    COMSPHERE 3550 SERIES DA T A SERVICE UNITS MODELS 3550 AND 3551 QUICK REFERENCE Document No. 3550-A2-GL10-10 ...

  • Paradyne 3551 - page 2

    Copyright  1999 Paradyne Corporation. All rights reserved. Printed in U.S.A. Notice This publication is protected by federal copyright law . No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, m ...

  • Paradyne 3551 - page 3

    496-15149 TM 1 COMSPHERE 3550 SERIES DA T A SER VICE UNITS MODELS 3550 AND 3551 Quick Reference Document Number 3550-A2-GL10-10 March 1999 Product Documentation on the W orld Wide W eb We provide complete product documentation online. This lets you search the documentation for specific topics and print only what you need, reducing the waste of surp ...

  • Paradyne 3551 - page 4

    2 Changing the Model 3550 DSU Hardware Straps The Model 3550 DSU has a switch located behind its diagnostic control panel (DCP). This switch contains two straps, one that controls the permissive or programmable connection when a DBM is installed, and one that controls the frame-to-signal grounds. T able 1 shows the DSU’s settings.  Procedur e ...

  • Paradyne 3551 - page 5

    3 T able 1. Model 3550 DSU Switch Settings Switch Position Switch Setting Function S1 1 ON (default) Permissive V .32 DBM transmit output level of –9 dBm S1-1 Off Programmable V .32 DBM transmit level between –12 dBm and 0 dBm S1 2 ON Frame ground (FG) connected to signal ground (SG) S1-2 Off (default) FG connected to SG through 100 ohm resisto ...

  • Paradyne 3551 - page 6

    4 Installing the Model 3550 DSU Before installing the DSU, label the circuit breaker that protects the ac wall outlet, and make sure that it is set to ON. Then, proceed with the installation.  Procedur e 1. Place the DSU in its planned location. Make sure the ventilation slots are not blocked. 2. At the rear of the DSU, insert the ac transformer ...

  • Paradyne 3551 - page 7

    5 Connecting the Model 3550 DSU to the NMS A 3600 Hubbing Device is required to connect the control DSU to the 6700 Series NMS. When connected to the NMS, the DSU can be controlled and configured from the NMS rather than from the DCP alone.  Procedur e 1. Plug the 4-pin modular plug of the 3600 Hubbing Device into the DSU jack labeled CC/DC. 2. ...

  • Paradyne 3551 - page 8

    6 Connecting the Model 3550 DSU to the Dial Network (PSTN) If your DSU is equipped with a V .32 DBM, follow these steps.  Procedur e 1. Plug either end of the dial (analog) interface cable into the DSU jack labeled BACKUP . — Permissive service – telephone cord with 6-pin modular RJ1 1C plug — Programmable service – telephone cord with 8 ...

  • Paradyne 3551 - page 9

    7 Connecting the Model 3550 DSU to the DDS (or LADS) Network NOTE: Before connecting the DSU to the DDS network, ensure that approved primary protectors have been installed on the circuit in accordance with Article 800 of the National Electric Code, NFP A 70, in the United States and Section 60 of the Canadian Electric Code, Part 1, in Canada. Foll ...

  • Paradyne 3551 - page 10

    8 Connecting the Model 3550 DSU to a DTE The DSU’s rear panel has both a 25-pin EIA-232-D/V .24 connector and a 34-pin ITU-T V .35 connector (used for higher operating speeds). Y ou can use either interface. When the unit is equipped with a TDM/Flex, either of these interfaces can be used as Port 1. The TDM/Flex provides an additional interface t ...

  • Paradyne 3551 - page 11

    9 Connecting the Model 3550 DSU’ s Port 2 For the EIA-232 cable, install as described above. For the V .35 cable, install the V .35 adapter , then the V .35 DTE cable as follows.  Procedur e 1. Reconfigure the port for a V .35 interface. See General Configuration Options on page 21. 2. Connect the 25-pin plug end of the V .35 adapter (Feature ...

  • Paradyne 3551 - page 12

    10 T able 2. Model 3551 DSU Switch Settings Switch Position Switch Setting Function S1 1 ON (default) Permissive V .32 DBM transmit output level of –9 dBm S1-1 Off Programmable V .32 DBM transmit level between –12 dBm and 0 dBm ON Frame ground (FG) connected to signal ground (SG) S1-2 Off (default) FG connected to SG through 100 ohm resistor ON ...

  • Paradyne 3551 - page 13

    11 T able 3. Model 3551 DSU Jumper Straps Strap Designation State of Jumper Strap Function J12 Left V .35 T est Mode Indication: Left — Enables V .35 T est Mode Indication (Pins 1 and 2). This is the factory default. Right — Disables V .35 T est Mode Indication (Pins 2 and 3). J13 Left EIA-232-D T est Mode Indication: Left — Enables EIA-232-D ...

  • Paradyne 3551 - page 14

    12 Installing the Model 3551 DSU The initial installation procedure for the Model 3551 DSU requires the installation of a rear connector plate onto the rear of the COMSPHERE 3000 Series Carrier . After the initial installation, the DSU can be installed or uninstalled by simply removing the DSU from the carrier .  Procedur e 1. At the rear of the ...

  • Paradyne 3551 - page 15

    13 5. At the front of the carrier , hold the DSU vertically with the latch on its faceplate in the open position. Then, insert the circuit card into the top and bottom circuit card guides for the slot that contains the rear connector plate. Slide the DSU into the slot, aligning the circuit card with the rear connector plate until the connectors sea ...

  • Paradyne 3551 - page 16

    14 7. At the rear of the carrier , connect the appropriate DTE interface cable (EIA-232-D or V .35) to the rear connector plate. For an EIA-232-D interface cable, connect the EIA-232-D cable to the top DTE connector on the rear connector plate. For the 25-pin V .35 interface, a V .35 adapter is shipped with the unit. T o connect a V .35 adapter to ...

  • Paradyne 3551 - page 17

    15 Connecting the Model 3551 DSU to the NMS A Model 3551 DSU is set up for network diagnostic connection through the shared diagnostic unit (SDU), which is installed in Slot 0 of the carrier . Refer to the COMSPHERE 3000 Series Carrier Installation Manual , Document No. 3000-A2-GA31, to set up the network diagnostic connection. For connection of th ...

  • Paradyne 3551 - page 18

    16 T o Connect the SDCP to a DSU For the carrier-mounted Model 3551 DSU, the SDCP must first be reconnected to the DSU. Once connected, the SDCP operates like a DCP .  Procedur e 1. Press the Select key . A screen similar to the following appears. F1 F2 F3 Carr:Slot: 1: 01 A 1:0 2 A The cursor is usually positioned under the second position of t ...

  • Paradyne 3551 - page 19

    17 Addressing the Unit A unique address must be assigned to each control and tributary DSU in your network. Y ou can assign an address within the range of 1 through 255. NOTES: — Do not assign the number 192 as a network address. This number is reserved as a broadcast address. — The numbers 191 and 255 cannot be assigned to a DSU that has a DBM ...

  • Paradyne 3551 - page 20

    18 Power -Up Routine When power is applied, the DSU: H Determines what options (DBM or TDM/Flex) are installed, if any . H Runs a Device T est on itself and each of the installed options. During the tests, all indicators on the DCP light briefly and the message Power-Up T ests appears on the liquid crystal display (LCD). H Displays the results of e ...

  • Paradyne 3551 - page 21

    19 Configuration Options Configuration options are accessed from the Configuration branch of the front panel menu. In the following tables, factory defaults are shown in boldface . If they differ from each other , defaults are shown for PTPC, PTPT , MPTC, and MPTT . Key to symbols:  These configuration options do not appear when Full mode is dis ...

  • Paradyne 3551 - page 22

    20 Diagnostic General Configuration Options V alue Position Cntrl (PTPC, MPTC), T rib (PTPT , MPTT) LinkConfg Pt-Pt (PTPC, PTPT), M-Pt (MPTC, MPTT) Resp Period  1 , 2, 10 T ribTimOut  0:10 (5 sec to 10 min) Link Delay  0s , 1s, 2s, 5s, 10s, 20s, 50s Packet Delay  0s , 1s , 2s, 5s M-PtSymPrt  Enab , Disab DBM Configuration Options V a ...

  • Paradyne 3551 - page 23

    21 General Configuration Options V alue DTE Port EIA232 , V .35 RTS Cntrl FrcOn (PTPC, PTPT , MPTC), DTE (MPTT) CTS Cntrl Std , = RTS, Delay , FrcOn AntiStream  Disab , 1 – 100 sec LSD Lead  Std , Delay , FrcOn DSR FrcOn  Enab , Disab SystemStat  Enab , Disab DSR on T st  Enab , Disab Circ Assur  Enab, Disab RespondRDL  Enab ...

  • Paradyne 3551 - page 24

    22 MUX Port Configuration Options V alue DTE Port EIA232 , V .35 Async → Sync Enab, Disab Async Rate =Sync , 1800, 1200, 600, 300, 150 AsyncBit/Char 6, 7, 8 , 9, 10 Stop Bits 1 , 2 Overspeed 1.25, 2.5 RTS Cntrl FrcOn, DTE TxCarrSel  Const , Cntrl RxCarrSel  Const , Cntrl, Mark PCC Buffer Enab, Disab Elast Stor  Enab, Disab RTS/CTS Del ? ...

  • Paradyne 3551 - page 25

    23 ! Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. This product is intended to be used with a 3-wire grounding type plug – a plug which has a grounding pin. This is a safety feature. Equipment grounding is vital to ensure safe operation. Do not defeat the ...

  • Paradyne 3551 - page 26

    24 Notices ! W ARNING:                           ? ...

  • Paradyne 3551 - page 27

    25 If your DSU causes harm to the telephone network, the telephone company may discontinue your service temporarily . If possible, they will notify you in advance. But if advance notice is not practical, you will be notified as soon as possible. Y ou will be advised of your right to file a complaint with the FCC. If your DSU causes harm to the tele ...

Produzent Paradyne Kategorie Modem

Dokumente, die wir vom Produzenten des Geräts Paradyne 3551 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Paradyne
- Bedienungsanleitungen 3551
- Produktkarten Paradyne
- Informationsbroschüren
- oder Energieetiketten Paradyne 3551
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Paradyne 3551.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Paradyne 3551, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Paradyne 3551. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Paradyne 3551 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Paradyne 3551, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Paradyne 3551 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Paradyne 3551 verständlich ist.

Eine gänzliche Bedienungsanleitung von Paradyne sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Paradyne 3551 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Paradyne 3551 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Paradyne 3551, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Paradyne 3551 - die uns die ersten Schritte während der Nutzung von Paradyne 3551 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Paradyne 3551 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Paradyne 3551 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Paradyne 3551?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Paradyne 3551 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Paradyne 3551 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)