Bedienungsanleitung Miller Electric S-32S

28 Seiten 0.77 mb
Download

Zur Seite of 28

Summary
  • Miller Electric S-32S - page 1

    Visit our website at www.MillerWelds.com OM-1546 090 004M August 2000 Processes Description MIG (GMA W) W elding Flux Cored (FCA W) W elding Wire Feeder S-32S And S-32SL ...

  • Miller Electric S-32S - page 2

    Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual catalog sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .MillerW eld ...

  • Miller Electric S-32S - page 3

    T ABLE OF CONTENTS SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2. Arc Welding Hazards 1 . . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric S-32S - page 4

    ...

  • Miller Electric S-32S - page 5

    OM-1546 Page 1 SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING som _nd_4/98 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. Y Marks a special safety message. . Means “Note”; not safety related. This group of symbols means W arning! W atch ...

  • Miller Electric S-32S - page 6

    OM-1546 Page 2 Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld. ARC RA YS can burn eyes and skin. D Wear a welding helmet fitted with a proper shade of filter to protect your face and eyes when welding or watching (see ANSI Z49.1 and Z8 ...

  • Miller Electric S-32S - page 7

    OM-1546 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring – be sure power supply system is properly sized, rated, and protected to handle this unit. F ...

  • Miller Electric S-32S - page 8

    OM-1546 Page 4 1-5. EMF Information Considerations About W elding And The Effects Of Low Frequency Electric A n d M a g netic Fields W elding current, as it flows through welding cables, will cause electro- magnetic fields. There has been and still is some concern about such fields. However , after examining more than 500 studies spanning 17 years ...

  • Miller Electric S-32S - page 9

    OM-1546 Page 5 SECTION 1 – CONSIGNES DE SECURITE – LIRE A V ANT UTILISA TION som _nd_fre 4/98 1-1. Signification des symboles Signifie Mise en garde ! Soyez vigilant ! Cette proc é dure pr é sente des risques de danger ! Ceux-ci sont identifi é s par des symboles adjacents aux directives. Y Identifie un message de s é curit é particulier . ...

  • Miller Electric S-32S - page 10

    OM-1546 Page 6 Le rayonnement de l ’ arc du proc é d é de soudage g é n è re des rayons visibles et invisibles intenses (ultraviolets et infrarouges) susceptibles de provoquer des br û lures dans les yeux et sur la peau. Des é tincelles sont projet é es pendant le soudage. LES RA YONS DE L ’ ARC peuvent pro- voquer des br û lures dans l ...

  • Miller Electric S-32S - page 11

    OM-1546 Page 7 1-3. Dangers suppl é mentaires en relation avec l ’ installation, le fonctionnement et la maintenance Risque D ’ INCENDIE OU D ’ EXPLOSION. D Ne pas placer l ’ appareil sur , au-dessus ou à proxi- mit é de surfaces infllammables. D Ne pas installer l ’ appareil à proximit é de produits inflammables D Ne pas surcharger ...

  • Miller Electric S-32S - page 12

    OM-1546 Page 8 1-4. Principales normes de s é curit é Safety in W elding and Cutting, norme ANSI Z49.1, de l ’ American Wel- ding Society , 550 N.W . Lejeune Rd, Miami FL 33126 Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent of Documents, U.S. Government Printing Of fice, Washington, D.C. 20402. Recommended Safe Practice for the ...

  • Miller Electric S-32S - page 13

    OM-1546 Page 9 SECTION 2 – INST ALLA TION 2-1. Specifications T ype Of Input Power W elding Power Source T ype Wire Feed Speed Range Wire Diameter Range Input W elding Circuit Rating Max. Wire Spool Capacity Overall Dimensions W eight Open-Circuit/ Arc V oltage, 15 T o 100 V olts DC Constant V oltage (CV) Or Constant Current (CC) DC Standard: 50 ...

  • Miller Electric S-32S - page 14

    OM-1546 Page 10 2-2. Installing And Aligning Wire Guide And Drive Roll 3/16 in Ref. ST-091 547-D / Ref. ST -1 12 370-C / S-0856 When changing wire size or type, check drive roll and wire guide size (see Parts List). Installing Wire Guide And Drive Rolls: 1 Drive Roll Nut 2 Drive Roll Carrier Turn nut one click until lobes of nut line u p with lobes ...

  • Miller Electric S-32S - page 15

    OM-1546 Page 1 1 1 CV Welding Power Source With 24 V AC Power 2 CC Welding Power Source Without Contactor 3 External Secondary Contactor 4 Remote Contactor Cord 5 Weld Cable 6 W ork 2-3. T ypical Connections 1 6 5 6 5 3 2 4 1 Gun Securing Knob 2 Gun Block 3 Gun Outlet Wire Guide Loosen knob, insert gun into block. Position outlet wire guide as clos ...

  • Miller Electric S-32S - page 16

    OM-1546 Page 12 1 Gas Hose With 5/8-18 Right- hand Thread Fittings (Cus- tomer Supplied) 2-5. Connecting Shielding Gas (Optional) Ref. ST-158 789 T ools Nee d e d : 1 5/8 in 2-6. Installing W elding Wire And Adjusting Hub T ension Ref. ST-158 788 / ST -091 601-A 1 Retaining Ring 2 Wire Spool 3 Hub 4 Spool Support If necessary , move hub on support ...

  • Miller Electric S-32S - page 17

    OM-1546 Page 13 1 Pressure Assembly Adjust- ment Knob Lay gun cable out straight. A Open pressure assembly , hold wire tightly , and cut of f end. Push wire through guides into gun. B Close and tighten pressure assembly . Press gun trig- ger until wire comes out gun. C T o adjust wire pressure, feed wire against wooden surface and tighten knob so w ...

  • Miller Electric S-32S - page 18

    OM-1546 Page 14 SECTION 3 – OPERA TION 3-1. Controls Ref. ST-091 547-D / ST -176 214 2 4 Selector Switch for T ype of Power Source Constant V oltage CV Constant Current (drooper) CC S-090 438-D 1 Wire Speed Control (See Sec- tion 3-2) 2 Power Control Switch 3 Circuit Breaker CB1 CB 1 protects wire feeder from over- load. Correct problem and manua ...

  • Miller Electric S-32S - page 19

    OM-1546 Page 15 Wire Speed Setting CC Mode 100 90 80 70 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 222 254 268 295 314 342 365 388 406 429 452 480 498 526 549 572 595 623 205 234 246 271 288 313 334 354 370 391 412 437 453 478 499 520 541 566 188 213 224 246 261 284 302 320 335 353 372 394 408 430 449 468 486 508 170 193 203 222 235 254 2 ...

  • Miller Electric S-32S - page 20

    OM-1546 Page 16 SECTION 4 – MAINTENANCE & TROUBLESHOOTING 4-1. Routine Maintenance Y Disconnect power before maintaining. 3 Months Replace Unreadable Labels Clean And T ighten W eld T erminals Repair Or Replace Cracked W eld Cable Gas Hose Gun Cable Replace Cracked Parts 6 Months Blow Out Or V acuum Inside, During Heavy Service, Clean Monthly ...

  • Miller Electric S-32S - page 21

    OM-1546 Page 17 SECTION 5 – ELECTRICAL DIAGRAM SB-176 227 Figure 5-1. Circuit Diagram For Wire Feeder ...

  • Miller Electric S-32S - page 22

    OM-1546 Page 18 SECTION 6 – P ARTS LIST Figure 6-1. Main Assembly ST-091 506-K . Hardware is common and not available unless listed. 1 2 3 4 5 6 7 8 9 10 11 13 14 15 16 15 14 17 18 19 22 21 20 12 23 24 25 26 27 28 29 30 – FIG. 6 – 2 31 33 34 35 36 32 37 38 39 40 41 42 ...

  • Miller Electric S-32S - page 23

    OM-1546 Page 19 Figure 6-1. Main Assembly Description Quantity Part No. Dia. Mkgs. Item No. 1 097 770 LABEL, warning electric shock can kill 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 +089 818 WRAPPER 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric S-32S - page 24

    OM-1546 Page 20 Figure 6-2. Motor & Wire Drive Assembly (Fig 6-1 Item 30) Description Quantity Part No. Dia. Mkgs. Item No. 1 166 338 LEVER, mtg pressure gear 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 166 072 SP ACER, gear 1 . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric S-32S - page 25

    OM-1546 Page 21 T able 6-1. Drive Roll & Wire Guide Kits Base selection of drive rolls upon the following recommended usages: 1. V -Grooved rolls for hard wire. 2. U-Grooved rolls for soft and soft shelled cored wires. 3. U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types). 4. V -Knurled rolls for hard shelled cored w ...

  • Miller Electric S-32S - page 26

    OM-1546 Page 22 Notes ...

  • Miller Electric S-32S - page 27

    Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 7/00 Y o ur distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor . The expertise ...

  • Miller Electric S-32S - page 28

    PRINTED IN USA  2000 Miller Electric Mfg. Co. 6/00 Miller Elect ric Mfg. Co. An I l li noi s T ool Works Com pany 1635 W est S pencer St reet Applet on, WI 54914 USA International He adquarters – USA USA Phone: 920-735-4505 Auto-A t t ended USA & Canada F AX : 920-735-4134 Int ernati onal FAX: 920-735-4125 European Headqua rters – United ...

Produzent Miller Electric Kategorie Welder

Dokumente, die wir vom Produzenten des Geräts Miller Electric S-32S erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Miller Electric
- Bedienungsanleitungen S-32S
- Produktkarten Miller Electric
- Informationsbroschüren
- oder Energieetiketten Miller Electric S-32S
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Miller Electric S-32S.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Miller Electric S-32S, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Miller Electric S-32S. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Miller Electric S-32S ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Miller Electric S-32S, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Miller Electric S-32S hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Miller Electric S-32S verständlich ist.

Eine gänzliche Bedienungsanleitung von Miller Electric sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Miller Electric S-32S bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Miller Electric S-32S befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Miller Electric S-32S, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Miller Electric S-32S - die uns die ersten Schritte während der Nutzung von Miller Electric S-32S erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Miller Electric S-32S hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Miller Electric S-32S im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Miller Electric S-32S?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Miller Electric S-32S nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Miller Electric S-32S hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)