    Instruction Manual Athena 6050 Temperature Controllers -THENIL ...

  • Athena Technologies 6050 - page 2

    INSTRUCTION MANUAL SPECIFICATIONS: Inputs: Line Voltage Sensor Power Consumption Ranges Available Accuracy: Temperature Stability Cold end tracking Operating ambient for rated accuracy Maximum T/C lead resistance for rated accuracy Series mode noise rejection: Common mode noise rejection T/C break protection: Dual display: ATHENA 6050 Automatic Tun ...

  • Athena Technologies 6050 - page 3

    Display update rate: 5 times per second Filtering: Analog and digital filtering techniques increase stability of process and display. °F/°C: output: -B Relay (time proportioning) -F Current proportional -S Pulsed voltage -T Triac time proportional Filtered LED display: T/C linearization: Connections: Dimensions: Mounting: Weight: Internal switch ...

  • Athena Technologies 6050 - page 4

    3 ...

  • Athena Technologies 6050 - page 5

    FRONT PANEL AOJUSTMENTS Touch Key 1 Index: Allows the following adjustments to be selected. 1) Set point temperature O-14OO'F (760°C) O-2500°F (O-137O°C) 2) Heat cycle time 3) Prop. Band (indicated *1 to 120 seconds as gain) 0.25-25% of span 4) Rate with tracking reset **4-255 seconds 5) Auto Tune (AT) Up/Down keys: increases/decreases valu ...

  • Athena Technologies 6050 - page 6

    3. 4. Loss of power or turn-off during warm-up requires a re-start from ambient. Change of state processes, i.e. solid to liquid or liquid to gas, may introduce erroneous tuning parameters during process warm-up. 1. Accurately measures, linearizes and displays temperature in °F and °C. 2. Automatically calculates and displays parameters-heat gain ...

  • Athena Technologies 6050 - page 7

    ...

  • Athena Technologies 6050 - page 8

    Output Modules The Athena 6050 offers users field interchangeable output modules. This unique feature makes it possible to fill output requirements for a variety of applications with a single controller model. Module Type B: This 7A/5A relay (at 120/240 Vac) is used for driving resistive heaters. NOTE: Do not use this output module with mechanical ...

  • Athena Technologies 6050 - page 9

    INTERNAL SWITCHES Damping Control -To allow the controller to provide automatic tuning for processes with varying heating characteristics and with varying heating capabilities, the 6050 offers three damping choices: High damping: for over-powered heating systems, systems with multiple heat lags, and/or poor coupling between the heater and the tempe ...

  • Athena Technologies 6050 - page 10

    THERMOCOUPLE PLACEMENT Proper thermocouple placement can eliminate many problems in the system. The probe should be placed so that it can detect any temperature change with minimal thermal lag. In a process that requires fairly constant heat output, the probe should be placed close to the heater. In processes where the heat demand is variable, the ...

  • Athena Technologies 6050 - page 11

    OPERATING INSTRUCTIONS How to Start the automatic tuning procedure STEP 1: Energize the unit and proceed immediately to step 2. STEP 2: Place the unit on standby by holding the "Index" button until the "Autotune" LED lights then press the Cancel button. The unit is now ready for set point and cycle time entry. STEP 3: To enter a ...

  • Athena Technologies 6050 - page 12

    How to override automatic tuning parameters It is possible to set or fine tune three mode parameters manually on the 6050. To manually enter parameters: 1) Press "Index" button until the LED for the desired parameter lights. 2) Enter the new parameter using the up or down key. 3) Press the "enter" button. The new parameters will ...

  • Athena Technologies 6050 - page 13

    TROUBLE SHOOTING Front dark - no instrument power. Process display shows CCCC - Open thermcouple. Short terminals 1 and 2. Process display should indicate temperature at back of case. Repair or replace thermocouple. About Half or Twice Expected Reading - Check position of °C/°F switch. Short 1 and 2 to read room temperature. 22-30 is °C, 70-85 i ...

  • Athena Technologies 6050 - page 14

    WARRANTY This equipment is warranted to be free from defects of material and workmanship. It is sold subject to our mutual agreement that the liability of Athena Controls, Inc. is to replace and/or repair at its factory, provided the equipment is returned, transportation prepaid within (2) years of its purchase. The purchaser agrees that Athena Con ...

  • Athena Technologies 6050 - page 15

    dTHENd Controls, Inc., 5145 Campus Drive Plymouth Meeting, PA 19462 (215) 828-2490 ...

Produzent Athena Technologies Kategorie Weather Radio

Dokumente, die wir vom Produzenten des Geräts Athena Technologies 6050 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Athena Technologies
- Bedienungsanleitungen 6050
- Produktkarten Athena Technologies
- Informationsbroschüren
- oder Energieetiketten Athena Technologies 6050
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Athena Technologies 6050.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Athena Technologies 6050, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Athena Technologies 6050. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Athena Technologies 6050 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Athena Technologies 6050, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Athena Technologies 6050 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Athena Technologies 6050 verständlich ist.

Eine gänzliche Bedienungsanleitung von Athena Technologies sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Athena Technologies 6050 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Athena Technologies 6050 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Athena Technologies 6050, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Athena Technologies 6050 - die uns die ersten Schritte während der Nutzung von Athena Technologies 6050 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Athena Technologies 6050 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Athena Technologies 6050 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Athena Technologies 6050?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Athena Technologies 6050 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Athena Technologies 6050 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)