5- 14. A10 Cont rol Assembly, Rep laceable Parts (contin ued) Ref. Desig. Agilent Part No. Desc ription C639 0160-4 795 CAP 4.7pF C640 0160-4 835 CAP .l uF 10% 50V C641 0160-5 410 CAP 3300pF 5% C645 0160-4 805 CAP 47pF 5% l00V C648 0160-4 831 CAP 4700pF 10% C650 0160-4 833 CAP .022uF 10% C651 0160-7 277 CAP 2.2uF 50V C6 ...

  • Agilent Technologies 6682A - page 106

    108 Repla ceable Part s Table 5- 14. A10 Cont rol Assembly, Rep laceable Parts (contin ued) Ref. Desig. Agilent Part No. Desc ription R506 0757-0 289 RES 13.3K 1% R507 0698-3 155 RES 4.64K 1% R508 0698-6 323 RES 100.1% R509 0757-0 442 RES 10K 1% .125W R510 0757-0 289 RES 13.3K 1% R511 0698-3 155 RES 4.64K 1% R512 0757-0 472 RES 200K 1% R513 0757-0 ...

  • Agilent Technologies 6682A - page 107

    Replaceable Parts 10 9 Table 5- 14. A10 Cont rol Assembly, Rep laceable Parts (contin ued) Ref. Desig. Agilent Part No. Desc ription R570, 580 0757-0424 RES l.lK 1% R581 0757-0 407 RES 200 1% .125W R582, 583 0698-4486 RES 24.9K 1% R584 0757-0 472 RES 200K 1% R585 0757-0 434 RES 3.65K 1% R586 0757-0 472 RES 200K 1% R587 0757-0 407 RES 200 1% .125W R ...

  • Agilent Technologies 6682A - page 108

    110 Repla ceable Part s Table 5- 14. A10 Cont rol Assembly, Rep laceable Parts (contin ued) Ref. Desig. Agilent Part No. Desc ription R624 0757-0 453 RES 30.1K 1% R625 6680A, 668 1A 0698- 3455 RES 261K 1% 6682A 0757-0 461 RES 68.1K 1% 6683A, 668 4A 0699- 1972 RES 1.74M 1% R626 6680A, 668 1A 0698- 3455 RES 261K 1% 6682A 0699-008 8 RE S 1.21M 1% 6683 ...

  • Agilent Technologies 6682A - page 109

    Replaceable Parts 11 1 Table 5- 14. A10 Cont rol Assembly, Rep laceable Parts (contin ued) Ref. Desig. Agilent Part No. Desc ription R666 6680A 0698-891 3 RE S 1.5M 1% 6681A, 668 2A 0683- 2255 RES 2.2M 1% 6683A 0683-475 5 RE S 4.7M 1% 6684A 0683-565 5 RE S 5.6M 1% R667 6680A 0757-0 465 RES l00K 1 6681A 0757-0 462 RES 75K 1% 6682A, 668 3A 0698- 3455 ...

  • Agilent Technologies 6682A - page 110

    112 Repla ceable Part s Table 5- 14. A10 Cont rol Assembly, Rep laceable Parts (contin ued) Ref. Desig. Agilent Part No. Desc ription R684 6680A 0757-0 280 RES lK 1% 6681A 0757-0 289 RES lK 1% 6682A 0757-0 430 RES 2.21K 1% 6683A 0698-3 496 RES 3.57K 1% 6684A 0757-0 436 RES 4.32K 1% R685 6680A 0757-0 280 RES lK 1% 6681A 0757-0 289 RES lK 1% 6682A 07 ...

  • Agilent Technologies 6682A - page 111

    Replaceable Parts 11 3 Table 5- 14. A10 Cont rol Assembly, Rep laceable Pa rts (contin ued) Ref. Desig. Agilent Part No. Desc ription R709 6680A 0757-0 468 RES 130K 6681A, 668 2A 0757- 0464 RES 90.9K 6683A, 668 4A 0757- 0464 RES 90.9K R710 6680A 0698-5 091 RES 45K 6681A, 668 2A 0698- 3160 RES 31.6K 6683A, 668 4A 0698- 3160 RES 31.6K R711 0698-5 091 ...

  • Agilent Technologies 6682A - page 112

    114 Repla ceable Part s Table 5- 14. A10 Cont rol Assembly, Rep laceable Parts (contin ued) Ref. Desig. Agilent Part No. Desc ription U506 5080-2 305 PRGMD- IC, SEC U507 1820-307 9 IC MC 74HC138N U510, 511, 512 1826-2187 IC-C ONVERTER,DIA U513, 514, 515 1826-1 896 IC-L INEAR U516, 517 1826-1370 IC 365 U518 1820-308 1 IC MC 74HC74N U520 1826-1 231 D ...

  • Agilent Technologies 6682A - page 113

    Diagrams 115 6 Diagrams Introduction This chapt er contai ns draw ings and diag rams for t roublesh ooting an d maintain ing Agilent Series 668xA Po w er Supplies. Unless otherwise specified, a drawing or diagram applies to all m odels of the series. W iring conn ections to external equipment are sh own in the Power Supply Operating Manual. Chapter ...

  • Agilent Technologies 6682A - page 114

    116 Diag rams Table 6- 2. Signal Name M nemonics Mnemonic Description Mnemonic Description A(0)--A(15) Addres s lines MSRQ Microprocessor se rvice request AD (O)--AD(7) Addres s bus NDAC Not data accepted (GPIB) AMB_SENSE Ambient temperature sense NEG_IMO N Negati ve curr ent mo nitor ANA(0)--ANA(7) Analog Signal readback bu s NRF D Not ready or da ...

  • Agilent Technologies 6682A - page 115

    Diagrams 117 Table 6- 3. Test Point s TEST POINT No. & Loc. Signal Tested Measurement and Conditions A2 GPIB BOARD J106- 4 Prim ary/chassis g round C onnect m eter or scope comm o n h ere. Then make measure ments at test points throug h . U101- 1 + 5V primary bias + 5V + 0.2V U101-6 PCLR Goes h igh for approxim ately 40 ms at pow er on, then go ...

  • Agilent Technologies 6682A - page 116

    118 Diag rams Table 6-3. Test Points (continued) TEST POINT No. & Loc. Signal Tested Measurement and Conditions Bias Board (c ontinued) U308-1 PREF +2.5V U308-5 RESET* Held low for approxim ately 50 ms at power- on, then goes high. U311-7 FAN DETECT +3V D317 -25V +3V U311-2 FAN_PWN +0.6V A3 FET Bo ard Test p oints thr ough are on the A3 FET Boa ...

  • Agilent Technologies 6682A - page 117

    Diagrams 119 Table 6-3. Test Points (continued) TEST POINT No. & Loc. Signal Tested Measurement and Conditions A10 Cont rol Board (continued) U600-10 DIVIDER CLOCK (Sheet 3) See Figure 6-1 U601-6 DIVIDER RESET (Sheet 3) See Figure 6-1 U601-3 ON LA TCH CLOCK (Sheet 3) See Figure 6-1 U604-3 ON LA TCH (Sheet 3) See Figure 6-1 U603-3 PWM_EN (Sheet ...

  • Agilent Technologies 6682A - page 118

    120 Diag rams Figure 6-1. Test Poin t Waveforms f or Table 6-3 ...

  • Agilent Technologies 6682A - page 119

    Diagrams 121 Figure 6-2. Circuit Board Cabling Diagram ...

  • Agilent Technologies 6682A - page 120

    122 Diag rams Figure 6-3. A1 Front Panel Board, Component and Test Point Location ...

  • Agilent Technologies 6682A - page 121

    Figure 6-4. A1 Front Panel Board, Schematic Diagram ...

  • Agilent Technologies 6682A - page 122

    Figure 6-5. LED Board, Component and Test Point Location Figure 6-6. LED Board, Schematic Diag ram ...

  • Agilent Technologies 6682A - page 123

    Figure 6-7. A2 GPIB Board, Component Location ...

  • Agilent Technologies 6682A - page 124

    2 3 4 1 6 5 7 8 Figure 6-8. A2 GPIB Board , Schematic Diagram ...

  • Agilent Technologies 6682A - page 125

    Figure 6-9. A3 FET Board, Component and Test Point Location ...

  • Agilent Technologies 6682A - page 126

    Figure 6-1 0. A3 FET Board , Schematic Diagram (sheet 1 of 2) ...

  • Agilent Technologies 6682A - page 127

    Figure 6-1 0. A3 FET Board , Schematic Diagram (sheet 2 of 2) ...

  • Agilent Technologies 6682A - page 128

    Figure 6-11. A4 AC Input Board, Component and Test Point Location 9 10 11 12 ...

  • Agilent Technologies 6682A - page 129

    Figure 6-12. A4 AC Input Board, Schematic Diagram ...

  • Agilent Technologies 6682A - page 130

    Figure 6-13. A5 DC Rail Board, Component and T est Point Loc ation 13 14 ...

  • Agilent Technologies 6682A - page 131

    Figure 6-1 4. A5 DC Rail Bo ard, Schematic Diagram 13 14 ...

  • Agilent Technologies 6682A - page 132

    Figure 6-15. A6 Bias Board, Component and Test Point Location 15 16 17 18 19 ...

  • Agilent Technologies 6682A - page 133

    Figure 6-1 6. A6 Bias Board , Schematic Di agram (She et 1of 2) 19 ...

  • Agilent Technologies 6682A - page 134

    Figure 6-1 6. A6 Bias Board , Schematic Di agram (She et 2 of 2) 15 16 17 18 ...

  • Agilent Technologies 6682A - page 135

    Figure 6-1 7. Power M esh, Schemati c Diagram, M odels 6680 A , 6681 A Only ...

  • Agilent Technologies 6682A - page 136

    Figure 6-1 8. Power M esh, Schemati c Diagram M odels 6682 A , 6683 A, 6684 A O nly ...

  • Agilent Technologies 6682A - page 137

    Figure 6-19. A7 Snubber Board, Component Location Figure 6-20. A7 Snubber Board, Schematic Diagram ...

  • Agilent Technologies 6682A - page 138

    Figure 6-21. A8 Fast Sense Board, Component Location Figure 6-2 2. A8 Fast Sense Board, Schematic Di agram ...

  • Agilent Technologies 6682A - page 139

    Figure 6-23. A9 Down Programming/Slow Sense, Component Location ...

  • Agilent Technologies 6682A - page 140

    Figure 6-24. A9 Down Programming/Slow Sense, Schematic Diagram ...

  • Agilent Technologies 6682A - page 141

    Figur e 6-25. A 10 Contr o l Boa r d, Compone nt a nd T es t Po int Loc at ion 47 55 44 41 42 46 48 43 63 53 51 50 49 45 38 36 60 62 61 59 54 52 57 58 56 64 37 21 36 22 20 39 40 ...

  • Agilent Technologies 6682A - page 142

    Figure 6-2 6. A10 Control Board, Schemat ic Diagram ( Sheet 1 of 4) 21 22 20 36 37 38 63 ...

  • Agilent Technologies 6682A - page 143

    Figure 6-2 6. A10 Control Board, Schemat ic Diagram ( Sheet 2 of 4) 64 40 39 ...

  • Agilent Technologies 6682A - page 144

    Figure 6-2 6. A10 Control Board, Schemat ic Diagram ( Sheet 3 of 4) 56 61 60 58 57 59 54 52 53 50 51 49 62 55 65 66 ...

  • Agilent Technologies 6682A - page 145

    Figure 6-2 6. A10 Control Board, Schemat ic Diagram ( Sheet 4 of 4) 48 43 47 42 41 39 46 45 44 40 ...

  • Agilent Technologies 6682A - page 146

    Backdating 149 A Backdating Manual backdat ing descri bes changes that must be m ade to this m anual for pow er suppli es whose seri al numbers are l ower than those listed in the title page to this manual. Look in th e following table and locate your Agilent model. Then look at each serial number listed for this group. If the serial num ber of you ...

  • Agilent Technologies 6682A - page 147

    150 Backd ating In Table 5-9 A5 DC Rail Board DELET E C418, 0. 022uF 250VA C "Y" rated P/N 01 60-4048 Fus e Clips , REF F420 & 421 1/4" P/N 21 10-0726, qt y , 4. ADD Fus e Holder, RE F F420 & 421, 5 x 30mm P/N 2110-0689, qty 2. CHANGE F420 & 421, from 0.5 A 500V P/N 2110-09 34 to 0.5A 500V 5x30mm P/N 2110-0921. CHANGE 3 I ...

  • Agilent Technologies 6682A - page 148

    Backdating 151 Table A-1. A 2 GPIB Parts List Ref Desig. Agilent Part No. Description ELEC TRICAL PAR TS C102-105 0160-482 2 Capacitor 1000pF 5% C106 0180-0 155 Capacitor 2.2 µ F 20V C107,108 0160- 4787 Capacit or 22pF 5% 100V C109-111 ,114,115,121 0160-542 2 Capacitor 0.047 µ F 20% C122 0180-332 5 Capacitor 25V C123 0160-482 2 Capacitor 1000pF 5 ...

  • Agilent Technologies 6682A - page 149

    152 Backd ating Tab le A -1. A 2 GPIB Parts List (continued) Ref Desig. Agilent Part No. Description ELEC TRICAL PAR TS TB101 0360-2 312 Terminal block (digi tal cont rol) U101 1826-046 8 IC MC3423PI U106 5080-2152 IC DR OM GPIB U108 1818-4111 IC MCM 6164C 55 U109 1820-6789 IC in terface U110,111 1990- 0444 IC Opto i solator U112 1820-321 0 IC 68B5 ...

  • Agilent Technologies 6682A - page 150

    Backdating 153 Figure A-1. A2 GPIB Component Parts List ...

  • Agilent Technologies 6682A - page 151

    Index 155 Index A A1 Front Panel Board, tes t header .............................................................................................. ................................ 57 A2 GPIB Board, test header ..................................................................................................... ................................... 5 ...

  • Agilent Technologies 6682A - page 152

    156 Index CV source eff ect, defined...................................................................................................... ...................................... 17 CV source eff ect, testing ...................................................................................................... ....................................... ...

  • Agilent Technologies 6682A - page 153

    Index 157 UART PARITY .................................................................................................................... ............................... 35 error mes sage, selftest ........................................................................................................ ......................................... 35 e ...

  • Agilent Technologies 6682A - page 154

    158 Index Mnemonics signa l names ......................................................................................................... ................................. 140 mutual coupling, test lead ..................................................................................................... ...................................... 14 N ...

  • Agilent Technologies 6682A - page 155

    Index 159 load ........................................................................................................................... ........................................... 12 resistor, cu rrent monitor ...................................................................................................... .................................. ...

  • Agilent Technologies 6682A - page 156

    160 Index Troubles hooting test points .................................................................................................................... ....................................... 142 troubles hooting chart output h eld high ............................................................................................................. ...

Produzent Agilent Technologies Kategorie Video Gaming Accessories

Dokumente, die wir vom Produzenten des Geräts Agilent Technologies 6682A erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Agilent Technologies
- Bedienungsanleitungen 6682A
- Produktkarten Agilent Technologies
- Informationsbroschüren
- oder Energieetiketten Agilent Technologies 6682A
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Agilent Technologies 6682A.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Agilent Technologies 6682A, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Agilent Technologies 6682A. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Agilent Technologies 6682A ansehen.

Die komplette Bedienungsanleitung des Geräts Agilent Technologies 6682A, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Agilent Technologies 6682A hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Agilent Technologies 6682A verständlich ist.

Eine gänzliche Bedienungsanleitung von Agilent Technologies sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Agilent Technologies 6682A bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Agilent Technologies 6682A befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Agilent Technologies 6682A, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Agilent Technologies 6682A - die uns die ersten Schritte während der Nutzung von Agilent Technologies 6682A erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Agilent Technologies 6682A hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Agilent Technologies 6682A im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Agilent Technologies 6682A?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Agilent Technologies 6682A nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Agilent Technologies 6682A hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)