    506252-01 Page 1 of 13 Issue 0902 Save these instructions for future reference INST ALLA TION AND MAINTENANCE INSTRUCTIONS (2,4)PCE(13,15) SERIES Electric Cooling Package Unit If this unit is to be installed in a mobile or manufactured home application, the ductwork must be sized to achieve static pressures within the manufacturer ’ s guidelines. ...

  • Allied Air Enterprises 4)PCE(13 - page 2

    Page 2 of 13 506252-01 Issue 0902 INST ALLA TION These instructions, and any instructions p ackaged with mating components and/or accessories, should be carefully read prior to beginning installation. Note p articularly any CAUTIONS or W ARNINGS in these instructions and all labels on the units . These instructions are intended as a general guide o ...

  • Allied Air Enterprises 4)PCE(13 - page 3

    506252-01 Page 3 of 13 Issue 0902 dimension across the unit must be used across the top of the unit. Recommended spreader length: 3 ton and smaller package unit s – 44", 3.5 ton and larger units – 54". Units may also be moved or lifted with a forklif t while still in the factory-supplied packaging. The lengths of the forks of the fork ...

  • Allied Air Enterprises 4)PCE(13 - page 4

    Page 4 of 13 506252-01 Issue 0902 not be sized by matching the dimensions of the duct connections on the unit. Out door ductwork must be insulated and waterproofed. Equipment is shipped for side ductwork connection. The unit can be converted to bottom ductwork connection by removing the duct covers located over the bottom duct openings and placing ...

  • Allied Air Enterprises 4)PCE(13 - page 5

    506252-01 Page 5 of 13 Issue 0902 Power supply to the unit must comply with all applicable codes and the National Electical Code (NEC) or Canadian Electrical Code (CEC). A fused disconnect switch should be field provided for the unit. The switch must be sep arate from all other circuits. If any of the wire supplied with the unit must be replaced, r ...

  • Allied Air Enterprises 4)PCE(13 - page 6

    Page 6 of 13 506252-01 Issue 0902 Compressor Units are shipped with compressor mountings factory- adjusted and ready for operation. Caution: Do not loosen compressor mounting bolts. Heater Kit Accessory (if used) The unit is fully equipped for cooling operation without auxiliary heat. A heater kit accessory may also be used. T o install the heater ...

  • Allied Air Enterprises 4)PCE(13 - page 7

    506252-01 Page 7 of 13 Issue 0902 OPERA TION Sequence of Operation Cooling Upon cooling demand, the thermostat closes circuit R and Y . Closing R and Y closes the unit contactor , starting the compressor and outdoor fan. The thermost at automatically closes R to G circuit which also brings on the indoor blower at the same time. Upon satisfying cool ...

  • Allied Air Enterprises 4)PCE(13 - page 8

    Page 8 of 13 506252-01 Issue 0902 Cooling System Performance For maximum performance of the cooling system, operating temperatures and pressure should be checked. Superheat should be determined at S tandard ARI test conditions of 82°F outdoor and 80°F indoor dry bulb/67°F wet bulb. If superheat measured deviates from values found in T able 4, re ...

  • Allied Air Enterprises 4)PCE(13 - page 9

    506252-01 Page 9 of 13 Issue 0902 Owner Record Model # _________________________________ Serial # _________________________________ Installation Date ___________________________ Installed by: Dealer __________________________________ Address _________________________________ T elephone # ______________________________ License # ____________________ ...

  • Allied Air Enterprises 4)PCE(13 - page 10

    Page 10 of 13 506252-01 Issue 0902 Figure 8 Connection Diagram Single Phase – PSC Motor P/N 48396-001 Unit F actor y Shipped S ettin gs C ooling Input (B L K ) 24 LOW 30 MED 36 HIGH 42 LOW 48 MED 60 HIGH BLOWER SPEED CHART 208/230V -1-60 G W1 C R BLK RED YEL RED CONT ACT OR THERMOST A T L1 T1 T2 L2 C H F CONDENSER F AN MOT OR COMPRESSOR CONT ACT ...

  • Allied Air Enterprises 4)PCE(13 - page 11

    506252-01 Page 11 of 13 Issue 0902 Figure 9 Connection Diagram Single Phase – V ariable S peed Motor P/N 48397-001 CONDENSER F AN MOT OR DIAGNOSTIC MODULE Unit F actor y Shipped Sett ings AD J US T HEA T C OOL 24 NORM B B 30 NORM A A 36 NORM A A 42 NORM C C 48 NORM B B 60 NORM A A BLOWER SPEED CHART NO TE - If any of the original wire is replaced ...

  • Allied Air Enterprises 4)PCE(13 - page 12

    Page 12 of 13 506252-01 Issue 0902 ALLIED AIR ENTERPRISES EQUIPMENT LIMITED W ARRANTY APPLIES IN U.S.A. AND CANADA ONL Y F AILURE TO MAINT AIN YOUR EQUIPMENT WILL VOID THIS W ARRANTY COVERED EQUIPMENT The following Allied Air Enterprises heating and cooling equipment is covered by the Limited W arranty , Condensing Unit s: 2SCU13, 4SCU13, 4SCU14, 4 ...

  • Allied Air Enterprises 4)PCE(13 - page 13

    506252-01 Page 13 of 13 Issue 0902 Allied Air Enterprises Inc. (“Allied Air”) provides its air conditioning and heating product s with a S tandard Limited Parts Wa rranty for five (5) years. This additional 5-Y ear Limited Extended Parts Warranty is in addition to and is intended to supplement Allied Air ’ s S tandard Limited Parts Warranty . ...

Produzent Allied Air Enterprises Kategorie Refrigerator

Dokumente, die wir vom Produzenten des Geräts Allied Air Enterprises 4)PCE(13 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Allied Air Enterprises
- Bedienungsanleitungen 4)PCE(13
- Produktkarten Allied Air Enterprises
- Informationsbroschüren
- oder Energieetiketten Allied Air Enterprises 4)PCE(13
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Allied Air Enterprises 4)PCE(13.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Allied Air Enterprises 4)PCE(13, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Allied Air Enterprises 4)PCE(13. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Allied Air Enterprises 4)PCE(13 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Allied Air Enterprises 4)PCE(13, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Allied Air Enterprises 4)PCE(13 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Allied Air Enterprises 4)PCE(13 verständlich ist.

Eine gänzliche Bedienungsanleitung von Allied Air Enterprises sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Allied Air Enterprises 4)PCE(13 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Allied Air Enterprises 4)PCE(13 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Allied Air Enterprises 4)PCE(13, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Allied Air Enterprises 4)PCE(13 - die uns die ersten Schritte während der Nutzung von Allied Air Enterprises 4)PCE(13 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Allied Air Enterprises 4)PCE(13 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Allied Air Enterprises 4)PCE(13 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Allied Air Enterprises 4)PCE(13?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Allied Air Enterprises 4)PCE(13 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Allied Air Enterprises 4)PCE(13 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)