Bedienungsanleitung APC SURT10000RMXLT-2TF5

20 Seiten Betrifft nicht
Download

Zur Seite of 20

Summary
  • APC SURT10000RMXLT-2TF5 - page 1

    990-1216B 02/2004 User Manual English APC Smart APC Smart APC Smart APC Smart- - - -UP S UPS UPS UPS ® ® ® ® RT RT RT RT 7500/10000 VA 200 7500/10000 VA 200 7500/10000 VA 200 7500/10000 VA 200- - - - 240 VAC 6U 240 VAC 6U 240 VAC 6U 240 VAC 6U Tower/Rack Mount Tower/Rack Mount Tower/Rack Mount Tower/Rack Mount Uninterruptible Power Supply Unint ...

  • APC SURT10000RMXLT-2TF5 - page 2

    ...

  • APC SURT10000RMXLT-2TF5 - page 3

    1 Introduction The APC Smart-UPS RT is a high-performance, uninterruptible power system (UPS), designed to prevent blackouts, brownouts, sags and surges from reaching your com puters, servers, and other sensitive electronic equip ment. 1: I NST ALLA TION Attention: Re ad the safety i nformation sheet be fore installation. Unpacking Inspect the UPS ...

  • APC SURT10000RMXLT-2TF5 - page 4

    2 Hardwiring Attention: Wiring must be performed by a qualified electrician. 1. Install a utility circuit breaker in accordance with local electrical codes (see tables below) for input wiring only. 2. Switch the UPS input ci rcuit breaker (see A ) and utility circuit breakers OFF. 3. Remove the access panel (see B ). 4. Remove circular knocko uts. ...

  • APC SURT10000RMXLT-2TF5 - page 5

    3 7. XLI model only: For three-phase input, set the Input Phase Selector switch (see C ) to ‘3’. For single-phase input, leave switch in default position of ‘1’. 8. Switch the circuit breakers ON. 9. Check line voltages. 10. Replace the access panel. XLT/XLJ/XLTW M ODELS XLI M ODEL L1 L2 L1A L2A O UTPUT I NPUT O UTPUT I NPUT L1 L2 L3 N C B ...

  • APC SURT10000RMXLT-2TF5 - page 6

    4 Installing and Connecting the Batteries and Attaching the Front Bezel       ...

  • APC SURT10000RMXLT-2TF5 - page 7

    5 C ONNECTING P OWER AND E QUIP MENT TO THE UPS 1. Hardwire the UPS (see Hardwiring ). 2. Connect equi pment to the UPS (cables not included for X LT/XLJ/XLTW m odels). 3. Turn on all connected equipm ent. To use the UPS as a m aster on/off switch, be sure that all connected equipm ent is switched ON. 4. Press the button on the front panel to power ...

  • APC SURT10000RMXLT-2TF5 - page 8

    6 B ASIC C ONNECTORS Serial Port Power management software and interface kits can be used with the UPS. Use only inter face kits suppli ed or approved b y APC. Ethernet Port Connect the UPS to the network . (Located on Web/SNMP card.) EPO Terminal The optional Emergency Power Off (EPO) feature allows connected loads to be immediately de-en ergized ...

  • APC SURT10000RMXLT-2TF5 - page 9

    7 2: O PERA TION F RONT D ISPLAY P ANEL Indicator Description Online The UPS is drawing utility power and performin g double conversion to sup ply power to connected equipm ent (see Troubl eshootin g ). On Battery The UPS is supplying battery powe r to the connected equipment. Bypass The UPS is in bypass mode, sending utility power directly to conn ...

  • APC SURT10000RMXLT-2TF5 - page 10

    8 Feature Function Normal /Bypass Manually switch connected eq uipment to bypass mode, so that utility power is sent directly to connected equipment. Battery op eration is not available while the UPS is in bypass mode. (See Troubleshooting. ) Cold Start This is not a normal condition. Supply immediate battery power to the UPS and connected equipm e ...

  • APC SURT10000RMXLT-2TF5 - page 11

    9 3: U SER C ONFIGURABLE I TEMS N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HUTE SOFTWARE , W EB /SNMP CA RD , OPTIONAL S MA R T S LOT ACCESSORY CARDS OR T ER MINAL M ODE . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Automatic Self-Test Every 14 days (336 hours) Every 7 d ays (168 hours), Every 14 days (336 hours), ...

  • APC SURT10000RMXLT-2TF5 - page 12

    10 N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HUTE SOFTWARE , W EB /SNMP CA RD , OPTIONAL S MA R T S LOT ACCESSORY CARDS OR T ER MINAL M ODE . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION High Bypass Point +10% of output voltage setting +5%, +10%, +15%, +20% Maximum voltage that the UPS will pass to connected equipm ...

  • APC SURT10000RMXLT-2TF5 - page 13

    11 EPO (Emergency Power Off) Option The output power can be disabled i n an emergency by closing a s witch connected to the EPO. Adhere to national and loca l electrical codes when wiring. The switch should be connected in a normally open switch contact. External voltage is not required; the switch is driven by 12V internal supply. In closed condit ...

  • APC SURT10000RMXLT-2TF5 - page 14

    12 Terminal Mode to Configure UPS Parameters Terminal Mode is a menu driven interface that enables en hanced configuration of the UPS. Connect the serial cable to the serial port on the back of t he UPS. When using Po werChute ® Network Shut down software: 1. Open a t erminal pro gram. Exam ple: HyperT erminal • From the Desk top, go to Start =& ...

  • APC SURT10000RMXLT-2TF5 - page 15

    13 4: S TOR AG E , M AINTE NANCE , AND T RANSPORTING Storage Store the UP S covered a nd positi oned as for pro per functioni ng, in a cool , dry locatio n, with the batteries fully charged. (Bat teries must be c harged every six mont hs.) Store at: 0 -50,000 ft (0 - 15,000 m) 5 ° -113 ° F ( -15 - 45 ° C) Replacing the Battery Module(s) This UPS ...

  • APC SURT10000RMXLT-2TF5 - page 16

    14 5: T ROUBLESHOOTING Use the table below to solve minor installation and operation prob lems. Refer to the APC web site, www.apc.com , for assistance with complex UPS problems. P ROBLEM AND P OSSIBLE C AUS E S OLUTION UPS WILL NOT TURN ON Batteries are not connected properly. Check that the battery connectors are fully engage d. button not pushed ...

  • APC SURT10000RMXLT-2TF5 - page 17

    15 P ROBLEM AND P OSSIBLE C AUS E S OLUTION BYPASS LED ILLUMINATES The bypass switch has been turned on manually or through an accessory. If bypass is the chosen mode of ope ration, ignore the illuminated LED. If bypass is not the chosen mode of operation move the bypass switch on the back of the UPS, to the normal position. FAULT AND OVERLOAD LED ...

  • APC SURT10000RMXLT-2TF5 - page 18

    16 Service If the UPS requires service do not return it to the dealer. Instead, follow these steps: 1. Review t he problem s discussed in the Troubl eshooting section of t his manual to eliminate common pr oblems. 2. If the pr oblem persists, contact APC C ustomer Se rvice through t he APC we b site, www.apc.com /support .  Note the m odel numbe ...

  • APC SURT10000RMXLT-2TF5 - page 19

    17 6: R EGULA T OR Y AND W ARRANTY I NFORMA TION Regulatory Agency Approvals and Radio Frequency Warnings 200, 208, 220, 230, 240 V MODELS This is a Class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take corrective actions. This equipment has been tested and found to comp ...

  • APC SURT10000RMXLT-2TF5 - page 20

    18 Declaration of Conformity ...

Produzent APC Kategorie Uninterruptible power supply (

Dokumente, die wir vom Produzenten des Geräts APC SURT10000RMXLT-2TF5 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen APC
- Bedienungsanleitungen SURT10000RMXLT-2TF5
- Produktkarten APC
- Informationsbroschüren
- oder Energieetiketten APC SURT10000RMXLT-2TF5
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung APC SURT10000RMXLT-2TF5.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen APC SURT10000RMXLT-2TF5, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen APC SURT10000RMXLT-2TF5. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts APC SURT10000RMXLT-2TF5 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts APC SURT10000RMXLT-2TF5, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von APC SURT10000RMXLT-2TF5 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von APC SURT10000RMXLT-2TF5 verständlich ist.

Eine gänzliche Bedienungsanleitung von APC sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von APC SURT10000RMXLT-2TF5 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von APC SURT10000RMXLT-2TF5 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich APC SURT10000RMXLT-2TF5, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts APC SURT10000RMXLT-2TF5 - die uns die ersten Schritte während der Nutzung von APC SURT10000RMXLT-2TF5 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit APC SURT10000RMXLT-2TF5 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von APC SURT10000RMXLT-2TF5 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich APC SURT10000RMXLT-2TF5?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit APC SURT10000RMXLT-2TF5 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit APC SURT10000RMXLT-2TF5 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)