    MR. HEA TER, INC., 4 560 W . 1 60 TH ST ., CLEVEL AND, OHIO 44 1 3 5 · 2 1 6-9 1 6-3000 W ARNING: If the information in this manual is not followed exactly , a re or explosion may result causing property damage, personal injury , or loss of life. - Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or an ...

  • Enerco TSVFB20LPT - page 2

    2 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters This appliance may be installed in an aftermarket* permanently manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with a ...

  • Enerco TSVFB20LPT - page 3

    3 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters 9. Operating heater above elevations of 4,500 feet could cause pilot/ODS to shutdown heater . 10. Always run heater with control knob in a locked po - sition. Never set control knob between locked posi - tions. Poor combustion and higher levels of carbon mono ...

  • Enerco TSVFB20LPT - page 4

    4 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters Product Features Figure 1 SAFETY DEVICE This heater has a pilot with an Oxygen Depletion Sen - sor (ODS) safety shut off system. The ODS/pilot shuts off the heater if there is not enough fresh air . IGNITION SYSTEM – The heater is equipped with an electroni ...

  • Enerco TSVFB20LPT - page 5

    5 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters *Adjoining rooms are communication only if there are doorless passageways or ventilation grills be - tween them. DETERMINING THE TYPE OF HEA TER LOCA TION SP ACE: Use this method to determine if you have a conned or unconned space. Note: the space inclu ...

  • Enerco TSVFB20LPT - page 6

    6 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters *A CSA/AGA certied equipment shutoff valve with 1/8” NPT tap is an acceptable alternative to test gauge connection. Purchase a CSA/AGA certied equipment shutoff valve from your dealer . LOCA TING HEA TER This heater is designed to be mounted on the wa ...

  • Enerco TSVFB20LPT - page 7

    7 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters Figure 4 F ASTENING HEA TER TO W ALL Mounting Bracket The mounting bracket in located on the back panel of heater (see gure 5). It has been taped there for ship - ping. Remove mounting bracket from back panel. Figure 5 Removing Front Panel of Heater 1. Rem ...

  • Enerco TSVFB20LPT - page 8

    8 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters 1. Drill holes at marked locations using 5/16” drill bit. For solid walls (concrete or masonry), drill at least 1” deep. 2. Fold wall anchor as shown in gure 8 below . Figure 8. 3. Insert wall anchor (wings rst) into hole. T ap anchor ush to wall ...

  • Enerco TSVFB20LPT - page 9

    9 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters W ARNING: This appliance requires a 3/8” NPT (National Pipe Thread) inlet connection to the pressure regulator . Use of oor mounting feet will require you to use a 3/8 NPT street elbow to make gas connection. CAUTION: Never conne ct heater directly to th ...

  • Enerco TSVFB20LPT - page 10

    10 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters Equipment Shutoff V alve Open Closed Figure 15 ELECTRICAL WIRING DIAGRAM: If any original wiring as supplied with the heater must be replaced, it must be replaced with type A WG 105 o C wire or its equivalent except as indicated. W ARNING: Electrical Groundi ...

  • Enerco TSVFB20LPT - page 11

    11 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters 9. T o select the desired heat level, turn the temperature setting knob counterclockwise to between 1 & 5. THERMOST A T CONTROL OPERA TION FOR IR20LPT / IR30LPT : The thermostatic control used simply turns on and off the burner . FOR BF20LPT / BF30LPT : ...

  • Enerco TSVFB20LPT - page 12

    12 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters A yellow tip on the pilot ame indicates dust and dirt in the pilot assembly . T o clean the pilot assembly nd the small pilot air inlet hole about two inches from where the pilot ame comes out of the pilot assembly (see gure 25). With the unit of ...

  • Enerco TSVFB20LPT - page 13

    13 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters This page intentionally left blank. ...

  • Enerco TSVFB20LPT - page 14

    14 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters OBSERVED SYMPT OM POSSIBLE CAUSE REMEDY When ignitor button is pressed in, there is no spark at pilot 1. Ignitor electrode positioned wrong. 2. Ignitor electrode is broken. 3. Ignitor electrode not connected to ignitor . 4. Ignitor cable pinched or wet. 5. B ...

  • Enerco TSVFB20LPT - page 15

    15 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters Burner does not light after ODS/pilot is lit 1. Burner orice is clogged 2. Burner orice diameter to small 3. Inlet gas pressure is too low 1. Clean burner orice (see Cleaning and Maintenance on page 1 1), or replace burner orice 2. Replace burner ...

  • Enerco TSVFB20LPT - page 16

    16 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters IR20LPT IR30LPT BF20LPT BF30LPT 7 2 36 39 38 35 16 21 16-1 16-2 6 26 29 24 22-3 13 23 18 3 11 1-2 1-4 22-2 33-1 22-1 25 9 5 1-3 1-1 27-1 28-1 4 44 42 45 8 20 10 15 14 42 9 7 26 22-3 22-1 33-1 1-4 3 6 11 45 4 16 2 27-2 28-2 44 13 23 1-2 1-3 5 29 24 1-1 25 22- ...

  • Enerco TSVFB20LPT - page 17

    17 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters For all models, Equipment shutoff valve with 1/8” NPT tap. IR20LPT , IR30LPT , BF20LPT , BF30LPT , BF20LPT , BF30LPT • P ARTS LIST This list contains replacement parts used in your heater . When ordering parts, follow the instructions listed under Replac ...

  • Enerco TSVFB20LPT - page 18

    18 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters ITEM P ART NO. DESCRIPTION QTY . IR20LPT BF20LPT IR30LPT BF30LPT 37 – – – – – – 38 70677 – 70677 – Burner Plaques, 30 4 39 70677 – 70677 – Burner Plaques, 20 3 40 70678 – 70678 – Plaques Gasket, 30 4 41 70678 – 70678 – Plaques Gas ...

  • Enerco TSVFB20LPT - page 19

    19 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters This page intentionally left blank. ...

  • Enerco TSVFB20LPT - page 20

    20 Installation Instructions and Owner ’ s Manual Unvented LP-Gas V ent Free Room Heaters Model # Start Serial# MHVFR2 0LPT 7 05 5 500 1 7 088 HSVFR2 0LPT 7 0 5 5 500 1 7 088 TSVFR2 0LPT 7 05 5 500 1 7 088 MHVFR30LPT 7 0 56 500 299 5 1 HSVFR30LPT 7 0 56 500 299 5 1 TSVFR30LPT 7 05 6 500 2 995 1 MHVFB2 0LPT 7 05 2 500 22 5 2 7 HSVFB2 0LPT 7 0 5 2 ...

Produzent Enerco Kategorie Gas Heater

Dokumente, die wir vom Produzenten des Geräts Enerco TSVFB20LPT erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Enerco
- Bedienungsanleitungen TSVFB20LPT
- Produktkarten Enerco
- Informationsbroschüren
- oder Energieetiketten Enerco TSVFB20LPT
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Enerco TSVFB20LPT.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Enerco TSVFB20LPT, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Enerco TSVFB20LPT. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Enerco TSVFB20LPT ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Enerco TSVFB20LPT, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Enerco TSVFB20LPT hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Enerco TSVFB20LPT verständlich ist.

Eine gänzliche Bedienungsanleitung von Enerco sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Enerco TSVFB20LPT bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Enerco TSVFB20LPT befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Enerco TSVFB20LPT, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Enerco TSVFB20LPT - die uns die ersten Schritte während der Nutzung von Enerco TSVFB20LPT erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Enerco TSVFB20LPT hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Enerco TSVFB20LPT im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Enerco TSVFB20LPT?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Enerco TSVFB20LPT nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Enerco TSVFB20LPT hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)