Bedienungsanleitung Amcor PVMB 12KEH-410

15 Seiten Betrifft nicht
Download

Zur Seite of 15

Summary
  • Amcor PVMB 12KEH-410 - page 1

    R E N O I T I D N O C R I A E L B A T R O P GB Portable air conditioner PVMB 9KEH-410 12KEH-410 15KEH-410 ...

  • Amcor PVMB 12KEH-410 - page 2

    2 SAFET Y INSTRUC TIONS Thank you for choosing this innovative Amcor air conditioner . W e suggest that you keep this manual in a safe place for future reference. It describes the many benefits and advanced features this unique product has to offer . Before you use your new air conditioner you should carefully read these instructions to maximise th ...

  • Amcor PVMB 12KEH-410 - page 3

    3 • Never operate this appliance if it has a damaged cord or plug. Do not lead the cord over sharp edges. • A damaged supply cord should be replaced by the manufacturer , its service agent or a qualified person in order to avoid a hazard. • Any service other than regular cleaning or filter replacement should be performed • Keep a minimal 0. ...

  • Amcor PVMB 12KEH-410 - page 4

    4 Slide bar connector Active carbon filter T elescopic slide bar Exhaust hose W ater container Remote control with LCD PA R T S 10 6 5 8 7 9 3 1. Air outlet 2. Control panel 3. C arrying handle 4. Caster wheels 5. Grill housing 6. Upper air inlet 7. Exhaust air outlet 8. Lower air inlet 9. Cable storage 10. Drainage point with water stopper GB 1 2 ...

  • Amcor PVMB 12KEH-410 - page 5

    5 GB INS T A LL A TI ON WARNING! Before using the air conditioner it should be left in an upright position for at least 2 hours. This unit can easily be moved from one room to another . In doing so keep this in mind: – Ensure that the unit is positioned upright, on a level surface and 50 cm away from any obstacles. – T o place the loose filters ...

  • Amcor PVMB 12KEH-410 - page 6

    6 GB CON TROL P ANEL A ND DISPLA Y F an speed Clock/timer T emperature Heating Cooling Sleep mode Timer settings Sensor remote control Down Sleep mode Swing Mode Up F an ON/OFF Timer ...

  • Amcor PVMB 12KEH-410 - page 7

    7 ON/OFF Press to switch the unit on, or to switch off. A buzzer will beep, and the LCD will display 12:00 o’clock as default. Setting the clock Press the -button for 3 seconds to set the clock. The 2 left digits of the 4 digits on the LCD-display will flash. Press or to adjust the hour . Press momentarily , the 2 right digits of the 4 digits wil ...

  • Amcor PVMB 12KEH-410 - page 8

    8 Programming the timer for ON - when the unit is OFF. • Perform the standard steps as described above. The linear time scale will be on between the ON programmed times until 24:00. The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes until it reaches the ON timer time, then the black segments in t ...

  • Amcor PVMB 12KEH-410 - page 9

    9 Air flow On the moment the air conditioner is connected to the mains, the louvres open and close and stay closed. • When the ON-button is pressed, the louvres open to maximum and return to an angle of 75° above the upper plane of the louvres housing. • Press the -button, the louvres will swing continuously up and down between 30° and 80° a ...

  • Amcor PVMB 12KEH-410 - page 10

    10 The unit responds to all signals that are sent by the remote control. There will be a beep sound from the unit after receiving the signal. The operation of the unit by remote control, is almost identical to the operation by the control panel. The only exception is the clock function. Instead of the -button for setting the actual time and for pro ...

  • Amcor PVMB 12KEH-410 - page 11

    11 This air conditioner is equipped with two filter sets: 1. A multi layer filter in the upper air inlet, to clean the circulated room air , which includes a. A screen filter , to remove dust particles. b. An active carbon filter , to remove odours. 2. A screen filter in the lower air inlet, to remove dust particles. NOTE! The active carbon filter ...

  • Amcor PVMB 12KEH-410 - page 12

    12 EMP T YING THE INTERNAL W A TER CO NT AINER Under high humidity conditions it may be necessary to empty the internal water container . When the internal water container is full the backlight on the LCD-display flashes. The unit will switch off automatically . T o empty the water container do the following: • Switch off the unit and remove the ...

  • Amcor PVMB 12KEH-410 - page 13

    13 Never try to repair or dismantle the air condition yourself. Incompetent repairs result in loss of warranty and can endanger the user and the property . Problem Cause Solution The air conditioner does not function. No power supply . Connect to a functioning outlet and switch on. Is the LCD light fl ashing. Empty the internal water container . T ...

  • Amcor PVMB 12KEH-410 - page 14

    14 Reminder: W aste electrical products must not be disposed of with household waste. This product should be taken to your local recycling centre for safe treatment. TEC HN ICAL DA T A Model PVMB 9KEH-410 PVMB 12KEH-410 PVMB 15KEH-410 Cooling capacity measured conform EN 14511 BTU/h 7500 9400 11300 kW 2.2 2.75 3.3 Power consumptio n kW 0.8 1.0 1.5 ...

  • Amcor PVMB 12KEH-410 - page 15

    China Shan Xia Industrial Development Zone, Heng Li T own, Dongguan City , Guangdong Province, China Plant One - Amcor (China) Ltd T el: +86 769 8372 1090 F ax: +86 769 8372 1790 Email: amcorcn@amcorgroup.com Plant T wo - Amcor Appliances Ltd T el: +86 769 8372 1970 F ax: +86 769 8372 1790 Email: amcorappl@amcorgroup.com - GB B M V P 2xxxx 1 3 1 9 ...

Produzent Amcor Kategorie Air-conditioning

Dokumente, die wir vom Produzenten des Geräts Amcor PVMB 12KEH-410 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Amcor
- Bedienungsanleitungen PVMB 12KEH-410
- Produktkarten Amcor
- Informationsbroschüren
- oder Energieetiketten Amcor PVMB 12KEH-410
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Amcor PVMB 12KEH-410.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Amcor PVMB 12KEH-410, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Amcor PVMB 12KEH-410. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Amcor PVMB 12KEH-410 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Amcor PVMB 12KEH-410, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Amcor PVMB 12KEH-410 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Amcor PVMB 12KEH-410 verständlich ist.

Eine gänzliche Bedienungsanleitung von Amcor sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Amcor PVMB 12KEH-410 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Amcor PVMB 12KEH-410 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Amcor PVMB 12KEH-410, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Amcor PVMB 12KEH-410 - die uns die ersten Schritte während der Nutzung von Amcor PVMB 12KEH-410 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Amcor PVMB 12KEH-410 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Amcor PVMB 12KEH-410 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Amcor PVMB 12KEH-410?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Amcor PVMB 12KEH-410 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Amcor PVMB 12KEH-410 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen