  • Haier AD122AMBHA - page 1

    Operation & Installation Manual No. 0010572410 D DUCT TYPE AIR CONDITIONING AD122AMBHA AU122AABHA (HDU-12HA03/M(R1)(B)) AD092AMBHA AU092AABHA (HDU-09HA03/M(R1)(B)) ...

  • Haier AD122AMBHA - page 2

    1 T ABLE OF CONTENTS MALFUNCTION 7-8 CARE AND MAINTENANCE 9-10 INST ALLA TION MANUAL FOR OUTDOOR UNIT 1 1-14 INST ALLA TION MANUAL FOR INDOOR UNIT 15-20 SAFETY PRECAUTIONS 3-5 P ARTS AND FUNCTIONS 6 CAUTIONS 2 INST ALLA TION MANUAL FOR ELECTRIC WIRING 21 INST ALLA TION MANUAL FOR WIRE CONTROLLER 22 CHECK AND TEST RUN 23 ...

  • Haier AD122AMBHA - page 3

    CAUTIONS 2 All electrical ropairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner . Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or tw ...

  • Haier AD122AMBHA - page 4

    SAFETY PRECAUTIONS Before starting to use the system, read carefully this"SAFETY PRECAUTIONS" to ensure a proper operation of the system. Safety precautions described here are classified to " W ARNING" and " CAUTION". Precautions which are shown in the column of " W ANING" means that an improper handing could ...

  • Haier AD122AMBHA - page 5

    SAFETY PRECAUTIONS 4 CAUTION Do not wash the air conditioner with water . Do not install the system where the air outlet reaches directly the flora and fauna. Make sure to use a fuse of proper electric rating. Do not operate the system while the air outlet grill is removed. It is strictly prohibited to place a container of combustible gas or liquid ...

  • Haier AD122AMBHA - page 6

    SAFETY PRECAUTIONS 5 2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. An extend cord is not recommended, the requirement of the power supply cord is H07RN-F 3G 2.5 mm 2 (suitable for installation in European region) 3. If the fuse on PC board is broken please change it wit ...

  • Haier AD122AMBHA - page 7

    P ARTS AND FUNCTIONS 6 Indoor Unit Outdoor Unit Motor(inside) Fan(inside) Air inlet Air outlet Drain hose Connecting piping and electrical wiring ...

  • Haier AD122AMBHA - page 8

    7 please check the following things about your air conditioner before making a servie call. MALFUNCTION Flickering F1 Note: This unit has a function of automatic restart system after recovering power stoppage. Please contact the sales dealer if it is not required. Content of defect F2 The trouble of the room temp.sensor F4 The trouble of the pipe t ...

  • Haier AD122AMBHA - page 9

    8 MALFUNCTION The followings are not malfunction Shuru Shuru When the air conditioner is started, when the compressor starts or stops during operation or when the air conditioner is stopped, it sometimes sounds "shuru shuru" or "gobo gobo". It is the flowing sound of the refrigerant, and it is not a trouble. W ater flowing sound ...

  • Haier AD122AMBHA - page 10

    9 CARE AND MAINTENANCE Points to observe T urn off the power supply switch. Do not touch with wet hand. Do not use hot water or volatileliquid. ON OFF Thinner Do not use! Benzine T ooth powder Cleaning 1. Clean the air filter by lightly tapping it or with the cleaner . It is more effective to clean the air filter with water . If the air filter is v ...

  • Haier AD122AMBHA - page 11

    10 "HOT KEEP"is operated in the following cases. When heating is started: In order to prevent blowing out of cool wind, the indoor unit fan stopped according to the room temperature which heating operation is started. W ait for approx. 2 to 3 minute, and the operation will be automatically changed to the ordinary heating mode. Defrosting ...

  • Haier AD122AMBHA - page 12

    1 1 For inspection and maintenance When you change your address or the installation place Electric work Confirm the following items for safe and comfortable use of air conditioner . The installation work is to be burden on the sales dealer , and do not conduct it by yourself. Installation place A void installing the air conditioner near the place w ...

  • Haier AD122AMBHA - page 13

    INST ALLA TION MANUAL FOR OUTDOOR UNIT Edging (2) Installation where the area with strong winds. Install the unit so that the air outlet section of the unit must NOT be faced toward wind direction. (1) Open space requirement around the unit 2. Selection of the place of installation 1. Accessories "Edging" for protection of electric wires ...

  • Haier AD122AMBHA - page 14

    13 INST ALLA TION MANUAL FOR OUTDOOR UNIT (1) Outline piping 4. Refrigerant piping (2) Piping size (3) Limitations for one way piping length and vertical height One way piping length: less than 15m. 90 + 0.5 Install the removed flared nuts to the pipes to be connected, then flare the pipes. Precautions for refrigerant piping Gas piping Liquid pipin ...

  • Haier AD122AMBHA - page 15

    14 INST ALLA TION MANUAL FOR OUTDOOR UNIT 7 90 for 6 sec. 4 (5) Purging method ( the refrigerant is R407C) If it does not stop gas leakage, discharge whole refrigerants from the serice port. After flaring work again and vacuumize, fill up prescribed refrigerant from the gas cylinder . Detach the charge hose from the service port, open 3-way valve a ...

  • Haier AD122AMBHA - page 16

    15 INST ALLA TION MANUAL FOR INDOOR UNIT 1. Safety precautions W ARNING Please read these "Safety Precautions" first then accurately execute the installation work. Though the precautionary points indicated herein are divided under two headings, and , those points which are related to the strong possibility of an installation done in error ...

  • Haier AD122AMBHA - page 17

    16 INST ALLA TION MANUAL FOR INDOOR UNIT NOTICE All Wiring of this installation must comply with NA TIONAL, ST A TE AND LOCAL REGULA TIONS . These instructions do not cover all variations for every kind of installation circumstance. Should further information be desired or should particular problems occur , the matter should be referred to your loc ...

  • Haier AD122AMBHA - page 18

    17 INST ALLA TION MANUAL FOR INDOOR UNIT (4) Preparation for suspending the unit There should be no obstacles within 250 (a) Figure of installation dimension: (unit: mm) When install the duct hidden type indoor unit, the return air box must be designed and installed, as Figure3, Figure4. The distance between the air outlet of duct and the air outle ...

  • Haier AD122AMBHA - page 19

    18 INST ALLA TION MANUAL FOR INDOOR UNIT 28 B C Air outlet grille T op panel of unit C amplified Use screw to fix top panel (Figure 6) B Air supply passage Rivet Unit M8 screw nut M8 wide expansion screw bolt (Figure 5) A amplified B amplified Air supply passage B M8 wide lock washer M8 hoisting screw Install the hoisting screw * Use M8 or M10 hois ...

  • Haier AD122AMBHA - page 20

    19 INST ALLA TION MANUAL FOR INDOOR UNIT Angle steel for support Hoisting screw Suspending bolt Requirements: The indoor side drain hose should be thermal insulated. The parts connected with indoor unit should be thermal insulated. Improper thermal insulation may cause dew-forming phenomenon. The drain hose should be downwards slant (over 1/100) an ...

  • Haier AD122AMBHA - page 21

    20 INST ALLA TION MANUAL FOR INDOOR UNIT Material of connection pipe and thermal insulation Foam polyethylene pipe, thickness over 10mm Stiff PVC pipe VP 20mm (inside diameter) Material of connection pipe Material of thermal insulation W arning ! Perform with two spanners Depenbing on the outdoor unit.For details,please refer to the operation manua ...

  • Haier AD122AMBHA - page 22

    21 INST ALLA TION MANUAL FOR ELECTRIC WIRING 1(L) Cautions: Use copper wire only .Parameters of connecting line : H05RN-F 4G0.75mm 2 Power supply :1PH,220-230V~,50Hz, connect from outside. Wiring methods: 1.Wiring method of ring terminal For connecting line which end is a ring,its wiring method as shown in the right figure: remove wiring screw and ...

  • Haier AD122AMBHA - page 23

    22 INST ALLA TION MANUAL FOR WIRE CONTROLLER 1.Remove the upper cover of wire contr oller The PC board is installed on the back cover of wire controller . When remove the upper cover , pay attention not to damage PC board. 2.Install wire contr oller ** Drill 2 wall holes according to the position of the 2 screw holes on the back * cover of wire con ...

  • Haier AD122AMBHA - page 24

    23 CHECK AND TEST RUN Other instruction 1. Set of the air sending of the fan motor Before leaving factory , the rotation speed of fan motor has already been set at standard choice. When the indoor unit uses free air sending and not needing to connect with duct, the fan speed of indoor unit is set at standard choice. When the indoor unit needs to co ...

Produzent Haier Kategorie Air Conditioner

Dokumente, die wir vom Produzenten des Geräts Haier AD122AMBHA erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Haier
- Bedienungsanleitungen AD122AMBHA
- Produktkarten Haier
- Informationsbroschüren
- oder Energieetiketten Haier AD122AMBHA
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Haier AD122AMBHA.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Haier AD122AMBHA, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Haier AD122AMBHA. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Haier AD122AMBHA ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Haier AD122AMBHA, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Haier AD122AMBHA hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Haier AD122AMBHA verständlich ist.

Eine gänzliche Bedienungsanleitung von Haier sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Haier AD122AMBHA bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Haier AD122AMBHA befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Haier AD122AMBHA, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Haier AD122AMBHA - die uns die ersten Schritte während der Nutzung von Haier AD122AMBHA erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Haier AD122AMBHA hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Haier AD122AMBHA im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Haier AD122AMBHA?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Haier AD122AMBHA nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Haier AD122AMBHA hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)