Belshaw Brothers and 734CG - page 1
Gas Fryer Models 718LCG, 724CG, and 734CG Operator’s Manual Serial # W 06060001 - on If you accept the machine from the shipping company, you are, in effect, saying that the machine is in good condition, and you must pay for the machine. Belshaw cannot pay for shipping damage, because the freight company has accepted the machine from Belshaw in g ...
-
Belshaw Brothers and 734CG - page 2
EQUIPMENT RECORD Please provide the information below when you correspond with us about your machine. Purchased by _____________________________________________________________________ Installed by ______________________________________________________________________ Date of Installation ____________________________________________________________ ...
-
Belshaw Brothers and 734CG - page 3
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN iii Contents Sections 1 Installation 1 Conforming to Codes 1 Selecting a Workstation 1 Unpacking the Fryer 2 Initial Cleaning 2 Assembling the Fryer 2 Installing the Fryer 3 Moving the Fryer 4 2 ...
-
Belshaw Brothers and 734CG - page 4
B Donut-Making Helps B-1 Tips on Making Quality Cake Donuts B-1 Calculating Correct Water Temperature B-2 Ratios of Plunger Sizes to Donut Weights B-2 Temperature Conversion B-2 C Parts Lists C-1 Limited Warranty Insert ...
-
Belshaw Brothers and 734CG - page 5
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN v Preface The 718LCG, 724CG, and 734CG Gas Fryers are designed to fry cake and yeast-raised donut products. Each must be bolted to a flat, dry floor. The operator should stand opposite the flue s ...
-
Belshaw Brothers and 734CG - page 6
Contact Belshaw Brothers at 1-800-578- 2547 to obtain necessary parts and instructions. ...
-
Belshaw Brothers and 734CG - page 7
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 1 1 Installation In a prominent location, post instructions to be followed in the event the user smells gas. Obtain this information by consulting your local gas supplier. FOR YOUR SAFETY Do not ...
-
Belshaw Brothers and 734CG - page 8
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 2 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers The workstation should allow at least 2”/5 cm clearance between the machine and all construction, whether combustible or noncombustible. In addition, it should allow access to the rear of the ...
-
Belshaw Brothers and 734CG - page 9
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 3 3. Put the heat shield and splash shield on the fryer. They slide over the flue stack, and the back of the kettle slides between the heat shield and the splash shield. The mounting holes in the ...
-
Belshaw Brothers and 734CG - page 10
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 4 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers gas supply line on the fryer itself is 1/2”/1.3 cm I.P.S.) b. Connect the fryer to the building’s gas supply. c. Seal all threaded joints between gas pipes with pipe joint compound. You mus ...
-
Belshaw Brothers and 734CG - page 11
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 5 Operation 2 Taking Safety Precautions In a prominent location, post information about what to do if there is a gas leak. Make sure that all employees know what to do. WARNING To avoid the possi ...
-
Belshaw Brothers and 734CG - page 12
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 6 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers 4. Move the on/off switch to the OFF position. 5. Rotate the gas control knob counterclock- wise to the ON position. 6. Move the on/off switch to the ON position. The yellow pilot light near th ...
-
Belshaw Brothers and 734CG - page 13
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 7 CAUTION To avoid damaging the machine, do not operate the conveyor until all the shortening has melted. 11. Continue supplying shortening to the kettle as required. Keep the kettle filled up to ...
-
Belshaw Brothers and 734CG - page 14
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 8 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers 3 Cleaning For your safety, observe the following warnings throughout the entire cleaning process. WARNING Thoroughly clean and dry the floor if shortening, water, or other materials are spille ...
-
Belshaw Brothers and 734CG - page 15
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 9 WARNING Do not allow the shortening to overflow the containers. Shortening will get on the floor, and if the shortening is not cool enough, you may be burned. WARNING Thoroughly clean and dry t ...
-
Belshaw Brothers and 734CG - page 16
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 10 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers WARNING Do not allow the cleaning solution to overflow the containers. Cleaning solution will get on the floor, and if the solution is not cool enough, you may be burned. 8. When the draining ...
-
Belshaw Brothers and 734CG - page 17
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 11 Maintenance 4 SB-0308 rev 3 AFFECTS: OPEN KETTLE FRYERS PURPOSE: PROGRAMMING THE OGDEN ETR-9000 TEMPERATURE CONTROLLER NOTE: Use Rev. 3 to correct existing open Kettle Fryer settings. (SP1L se ...
-
Belshaw Brothers and 734CG - page 18
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 12 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers Menu Overview: There are three main menus that contain parameters that require programming; they are User Menu, Setup Menu, and Calibration Mode. The figure below (Figure 2) shows the sequence ...
-
Belshaw Brothers and 734CG - page 19
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 13 Open Kettle Fryer Parameter Settings Tables 1, 2 and 3 below list of the temperature controller default settings and the Belshaw Factory settings. When installing a new controller 4 of the def ...
-
Belshaw Brothers and 734CG - page 20
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 14 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers Table 1 - Parameter Descriptions Set to 375 ºF set to “uSEr” after setup 0ºF 410ºF 0ºF ...
-
Belshaw Brothers and 734CG - page 21
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 15 Table 2 - Parameter Descriptions Set to “nonE” ...
-
Belshaw Brothers and 734CG - page 22
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 16 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers Table 3 - Parameter Descriptions Set to ...
-
Belshaw Brothers and 734CG - page 23
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 17 5 Troubleshooting If you have a problem with your fryer that you cannot solve, call your dealer or another qualified technician. If your dealer cannot help you, please call Belshaw Bros. at (2 ...
-
Belshaw Brothers and 734CG - page 24
...
-
Belshaw Brothers and 734CG - page 25
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN A-1 A Pilot Module This appendix contains supplemental information about the Honeywell S8600 Intermittent Pilot Module. The Belshaw 718LCG, 724CG, and 734CG gas fryers all use this module. Fryers ...
-
Belshaw Brothers and 734CG - page 26
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 A-2 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers module will not energize the second main valve, and the main burner will not light. The S8600F, which is used on natural gas fryers, will continue to spark as long as the fryer’s thermostat ...
-
Belshaw Brothers and 734CG - page 27
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN A-3 Figure A-1. Normal Operating Sequence. ST A R T TRIAL FO R IGN ITIO N MA I N BUR NE R OP E R A T ION T her mos tat c al l s for heat. F i r s t mai n v al v e opens . G as fl ow s to pi l ot ...
-
Belshaw Brothers and 734CG - page 28
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 A-4 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers Step 5: Check Normal Operation 1. Set the fryer’s thermostat above 200°F/93°C. 2. Watch to see whether the pilot lights smoothly when the gas reaches the pilot burner. 3. Watch to see whe ...
-
Belshaw Brothers and 734CG - page 29
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN A-5 A common ground, usually supplied by the pilot burner bracket, is required for the module and the pilot burner/igniter-sensor. 1. Check for good metal-to-metal contact between the pilot burne ...
-
Belshaw Brothers and 734CG - page 30
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 A-6 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers c. Make sure the electrical connections are clean and tight. Replace damaged wire with moisture-resistant #18 wire rated for continuous duty up to 221°F/105°C. d. Check to see if ceramic in ...
-
Belshaw Brothers and 734CG - page 31
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN B-1 B Donut-Making Helps Tips on Making Quality Cake Donuts • Use the correct batter temperature. In general, the correct batter temperature is 75 ° -80 ° F/24 ° -27 ° C. Check the mix manu ...
-
Belshaw Brothers and 734CG - page 32
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 B-2 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers Calculating Correct Water Temperature The following is an example of how to calculate the correct water temperature to use. You must use your own room temperature, dry m ix temperature, desir ...
-
Belshaw Brothers and 734CG - page 33
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN C-1 C Parts Lists The following pages contain lists of the parts that make up the 718LCG, 724CG, and 734CG Gas Fryers. Each parts list refers to an exploded- view assembly drawing. You can use th ...
-
Belshaw Brothers and 734CG - page 34
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 C-2 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers 718LCG PARTS LIST. ITEM NUMBER QTY PER UM DESCRIPTION-TRUNC. 232 1 EA POWER CORD, 18GA SJO #PLT-0001 1 EA CLEAR NEON PILOT LIG #PLT-0002 1 EA CLEAR NEON PILOT LIG 618-0007A 2 EA PROOFING SCRE ...
-
Belshaw Brothers and 734CG - page 35
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN C-3 718LCG PARTS LIST (CONT’D) ITEM NUMBER QTY PER UM DESCRIPTION-TRUNC. 724G-0183 1 EA SHORTENING CAUTION L 724G-0186 2 EA DOOR MAGNET 724G-0188 2 EA HINGE PIN 724G-0200 1 EA ELECTRICAL BOX CO ...
-
Belshaw Brothers and 734CG - page 36
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 C-4 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers 724CG PARTS LIST. ITEM NUMBER QTY PER UM DESCRIPTION-TRUNC. 135 1 EA PLUG,BRASS 1/8 I.P.S 618L-0098 1 EA DRAIN VALVE KNOB,EXT 618L-0103 1 EA LABEL,DRAIN VALVE 618L-0105 2 EA WARNING LABEL 618 ...
-
Belshaw Brothers and 734CG - page 37
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN C-5 734CG PARTS LIST. ITEM NUMBER QTY PER UM DESCRIPTION-TRUNC. 232 1 EA POWER CORD, 18GA SJO #PLT-0001 1 EA CLEAR NEON PILOT LIG #PLT-0002 1 EA CLEAR NEON PILOT LIG 618L-0098 1 EA DRAIN VALVE KN ...
-
Belshaw Brothers and 734CG - page 38
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 C-6 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers 0080A 5 ...
-
Belshaw Brothers and 734CG - page 39
Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN C-7 734FG PARTS LIST ITEM NUMBER QTY PER UM DESCRIPTION-TRUNC. FM200-0102 6 EA FIBER WASHER 3/4OD 1 FT100-0063 2 EA SUPPORT BRACKET H-0024 6 EA WASHER GREY FIBER 1/16 MDD-0459 1 EA LABEL,WARNING ...
-
Belshaw Brothers and 734CG - page 40
...
-
Belshaw Brothers and 734CG - page 41
Belshaw Brothers Inc. 1750 22 nd Avenue S. Seattle, WA 98144-4590 Phone (206) 322-5474 Fax: (206) 322-5425 Revised 04/04/2006 US/Canada/Mexico Limited Warranty Page 1 US/Canada/Mexico Limited Warranty and Return Policy Belshaw Brothers Inc. warrants parts of its manuf acture and assembly of equipment to be free from defects in workmanship and mater ...
-
Belshaw Brothers and 734CG - page 42
Belshaw Brothers Inc. 1750 22 nd Avenue S. Seattle, WA 98144-4590 Phone (206) 322-5474 Fax: (206) 322-5425 Revised 04/04/2006 US/Canada/Mexico Limited Warranty Page 2 Exclusions This warranty excludes from its coverage and does not apply to: (a) solenoid and relay coils; (b) lamps; (c) “O” rings; (d) belts; and (e) impellers. These items are ex ...
Haben Sie eine Frage bezüglich Belshaw Brothers and 734CG?
Nutzen Sie das untere Formular
Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Belshaw Brothers and 734CG nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Belshaw Brothers and 734CG hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.