    1 W415-0809 / A / 05.10.10 INST ALLER: LEA VE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RET AIN THIS MANUAL FOR FUTURE REFERENCE. INST ALLA TION AND OPERA TING INSTRUCTIONS 1.3A Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada / 103 Miller Drive, Crittenden, Kentucky , USA, 41030 Phone (705)721-1212 • Fax (705)722-6031 • www .napole ...

  • Napoleon Fireplaces GVFL18P - page 2

    2 W415-0809 / A / 05.10.10 NOTE: Changes, other than editorial, are denoted by a vertical line in the margin. T ABLE OF CONTENTS 1.0 INST ALLA TION OVERVIEW 3 2.0 INTRODUCTION 4 2.1 GENERAL INSTRUCTIONS 5 2.2 GENERAL INFORMA TION 6 2.3 MINIMUM APPLIANCE SIZE 6 2.4 RA TING PLA TE INFORMA TION 7 3.0 INST ALLA TION 8 3.1 INST ALLING IN AN UNVENTED APP ...

  • Napoleon Fireplaces GVFL18P - page 3

    3 W415-0809 / A / 05.10.10 1.0 INST ALLA TION O VER VIEW Andiron, see “ ANDIRON AND GRA TE ASSEMBL Y” sec tion. Logs , see “L OG PLACEMENT” section. Media, see “MEDIA ” section. Rating Plate, see “RA TING PLA TE INFORMA TION” section. ...

  • Napoleon Fireplaces GVFL18P - page 4

    4 W415-0809 / A / 05.10.10 3.12 ! W ARNING • THIS APPLIANCE IS HOT WHEN OPERA TED AND CAN CAUSE SEVERE BURNS IF CONT ACTED. • ANY CHANGES T O THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED. • Under no circumstances should this appliance be modi fi ed. • Do not operate appliance before reading and understanding operating ...

  • Napoleon Fireplaces GVFL18P - page 5

    5 W415-0809 / A / 05.10.10 2.1 GENERAL INSTRUCTIONS Thoroughly clean the chimney , fl ue and existing appliance before installing the new appliance into it. Do not burn solid fuels in any appliance that is equipped with this gas log set. The installation of this appliance must conform with local codes or in the absence of local codes with the Nati ...

  • Napoleon Fireplaces GVFL18P - page 6

    6 W415-0809 / A / 05.10.10 2.2 GENERAL INFORMA TION CARBON MONOXIDE POISONING MA Y LEAD TO DEA TH EARL Y SIGNS OF CARBON MONOXIDE POISONING RESEMBLE THE FLU, WITH HEADACHE, DIZZINESS AND/OR NAUSEA. IF YOU HA VE THESE SIGNS, THE APPLIANCE MA Y NOT BE WORKING PROPERL Y . GET FRESH AIR A T ONCE! HA VE APPLIANCE SER VICED. SOME PEOPLE--PREGNANT WOMEN, ...

  • Napoleon Fireplaces GVFL18P - page 7

    7 W415-0809 / A / 05.10.10 2.4 RA TING PLA TE INFORMA TION THIS APPLIANCE IS NOT FIELD CONVERTIBLE FOR USE WITH OTHER GASES. REFERENCE # W/N 15533 THE RA TING PLA TE IS CHAINED TO THE PIEZO IGNIT OR BRACKET AND SHOULD BE TUCKED UNDER THE ENTIRE ASSEMBL Y ...

  • Napoleon Fireplaces GVFL18P - page 8

    8 W415-0809 / A / 05.10.10 3.0 INST ALLA TION 3.1.1 COMB USTION AND VENTILA TION AIR PRO VISIONS 17.1A This appliance shall not be installed in a con fi ned space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air . The National Fuel Gas Code, ANSI Z223.1 / NFP A 54 de fi nes a con fi ned s ...

  • Napoleon Fireplaces GVFL18P - page 9

    9 W415-0809 / A / 05.10.10 19.2 EXAMPLE 1: In this example, because there is no door to the adjoining room, the volume of the adjoining room may be added to the volume of the room with the heater to get a total uncon fi ned space. The total uncon fi ned space: 800 + 1200 = 2000 cubic feet. Maximum BTU/h: 2000x1000 = 40,000 BTU/h 50 19.3 EXAMPLE 2 ...

  • Napoleon Fireplaces GVFL18P - page 10

    10 W415-0809 / A / 05.10.10 3.2 INST ALLING IN A VENTED APPLICA TION 3.2.1 D AMPER ST OP INST ALLA TION DAMPER STOP DAMPER The damper must be permanently locked in position to prevent full closure and to provide a minimum fl ue opening. V arious methods for locking the damper may be used but may be restricted from region to region and it is import ...

  • Napoleon Fireplaces GVFL18P - page 11

    11 W415-0809 / A / 05.10.10 3.3 GAS PIPING ! W ARNING DO NOT CONNECT EITHER THE W ALL SWITCH, THERMOST A T OR GAS V AL VE TO ELECTRICITY (1 10 VOL TS). This appliance and it’s appliance main valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ PSI (3.5kPa) This a ...

  • Napoleon Fireplaces GVFL18P - page 12

    12 W415-0809 / A / 05.10.10 4.2 LOG PLA CEMENT Failure to position these logs in accordance with these diagrams or failure to use parts speci fi cally approved with this appliance may result in property damage or personal injury . Do not place glowing embers, charcoal embers, vermiculite or charcoal lumps on this burner . ! W ARNING Phazer TM logs ...

  • Napoleon Fireplaces GVFL18P - page 13

    13 W415-0809 / A / 05.10.10 4.3 LOGO PLA CEMENT LO G O ½" LOGO ½" Remove the backing of the logo supplied. Centre the logo on the front of the appliance, ½” in from the left side, as shown. 4.4 MEDIA 4.4.1 Place lava or ember rock around the base of the appli- ance, making sure not to block any burner ports or valve access. Retain a ...

  • Napoleon Fireplaces GVFL18P - page 14

    14 W415-0809 / A / 05.10.10 5.0 OPERA TING INSTR UCTIONS If the appliance is equipped with decorative glass doors, they must be fully opened when operating this gas log set. 5.1 LIGHTING INSTRUCTIONS 1 3 4 5 2 5.1.1 Locate the pilot burner at the rear of the log set on the right side. 5.1.2 T urn the gas control knob to the pilot setting (on the le ...

  • Napoleon Fireplaces GVFL18P - page 15

    15 W415-0809 / A / 05.10.10 FOR Y OUR SAFETY READ BEFORE LIGHTING: Ɣ This appliance is equipped with a pilot which must be lit by hand while following these instructions exactly . Ɣ Before operating smell all around the appliance area for gas and next to the floor because some gas is heavier than air and will settle on the floor . Ɣ Use only ...

  • Napoleon Fireplaces GVFL18P - page 16

    16 W415-0809 / A / 05.10.10 7.0 ADJUSTMENTS 7.1 AIR SHUTTER ! W ARNING CARBON CAN BE DISTRIBUTED IN SURROUNDING LIVING AREAS IF THE AIR SHUTTER IS IMPROPERL Y ADJUSTED. F AILURE TO KEEP THE PRIMAR Y AIR OPENING(S) OF THE BURNER (S) CLEAN MA Y RESUL T IN SOOTING AND PROPERTY DAMAGE. LOG SET AIR SHUTTER FUEL NG LP GVFL18 9/32” 7/16” GVFL24 9/32? ...

  • Napoleon Fireplaces GVFL18P - page 17

    17 W415-0809 / A / 05.10.10 9.0 REPLA CEMENTS Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Authorized dealer / distributor . FOR W ARRANTY REPLACEMENT P ARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM. When ordering ...

  • Napoleon Fireplaces GVFL18P - page 18

    18 W415-0809 / A / 05.10.10 7 2 1 4 3 13 12 8 10 11 9 20 15 1 5 6 16 17 ...

  • Napoleon Fireplaces GVFL18P - page 19

    19 W415-0809 / A / 05.10.10 10.0 TR OUBLE SHOO TING SYMPTOM PROBLEM TEST SOLUTION Main burner goes out; pilot stays on. Pilot fl ame is not large enough or not engul fi ng the thermopile. - Ensure adequate supply pressure. - Replace pilot assembly . Thermopile shorting / loose connection. - Clean thermopile connection to the valve. Reconnect. - R ...

  • Napoleon Fireplaces GVFL18P - page 20

    20 W415-0809 / A / 05.10.10 SYMPTOM PROBLEM TEST SOLUTION Pilot burning; no gas to main burner; gas knob is on ‘HI’; wall switch / thermostat is on. Thermostat or switch is defective. - Connect a jumper wire across the wall switch terminals; if main burner lights, replace switch / thermostat. W all switch wiring is defective. - Disconnect wires ...

  • Napoleon Fireplaces GVFL18P - page 21

    21 W415-0809 / A / 05.10.10 SYMPTOM PROBLEM TEST SOLUTION Flames are consistently too large or too small. Carboning occurs. Unit is over- fi red or under- fi red. - Check pressure readings: - Inlet pressure can be checked by turning screw (A) counter-clockwise 2 or 3 turns and then placing pressure gauge tubing over the test point. Check with bur ...

  • Napoleon Fireplaces GVFL18P - page 22

    22 W415-0809 / A / 05.10.10 NAPOLEON® warrants its products against manufacturing defects to the original purchaser only . Registering your warranty is not necessary . Simply provide your proof of purchase along with the model and serial number to make a warranty claim. NAPOLEON® reserves the right to have its representative inspect any product o ...

  • Napoleon Fireplaces GVFL18P - page 23

    23 W415-0809 / A / 05.10.10 12.0 SER VICE HIST OR Y 43.1 ...

  • Napoleon Fireplaces GVFL18P - page 24

    24 W415-0809 / A / 05.10.10 44.1 13.0 NO TES ...

Produzent Napoleon Fireplaces Kategorie Indoor Fireplace

Dokumente, die wir vom Produzenten des Geräts Napoleon Fireplaces GVFL18P erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Napoleon Fireplaces
- Bedienungsanleitungen GVFL18P
- Produktkarten Napoleon Fireplaces
- Informationsbroschüren
- oder Energieetiketten Napoleon Fireplaces GVFL18P
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Napoleon Fireplaces GVFL18P.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Napoleon Fireplaces GVFL18P, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Napoleon Fireplaces GVFL18P. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Napoleon Fireplaces GVFL18P ansehen.

Die komplette Bedienungsanleitung des Geräts Napoleon Fireplaces GVFL18P, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Napoleon Fireplaces GVFL18P hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Napoleon Fireplaces GVFL18P verständlich ist.

Eine gänzliche Bedienungsanleitung von Napoleon Fireplaces sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Napoleon Fireplaces GVFL18P bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Napoleon Fireplaces GVFL18P befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Napoleon Fireplaces GVFL18P, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Napoleon Fireplaces GVFL18P - die uns die ersten Schritte während der Nutzung von Napoleon Fireplaces GVFL18P erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Napoleon Fireplaces GVFL18P hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Napoleon Fireplaces GVFL18P im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Napoleon Fireplaces GVFL18P?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Napoleon Fireplaces GVFL18P nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Napoleon Fireplaces GVFL18P hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)