    Report No.1 16-L-49-5 I N S T A L L A T I O N A N D O P E R A T I O N I N S T R U C T I O N S Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. WHA T TO DO IF YOU SMELL GAS: • Do not light any appliance. • Do not touch any electrical switch; do not use any phone in your building. ...

  • Milwaukee LSVFSD-LP - page 2

    2 IM PO R T A N T SA FET Y AN D W AR NIN G IN FO RM A TI O N REA D T HIS MA NUA L I N I TS ENT IRE TY AND UN DER - ST AND THE SE R ULE S T O F OLL OW FOR SA FET Y . W ARNINGS If t he in for mat ion in t hi s ma nua l i s n ot f ol- lo we d exa ctl y , a fir e or exp los ion ma y re su lt ca us in g p rop ert y d ama ge , pe rs ona l i nju r y or l ...

  • Milwaukee LSVFSD-LP - page 3

    3 NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. These Gas Log Appliances incorporate unitized ceramic fiber logs which provides some glow realistically when the appliance is operating. The gas log sets covered in this document are heater rated units. These units are equipped with a millivolt gas valve. The control knob is set to the desired ...

  • Milwaukee LSVFSD-LP - page 4

    4 Adhere to all local codes or in their absence the latest edition of The National Fuel Gas Code ANSI Z223.1 or NFP A 54-latest edition which can be obtained from The American National Standards Institute, Inc. (1430 Broadway , New Y ork, NY , 10018) or National Fire Protection Association, Inc. (Batterymarch Park, Quincy , MA, 02269). State or loc ...

  • Milwaukee LSVFSD-LP - page 5

    5 This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and v entilati on air . The heat er may be located in u nusuall y tight c onstruc - tion provide d the space is unconfined, or if confined, is provide d with two permanent openings communicating directly ...

  • Milwaukee LSVFSD-LP - page 6

    6 Not e: Illustrations shown in this manual reflect “typical” installations with nominal dimensions and are for reference only . Actual installations may vary due to individual design preferences. However , always main- tain minimum clearances to combustible materials and do not violate any specific installation requirements. Refer to Figures ...

  • Milwaukee LSVFSD-LP - page 7

    NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. 7 Figure 3 Step 2. Ceiling Clearance: The ceiling must be at least 42" from the top of the appliance opening ( Figure 2 ) . Step 3. Noncombu stible materials (minimum requiremen ts): T o install the appl ianc e wit hout wood mant els, she lves or ot her combus tibl e pro jec- tions directly a ...

  • Milwaukee LSVFSD-LP - page 8

    8 NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. Any outside air ducts and/or ash dumps in the fireplace shall be perma- nently closed at time of appliance installation. A qualified gas appliance installer must install this dual-listed appli - ance. Check gas type: The gas supply must be the same as stated on the applia nce’ s rating pl at ...

  • Milwaukee LSVFSD-LP - page 9

    NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. 9 The appliance gas inlet connection is 3/8" NPT at the regulator/valve, located on the left side facing the appliance. If a right side connection is requ ired, the co nnect ion pi pe may be piped under the rea r of th e appl iance to end at the left hand side for connection to the inlet. Whe ...

  • Milwaukee LSVFSD-LP - page 10

    10 NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. LOG PLACEMENT INSTRUCTIONS 1. Place rear ember bed as shown in Figure 11 . Figure 11 - Install Rear Ember Bed 2. Place rear log onto the two rear grate locating pins as shown in Figure 12 (the locating pins are outlined in Figure 11 ). 3. Place middle log onto left middle grate locating pin and ...

  • Milwaukee LSVFSD-LP - page 11

    11 NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. 7. Place the right top log onto rear log locating pin and the right front log locating pin as shown in Figure 17 . Right T op Log Locating Pins 8. Pla ce Left T op T w ig (24" and 30" mo dels only) onto cor res pon ding notch on rear log as shown in Figure 18A . The front of the Left ...

  • Milwaukee LSVFSD-LP - page 12

    12 NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. T op Burner Air Shutter Adjustment Procedure 1. If y ou h ave blue flame or the top burn er is no t ca rryi ng over and b urni ng on all por ts, the air shutter may need to be adjusted to 1/8" ga p for bot h Na tura l an d Pr opan e ga s. 2. Check to see if the air shutte r is set to 1/8& ...

  • Milwaukee LSVFSD-LP - page 13

    NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. 13 An expan ded vie w of the app lian ce with numbe red par ts a nd a part s li st can be f ound on Page 19 . All part s sho uld b e ord ered throu gh yo ur di stri buto r or deal er. Par ts w ill be s hipp ed a t pr evai ling pri ces at t ime of o rder . When ordering repair parts, always give th ...

  • Milwaukee LSVFSD-LP - page 14

    NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. 14 Standard Remote Control System (Model RCL) The Model RCL (Standard) Remote Control System, features a simplistic on/off control function for the fireplace. This model includes a hand-held transmitter , a remote receiver with wall-mount cover plate and all hardware required to install the unit. ...

  • Milwaukee LSVFSD-LP - page 15

    NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. 15 ACCESSORY COMPONENTS (CONTINUED) * Fo r us e wit h ga s tra in m odels LSV FSD-N G an d LSV FSD- LP on ly 18" Gas Log Set 24" Gas Log Set Charred Ember Kit* Cat. No. Model No. Description H689 4 LSVF SD-C EK Char red Ember Kit Charred Ember Kit An optional 2-piece Charred Ember Kit is ...

  • Milwaukee LSVFSD-LP - page 16

    NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. 16 * For the purpose of input adjustment. PILOT (O.D.S.) ASSEMBLY THERMOPI LE WHITE WHITE WHITE RED MILLIVOL T V AL VE ON/OFF SWITCH PILOT PIEZO IGNITER IGNITION WIRE OFF ON OPTIONAL REMOTE CONTROL (MILLIVOL T) Vented/Unvented Gas Log Appliance T echnical Chart For Millivolt Log Set Model No. BTU/ ...

  • Milwaukee LSVFSD-LP - page 17

    17 4. Depress gas control knob slightly and turn clockwise to “OFF .” Do not force. 5. Close lower control compartment. LIGHTING INSTRUCTIONS – MILLIVOL T WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPERTY DAMAGE, PERSONAL INJUR Y OR LOSS OF LIFE. FOR YOUR SAFETY READ BEFORE LIGHTING ...

  • Milwaukee LSVFSD-LP - page 18

    18 VENTED/UNVENTED TROUBLESHOOTING GUIDE OBSERVED PROBLEM POSSIBLE CAUSE REMEDY 1. When igniter button is pressed, there is no spark at ODS/pilot. A. Igniter electrode positioned wrong. Replace igniter . B. Igniter electrode broken. Replace igniter . C. Igniter electrode not connected to igniter cable. Reconnect igniter cable. D. Igniter cable pinc ...

  • Milwaukee LSVFSD-LP - page 19

    19 NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. REPLACEMENT P ARTS LIST (MILLIVOL T) - SHADOWDANCE™ SERIES Replacement Parts List (Millivolt) - Shadowdance™ Series, Models LSVFSD-NG and LSVFSD-LP (18" and 24") No. Description Catalog Number 1. Valve, Millivolt (Natural) H1203 Valve, Millivolt (Propane, L.P .G.) H4278 2. Ember B ...

  • Milwaukee LSVFSD-LP - page 20

    FPO Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2007 by Lennox Hearth Products P/N 850,051M REV . B 11/2007 1110 West T aft ...

Produzent Milwaukee Kategorie Fire Pit

Dokumente, die wir vom Produzenten des Geräts Milwaukee LSVFSD-LP erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Milwaukee
- Bedienungsanleitungen LSVFSD-LP
- Produktkarten Milwaukee
- Informationsbroschüren
- oder Energieetiketten Milwaukee LSVFSD-LP
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Milwaukee LSVFSD-LP.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Milwaukee LSVFSD-LP, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Milwaukee LSVFSD-LP. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Milwaukee LSVFSD-LP ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Milwaukee LSVFSD-LP, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Milwaukee LSVFSD-LP hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Milwaukee LSVFSD-LP verständlich ist.

Eine gänzliche Bedienungsanleitung von Milwaukee sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Milwaukee LSVFSD-LP bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Milwaukee LSVFSD-LP befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Milwaukee LSVFSD-LP, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Milwaukee LSVFSD-LP - die uns die ersten Schritte während der Nutzung von Milwaukee LSVFSD-LP erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Milwaukee LSVFSD-LP hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Milwaukee LSVFSD-LP im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Milwaukee LSVFSD-LP?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Milwaukee LSVFSD-LP nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Milwaukee LSVFSD-LP hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.