    / Mar le y Sigma 1 0 0 0/120 0 Cooling T ower / ...

  • SPX Cooling Technologies 1000 - page 2

    2 Y ou’ll enjoy single source r esponsibility and reliability because we design and manufacture virtually all major cooling tower components. All Marley components are designed and selected to be part of an integrated system. For example, the spray pattern from nozzles and the pr essure dr op through drift eliminators both affect a fill’ s hea ...

  • SPX Cooling Technologies 1000 - page 3

    3 / Sigma Adv antag e / •  GuaranteedPerformance. Don’t r ely on outside agencies with limited enforcement powers. W e’ll stand by our responsibility for r eliable thermal performance. We designed it. W e rate it. We guarantee it! •  Exclusive5-Y earMechanicalW arranty . Y our no- cost assurance of trouble-fr ee mech ...

  • SPX Cooling Technologies 1000 - page 4

    4 / Constr uction and Components / Fill/Louvers/Drift Eliminators Marley high-performance film fill is the heart of every Sigma tower . A repeating chevr on pattern provides the wetted surface and air turbulence necessary for proper heat transfer , while minimizing resistance to airflow so you’ll save on fan power . Molded protrusions on each ...

  • SPX Cooling Technologies 1000 - page 5

    5 fans, used on larger models, include hollow GRE (glass- reinfor ced epoxy) blades and epoxy-coated cast iron hubs. Blades on both fan types are adjustable in pitch, so you can take full advantage of rated horsepower or adjust the pitch to compensate for unusual job site restrictions. The true airfoil blades, designed specifically for cooling tow ...

  • SPX Cooling Technologies 1000 - page 6

    6 W ater Distribution System The gravity-flow water distribution system designed into the Sigma tower essentially reduces pump head to its most basic component – static lift – saving you money on pump power . Y ou won’t have to for ce water through internal piping and pressur e spray nozzles, as you would in a counterflow tower . W arm wate ...

  • SPX Cooling Technologies 1000 - page 7

    7 The 4" x" 4 tower diagonals carry loads to heavy- duty hot-dip galvanized steel anchor plates or hot-dip galvanized anchor weldments. The system of longitudinal and transverse diagonal bracing provides stability in a true tension-compression design. the mechanical equipment. The taller fan cylinders used on Series 1200 models effectivel ...

  • SPX Cooling Technologies 1000 - page 8

    8 / A v ailable Options / Accessory Description and Remarks Accessory Description and Remarks Plywood Cold W ater Collection Basin Pressur e-treated Douglas fir plywood collection basin for towers located above grade. See page 11. Bottom-Outlet Sump Square-plan galvanized steel sump with bottom outlet. Outlet connection is a hole and bolt circle c ...

  • SPX Cooling Technologies 1000 - page 9

    9 Cell Partition Options Every Sigma tower includes plenum chamber partitions and hot water distribution basin partitions between adjacent cells. Plenum partitions ensure consistent thermal performance as you shut off one fan at a time. They keep air from entering an operating cell thr ough an adjacent idle fan, maintaining efficient thermal perfo ...

  • SPX Cooling Technologies 1000 - page 10

    10 Fire Pr otection Options The PVC fill, louvers and drift eliminators used on Sigma towers are fir e-retar dant, having flame spread ratings less than 25 per ASTM E-84. Standard fan decking material is pressur e-treated fir plywood which ignites poorly and burns slowly . For these reasons, governing agencies (such as Factory Mutual) may not r ...

  • SPX Cooling Technologies 1000 - page 11

    11 Cold W ater Collection Basins If you plan to locate your tower above grade, a treated Douglas fir Marley cold water collection basin is available, complete with the necessary operating accessories. The basin floor is exterior grade, pressur e-treated fir plywood, supported on joists. Basin sides are plywood, machined to fit the basin floor ...

  • SPX Cooling Technologies 1000 - page 12

    / Additional Services / SPX Cooling T echnologies is dedicated to satisfying the needs of our customers—needs which begin far in advance of the actual purchase of a new Marley cooling tower , and vary over the operating lifetime of the project. Here is a partial listing of the additional services offer ed by SPX Cooling T echnologies to help you ...

Produzent SPX Cooling Technologies Kategorie Ventilation Hood

Dokumente, die wir vom Produzenten des Geräts SPX Cooling Technologies 1000 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen SPX Cooling Technologies
- Bedienungsanleitungen 1000
- Produktkarten SPX Cooling Technologies
- Informationsbroschüren
- oder Energieetiketten SPX Cooling Technologies 1000
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung SPX Cooling Technologies 1000.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen SPX Cooling Technologies 1000, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen SPX Cooling Technologies 1000. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts SPX Cooling Technologies 1000 ansehen.

Die komplette Bedienungsanleitung des Geräts SPX Cooling Technologies 1000, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von SPX Cooling Technologies 1000 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von SPX Cooling Technologies 1000 verständlich ist.

Eine gänzliche Bedienungsanleitung von SPX Cooling Technologies sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von SPX Cooling Technologies 1000 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von SPX Cooling Technologies 1000 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich SPX Cooling Technologies 1000, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts SPX Cooling Technologies 1000 - die uns die ersten Schritte während der Nutzung von SPX Cooling Technologies 1000 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit SPX Cooling Technologies 1000 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von SPX Cooling Technologies 1000 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich SPX Cooling Technologies 1000?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit SPX Cooling Technologies 1000 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit SPX Cooling Technologies 1000 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)