    PRIMERGY RX2 00 S6 System configurator and order-information guid e Contents 4x or 6x 2.5" Hot-plu g HDD or SSD 8x 2.5" Hot-plug HDD or SDD Instruc tions Configuration diagram Configurator 0 System softw are I Basic unit II Processor III Memory IV Graphics V Accessible drives G-VI Drive Bay for 6x 2. 5" HD Basic Unit G-VII Modular Ra ...

  • Fujitsu PRIMERGY RX200 S6 - page 2

    System configurator and order-infor mation guide PRIMERGY RX 200 S6 Status 2011-1 0-30 Instructions This document c ontains basic product and configuration information that will enable you to configure your system via PC-/SystemArchit ect. Only these tools will ensure a fast and prope r configuration of your PRIM ERGY server or you r complete PRIME ...

  • Fujitsu PRIMERGY RX200 S6 - page 3

    System configurator and order-infor mation guide PRIMERGY RX 200 S6 Status 2011-1 0-30 Configuration diagra m PRIMERGY RX200 S6 Sy st em unit (I) board front side Memory CPU1 right side (Channe l A + B + C) A cc essible drives (V) Bank 1 (3 Modules) Bay for 5,25"x 0,5" SATA-DVD Bank 2 (3 Modules) Only with option 6x 2.5" HD Memory CP ...

  • Fujitsu PRIMERGY RX200 S6 - page 4

    PRIMERGY - Softw are Co nfigurato rs and Release Lists Start PRIMERGY RX 200 S6 PRIMERGY RX200 S6 S tatus 201 1-10-30 SW Configurator 32 bit with OEM -Software without OEM-Softw are for PRIMERGY Server for PRIMERGY Server OEM- SW is bound to HW and VMware-Software is not all owed to be ord ered - Virtual Center Mana geme nt Server for any server re ...

  • Fujitsu PRIMERGY RX200 S6 - page 5

    PRIMERGY-Softwa re Configur ators and Release Lists Start PRIME RGY RX2 00S6 PRIMERGY RX 200 S6 Status 2011-1 0-30 SW Con figurator 64 bit (EM64T / IA6 4) w ith OEM-Softw are w ithout OEM-Softw are for PRIME RGY Server for PRIME RGY Server OEM - SW is bou n d to HW and For all SW products plea se refer to the correspon din g is no t all ow ed to be ...

  • Fujitsu PRIMERGY RX200 S6 - page 6

    System c onfigurator and order-inf ormation guide Start PRIMERGY RX200 S6 PRIMERGY RX200 S6 Status 2011-10-30 Section I Basic u n it System u nit con sistin g of: * 1U Hou sin g in clu din g - power cord rack 4m len gth (PSU has to b e config ured min 1x) * Fan s - Redun dant a nd ho t plug system fans ( 6x ) * Drive s / Bays - 6x 2. 5" SA S / ...

  • Fujitsu PRIMERGY RX200 S6 - page 7

    System c onfigurator and order-inf ormation guide A PRIMERGY RX200 S6 Status 2011-10-30 In terfac es at th e re ar: * 1x RS-232-C (seria l, 9 pi ns) (usable for BMC or OS or sha red) * 1x VGA (15 pin s): If Front-VGA is used , then Rear-VGA is disabl ed * 3x USB 2.0 (UHCI ) with 4 80MBit/s, no USB wake up * 2x LAN RJ45, 1x Service-LAN RJ45 In terfa ...

  • Fujitsu PRIMERGY RX200 S6 - page 8

    System c onfigurator and order-inf ormation guide B PRIMERGY RX200 S6 Status 2011-10-30 Rack v ersi on for 19'' rac ks w ith NO PSU incl ude d in Base Un it No Rack-mo un tin g kit i ncl ude d For an orderable basic u nit o ne CPU = first CPU, one memory = first m emory one PSU = first PSU as well as on e of tw o possible rack-m oun t ki ...

  • Fujitsu PRIMERGY RX200 S6 - page 9

    System c onfigurator and order-inf ormation guide C PRIMERGY RX200 S6 Status 2011-10-30 S26361 -F2735 -E101 S26361 -F2735 -E110 S26361 -F2735 -E111 S26361 -F2735 -E140 RMK-F1_1-2U Server RMK-P_1-2U Server No Rackmount-Ki t opti on RMK-F1_DI_ CMA (Drop-in) telescopic rai l, full extraction, telescopic rai l, parti al extractio n Only for loose de li ...

  • Fujitsu PRIMERGY RX200 S6 - page 10

    System c onfigurator and order-inf ormation guide D PRIMERGY RX200 S6 Status 2011-10-30 Section II Processor There a re 2 pro cessor sockets available. The first socke t is alway s equip ped wit h the firs t CPU which can be selected via config urator It i s also possible to up grade a dua l-processor system later on with a seco nd CPU Two process ...

  • Fujitsu PRIMERGY RX200 S6 - page 11

    System c onfigurator and order-inf ormation guide E PRIMERGY RX200 S6 Status 2011-10-30 Section III Memory - There a re 6 me mory slots for m ax. 9 6GB registere d (reg) DDR3 RA M per CPU av aila ble w ith 1 6GB RDIMMs or max. 12GB u nbu ffere d (ub ) DDR3 RA M per CPU av aila ble w ith 2GB UDIMMs => max. 1 92GB registe red or 24 GB un bu ffered ...

  • Fujitsu PRIMERGY RX200 S6 - page 12

    System c onfigurator and order-inf ormation guide F PRIMERGY RX200 S6 Status 2011-10-30 For a des cription of me mory con figu ration s refer to section "Mem ory Configu ration s" Minimum one memory modu le or memory order code per CPU = first memory Registered (reg) RDIMMs (1.5V) Note 1.) For "Independen t Channel M ode" usa ge ...

  • Fujitsu PRIMERGY RX200 S6 - page 13

    System c onfigurator and order-inf ormation guide F1 F2 PRIMERGY RX200 S6 Status 2011-10-30 S26361 -F3284 -E1 S26361 -F3284 -E2 Spare Ch an ne l Mode I n stallati on Performan ce Mode In sta llation W ith thi s order code a BI OS setup W ith thi s order code BIOS setu p for spare mod e is factory preinsta lled is defaul t for h ighest p erformance ...

  • Fujitsu PRIMERGY RX200 S6 - page 14

    System c onfigurator and order-inf ormation guide G1 G2 PRIMERGY RX200 S6 Status 2011-10-30 S26361 -F3284 -E3 Mirrored Cha nn el Mode In sta llation W ith thi s order code a BI OS setup for Mirrored Channe l Mode i s factory pre install ed The two i denti cal memory modu les of foll owing order code s are alwa ys equipped in one mem ory bank to us ...

  • Fujitsu PRIMERGY RX200 S6 - page 15

    System c onfigurator and order-inf ormation guide PRIMERGY RX200 S6 Status 2011-10-30 Section IV Graphic s Graphics Control ler in tegrate d in i RMC S2 (integ rated Re mote Manag ement Con troller): 1600x12 00x16bp p 60Hz , 128 0x1024x16b pp 60 Hz, 10 24x768x32 bpp 7 5Hz, 80 0x600x32b pp 85 Hz, 64 0x480x32b pp 85 Hz (1280x10 24x24bp p 60Hz only po ...

  • Fujitsu PRIMERGY RX200 S6 - page 16

    System co nfigurato r and orde r-informa tion guide PRIMERGY RX 200 S6 Stat us 2011 -10-30 Memory Configuration PRIMERGY RX200 S6 Each CPU of fers 6 Slots fo r DDR3 Memo ry Modules organised in 2 Ba nks and 3 Channe ls. If you need m ore than 6 Slots you ha ve to configu re the 2n d CPU. Depend ing on t he am oun t of m em ory configured you can de ...

  • Fujitsu PRIMERGY RX200 S6 - page 17

    System co nfigurato r and orde r-informa tion guide PRIMERGY RX 200 S6 Stat us 2011 -10-30 Used CPU Dual-Core CPU with max. 800MHz DDR3 spee d (4.8GT/s) Xeon E5503 2C/2.00 GHz/2M/4,80GT/s (80W ) Quad-Core CPU`s with max. 800MHz DDR3 spee d (4.8GT/s) Xeon E5506 4C/2.13 GHz/4M/4,8GT/s (80W ) Xeon E5507 4C/2.26 GHz/4M/4,8GT/s (80W ) Turbo Qu ad-Core C ...

  • Fujitsu PRIMERGY RX200 S6 - page 18

    System co nfigurato r and orde r-informa tion guide PRIMERGY RX 200 S6 Stat us 2011 -10-30 1. Independent Channel Mode required required if 2 nd CPU is config ured Bank I Data Data Data Data Data Data optiona l, sam e type in Ba nk p er CPU (black so ckets) Bank II Data Data Data Data Data Data optiona l, any type (blue sock ets) ------ -- not used ...

  • Fujitsu PRIMERGY RX200 S6 - page 19

    System c onfigurator and order-inf ormation guide I PRIMERGY RX200 S6 Status 2011-10-30 Section V Accessible drives Setup RX200 S6 by ServerStart is supporte d with foll owing confi gurati ons: no Flopp y, no DVD, n o CD: remote install atio n only ( PXE service & DHCP server requi red) built in CD/DVD or USB CD/DVD, n o Flopp y disk drive: UNC ...

  • Fujitsu PRIMERGY RX200 S6 - page 20

    System configurator and order-infor mation guide J PRIMERGY RX 200 S6 Status 2011-1 0-30 Section G-VI Drive Bay for 6x / 8x 2.5" HD Ba sic Unit Base Unit S2636 1-K134 2-V10 1 Drive Bay w ith u p to 6x 2.5" HDDs plu s on e ba y for DVD On ly 4 HDD Po rts are conn ected to a RAID Con t roll er. In ord er to conn ect HD5 an d HD 6, S263 61-F ...

  • Fujitsu PRIMERGY RX200 S6 - page 21

    System configurator and order-infor mation guide J1 PRIMERGY RX 200 S6 Status 2011-1 0-30 J2 Section G-VIII 4x / 6x / 8x 2 .5" SA S / SAT A Ha rd disk drive s Section G- IX 4x 2.5" S ATA Ha rd disk drives For basic u n its V1x x u p to 6x SA TA / SAS 2.5" h ard di sks plus ODD can be con figure d. W ith on boa rd SATA con troll er Fo ...

  • Fujitsu PRIMERGY RX200 S6 - page 22

    System configurator and order-infor mation guide L PRIMERGY RX 200 S6 Status 2011-1 0-30 Section X External SA S Dis k Array , SAS back up drives or SCSI periphe ral device s External 8-po rt SAS-co ntroller for external SA S Disk Array S263 61-F35 93-E2 01 RAID Ctrl SAS 6G 8po rt extern al LSI Me gaRAID SAS 928 0-8e 512M B Ca che wi th EC C RAID 0 ...

  • Fujitsu PRIMERGY RX200 S6 - page 23

    System configurator and order-infor mation guide M PRIMERGY RX 200 S6 Status 2011-1 0-30 Section XI Fibre Chan nel Fibre Chan nel Controller for externa l storage sy stems S263 61-F33 06-E2 01 S263 61-F33 06-E2 02 4GBi t/s FC Con trolle r 4GBi t/s FC Con trolle r Emul ex Emul ex LPe1 150, Lo w Profile bracket LPe1100 2, Low Profil e bracket 1 cha n ...

  • Fujitsu PRIMERGY RX200 S6 - page 24

    System configurator an d order-information gu ide N PRIMERGY RX 200 S6 Statu s 2011-10-30 Section XII Communicat ion / Network 2x 1GBit on-b oard LAN Cont roller Teaming: Failov er, Load Balancing Gigabit Ethernet Control ler on-board The Intel LAN Controllers 100 0TX and 1000SX Dual Port GBit LA N controller can be used w ith the on-board controll ...

  • Fujitsu PRIMERGY RX200 S6 - page 25

    System configurator an d order-information gu ide N1 PRIMERGY RX 200 S6 Statu s 2011-10-30 F) InfiniBan d HCA's S26361-F4475-E102 S26361-F4475-L102 IB HCA 40Gb 1 port QDR for loo se deli very IB HCA 1x 40Gb PCIe 2.0 (5,0GT/s) Low Profil e PCIe form f actor with exchangeabl e PCIe x8, l ow profile Full Height (FH) or Low Profil e (LP) bracket e ...

  • Fujitsu PRIMERGY RX200 S6 - page 26

    System configurator and order-infor mation guide O PRIMERGY RX 200 S6 Status 2011-1 0-30 Section XIII System Mana gemen t Products (Re moteView) S263 61-F17 90-E2 41 iRM C S2 (in t egrated Remote M an agemen t Con trol ler) on bo ard server managemen t iRMC S2 adva nced pack control le r with de dicate d 10/10 0 Service L AN-port an d i n tegrated ...

  • Fujitsu PRIMERGY RX200 S6 - page 27

    System configurator and order-infor mation guide P PRIMERGY RX 200 S6 Status 2011-1 0-30 Section XVI Energy Star S263 61-F33 01-E4 01 RX200 S6 E-Star Fa m1 Limits con figu ration in accorda n ce wi th E ne rgy Star requ iremen ts max. 1x per sy stem The following order compo nents ou t of the spec ific sections are allowed together with RX200 S6 E- ...

  • Fujitsu PRIMERGY RX200 S6 - page 28

    System configurator and order-infor mation guide PRIMERGY RX 200 S6 Status 2011-1 0-30 Change Report Date Order number Changes 2011-1 0-30 S26361 -F4541-Ex00 new SAS SSD with 100 , 200, 400 GB add ed - as soon a s available 2011-1 0-01 S26361 -F3601-E25 0 new BC SATA HD - now available 2011-1 0-01 S26361 -F3298-E64 64 GB SSD - no longer availab le ...

Produzent Fujitsu Kategorie Server

Dokumente, die wir vom Produzenten des Geräts Fujitsu PRIMERGY RX200 S6 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Fujitsu
- Bedienungsanleitungen PRIMERGY RX200 S6
- Produktkarten Fujitsu
- Informationsbroschüren
- oder Energieetiketten Fujitsu PRIMERGY RX200 S6
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Fujitsu PRIMERGY RX200 S6.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Fujitsu PRIMERGY RX200 S6, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Fujitsu PRIMERGY RX200 S6. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Fujitsu PRIMERGY RX200 S6 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Fujitsu PRIMERGY RX200 S6, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Fujitsu PRIMERGY RX200 S6 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Fujitsu PRIMERGY RX200 S6 verständlich ist.

Eine gänzliche Bedienungsanleitung von Fujitsu sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Fujitsu PRIMERGY RX200 S6 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Fujitsu PRIMERGY RX200 S6 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Fujitsu PRIMERGY RX200 S6, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Fujitsu PRIMERGY RX200 S6 - die uns die ersten Schritte während der Nutzung von Fujitsu PRIMERGY RX200 S6 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Fujitsu PRIMERGY RX200 S6 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Fujitsu PRIMERGY RX200 S6 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Fujitsu PRIMERGY RX200 S6?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Fujitsu PRIMERGY RX200 S6 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Fujitsu PRIMERGY RX200 S6 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)