    Page 1 12821-6-0406 VENTED ROOM HEA TER MODELS RH-25-6 RH-35-6 EFFECTIVE DA TE APRIL 2006 INST ALLA TION INSTRUCTIONS AND OWNER’S MANUAL — Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. — WHA T TO DO IF YOU SMELL GAS • Do not try to light any appli- ance. • Do no t t o ...

  • Langley/Empire RH-35-6 - page 2

    Page 2 12821-6-0406 SECTION P AGE Important Safety Information ......................................................................................................................3 Safety Information for Users of LP Gas ......................................................................................................4 Introduction ........... ...

  • Langley/Empire RH-35-6 - page 3

    Page 3 12821-6-0406 • Due to high temperatures, the r oom heater should be located out of traffic and away fr om furnitur e and drap- eries. • Childr en and adults should be alerted to the hazards of high surface temperatur e and should stay away to avoid burns or clothing ignition. • Y oung children should be carefully supervised when they ...

  • Langley/Empire RH-35-6 - page 4

    Page 4 12821-6-0406 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor . Sometimes other odors in the area ...

  • Langley/Empire RH-35-6 - page 5

    Page 5 12821-6-0406 Introduction Always consult your local Building Department regarding regu- lations, codes or ordinances which apply to the installation of a vented room heater . Instructions to Installer 1. Installer must leave instruction manual with owner after instal- lation. 2. Installer must have owner fill out and mail warranty card sup- ...

  • Langley/Empire RH-35-6 - page 6

    Page 6 12821-6-0406 Note: Never use plastic pipe. Check to confirm whether your local codes allow copper tubing or galvanized. Note: Since some municipalities have additional local codes, it is always best to consult your local authority and installation code. The use of the following gas connectors is recommended: — ANS Z21.24 App lianc e Conn ...

  • Langley/Empire RH-35-6 - page 7

    Page 7 12821-6-0406 Clearances: When facing the front of the room heater the mini- mum clearances to combustible construction (material) are the following: Right side 6 inches (152mm). Left side 6 inches (152mm). Recommend 18 inches (457mm) on left side for servicing. Do not install in alcove or closet. No horizontal projection above heater permitt ...

  • Langley/Empire RH-35-6 - page 8

    Page 8 12821-6-0406 This heater must be properly connected to a venting system. This heater is equipped with a vent safety shutoff system. W arning: Operation of this heater , when not connected to a properly installed and maintained venting system or tampering with the vent safety shutoff system, can result in carbon monoxide (CO) poisoning and po ...

  • Langley/Empire RH-35-6 - page 9

    Page 9 12821-6-0406 1. STOP! Read the safety information to the left of this label. 2. Set thermostat to lowest setting. 3. T urn off all electric power to the appliance. (If applicable) 4. Remove access panel (front panel). 5. Push in gas control knob slightly and turn clockwise to “OFF”. Do not force. 6. W ait ten (10) minutes to clear out an ...

  • Langley/Empire RH-35-6 - page 10

    Page 10 12821-6-0406 The correct flame will be almost horizontal, blue and will extend past the thermocouple 1/4" (6mm). The flame will surround the thermocouple just below the tip. On Propane (LP-gas) slight yellow might occur where the pilot flame and the burner flame meet. Natural gas pilots require adjusting when the inlet pressure is ...

  • Langley/Empire RH-35-6 - page 11

    Page 1 1 12821-6-0406 T o Remove Main Burner 1. Disconnect the thermocouple and pilot supply line at the pilot burner . 2. Unscrew the nut on the orifice fitting union. Orifice fitting is threaded into the main burner . 3. Remove screw on each side of the main burner and lift out. T o Remove Main Burner Orifice 1. Unscrew the nut on the orifi ...

  • Langley/Empire RH-35-6 - page 12

    Page 12 12821-6-0406 INDEX NO. P AR T NUMBER DESCRIPTION 1 R-6096 Knob & Adaptor Set 2 1 1700 Control Rod Bracket 3 R-2706 ECO Switch 4 R-8195 ECO W ire Assembly 5 1 1699 Control Rod 6 R-6104 Gas V alve (LPG) 6 R-6103 Gas V alve (Nat) 7 1 1697 V alve Bracket 8 RH-705 Casing Side 9 RH-708 Air Inlet Baffle 10 P-86-37 Main Burner Orifice, (RH-35 ...

  • Langley/Empire RH-35-6 - page 13

    Page 13 12821-6-0406 ...

  • Langley/Empire RH-35-6 - page 14

    Page 14 12821-6-0406 DRB-1 For V ented Room Heaters Models RH-25-(1, 2, 4, 5, 6) and RH-35-(1, 2, 4, 5, 6) Dir ect V ent W all Furnaces DV -25-(1, 2)SG and DV -35-(1, 2)SG Installing Optional DRB-1 Blower 1. For RH-25-(1, 2, 4, 5, 6) and RH-35-(1, 2, 4, 5, 6) , remove casing front. 1. For DV -25-(1, 2)SG and DV -35-(1, 2)SG , remove casing front an ...

  • Langley/Empire RH-35-6 - page 15

    Page 15 12821-6-0406 Code, CSA C22.1 , if an external electrical source is utilized. This appliance is equipped with a three-pr ong [grounding] plug for your protection against shock hazard and should be plugged directly into a pr operly grounded three-pr ong receptacle. Do not cut or remove the grounding prong fr om this plug. For an ungrounded re ...

  • Langley/Empire RH-35-6 - page 16

    Page 16 12821-6-0406 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.com www .empirecomfort.com SER VICE NOTES ...

Produzent Langley/Empire Kategorie Electric Heater

Dokumente, die wir vom Produzenten des Geräts Langley/Empire RH-35-6 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Langley/Empire
- Bedienungsanleitungen RH-35-6
- Produktkarten Langley/Empire
- Informationsbroschüren
- oder Energieetiketten Langley/Empire RH-35-6
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Langley/Empire RH-35-6.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Langley/Empire RH-35-6, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Langley/Empire RH-35-6. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Langley/Empire RH-35-6 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Langley/Empire RH-35-6, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Langley/Empire RH-35-6 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Langley/Empire RH-35-6 verständlich ist.

Eine gänzliche Bedienungsanleitung von Langley/Empire sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Langley/Empire RH-35-6 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Langley/Empire RH-35-6 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Langley/Empire RH-35-6, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Langley/Empire RH-35-6 - die uns die ersten Schritte während der Nutzung von Langley/Empire RH-35-6 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Langley/Empire RH-35-6 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Langley/Empire RH-35-6 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Langley/Empire RH-35-6?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Langley/Empire RH-35-6 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Langley/Empire RH-35-6 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)