Bedienungsanleitung Studer Innotec RCC-02

51 Seiten 1.06 mb
Download

Zur Seite of 51

Summary
  • Studer Innotec RCC-02 - page 1

    Studer Innotec Rue des Casernes 57 CH - 1950 Sion Tel: +41 (0)27 205 60 80 Fax: +41 (0)27 205 60 88 E-mail: info@studer-innotec.com We b : www.studer-innotec.com V 2. 1 User Manual Remote control and programming unit RCC-02 and RCC-03 for the Xtender ...

  • Studer Innotec RCC-02 - page 2

    Studer Innotec 2 Reference This document applies to ve rsio ns of firmware V1.2.0 or higher of the remote control. Copyright Copyright © Studer Innote c. All rights reserved ...

  • Studer Innotec RCC-02 - page 3

    RCC 3 Table of contents Fore word ............................................................................................................................................................... 7 Conve ntio ns ............................................................................................................................................ ...

  • Studer Innotec RCC-02 - page 4

    Studer Innotec 4 Stop Inv erter o verv oltage ...................................................................................................... ...................... 2 5 Stop Overt empe ratu re ........................................................................................................... ...................... 25 Stop E xcessiv e ...

  • Studer Innotec RCC-02 - page 5

    RCC 5 Outp ut v oltage {128 6} .......................................................................................................... ................. 36 Level of battery und er-voltage at no load {1108} ............................................................................ 37 Acoust ic alarm o f the batt ery under -volt ag e {1196 } ... ...

  • Studer Innotec RCC-02 - page 6

    Studer Innotec 6 géné ral us e : Inv erte r, Cha rger with grid ...................................................................................... ............. 46 Use of a lim ite d power sourc e .................................................................................................. ................... 4 6 Use t o increase the pow ...

  • Studer Innotec RCC-02 - page 7

    RCC 7 FOREWORD This manual contains information rel ating to th e functioning of the RCC- 02 and RCC-03 remote controls. The use of certain functions sometimes requires in creased knowledge in various fields. This manual cann ot pro vid e th is. In c ase o f d oub t, p l ease contact your re seller or installer. C ONVENTIONS This symbol is used to ...

  • Studer Innotec RCC-02 - page 8

    Studer Innotec 8 S TUDER I NNOTEC CONTACT DETAILS Studer Innotec Rue des Casernes 5 7 CH – 1950 Sion Tel. +41 ( 0)27 205 60 80 Fax. +41 ( 0) 27 205 60 88 Customer service: info@studer-innotec.com After-sales service: sales@studer-innotec.com Technical support: support@studer-innotec.com Website: www.s tuder-innotec.com Y OUR RESELLER ’ CONTACT ...

  • Studer Innotec RCC-02 - page 9

    RCC 9 WARN INGS AN D CAUTIO N W ARRANTY Studer Innotec issues on this product, which they have manufactured and offered for sale, a two year warranty against any material defect or manu factur ing fault from the date of despatch by an agreed Studer Innotec distributor. Any warranty claim will be refused if it is not se nt back to the point of sale, ...

  • Studer Innotec RCC-02 - page 10

    Studer Innotec 10 Upd atin g m ust b e do ne in the f ull awa ren ess o f the c aus e a nd i s alw ay s th e re spo nsib ili ty o f th e customer. Par tial updates may cau se ruptures in th e compatibility or in its st ochastic operat ion. ...

  • Studer Innotec RCC-02 - page 11

    RCC 11 INTRODUCTION Congratulations! The purchas e of an RCC remote control offers you unlimited access to the various functions of the device s in the Xtend er series. Nu mero us configurations that can now be accessed allow you to o pti mise the o per atio n of the i nsta lla tion. De spi te al l the se o pti ons, the Xtend er w ork s on a simple ...

  • Studer Innotec RCC-02 - page 12

    Studer Innotec 12 CONNECTION The RCC-02 remo te con trol must be fir mly fasten ed using 3 screws on a flat support. The remote c o nt ro l RC C - 03 is m ea n t t o b e i nt eg r at ed . I t m u s t b e m o un t e d b y m ea n s of 4 s c re w s ( n o t s up p l ie d) on a flat place withou t any mechanical constrai n ts to the front p late. Once t ...

  • Studer Innotec RCC-02 - page 13

    RCC 13 DIMEN SIONS RCC-02 RCC-03 ...

  • Studer Innotec RCC-02 - page 14

    Studer Innotec 14 QUICK ST ART GUID E The remote control RCC gives you access to a many settings pos sibil ities. H oweve r, in most case s the setting of two parameters is required fo r the perfect running of your installation. A DJUSTMENT OF THE LANGUAGE To begin, set your remote control RCC for a display of the information in English. The basic ...

  • Studer Innotec RCC-02 - page 15

    RCC 15 You can now adapt your installatio n to the source which it is connected to. Max. current of the AC sour ce ( power-sharing) {1107}. In case of using the Xtender on a publ ic grid, it is actually the value of the circuit breaker on the source si d e (fuse or breaker). In a building, this value lies generally between 8 and 16A. In the case of ...

  • Studer Innotec RCC-02 - page 16

    Studer Innotec 16 A CTIVATION OF THE FUNCTIO N S MART -B OOST I f y o u r A C - I n s o u r c e i s l i m i t e d i n p o w e r , t h e Xtender can work as a support and add the missing power for your loads. First of all, check that you hav e adapted the Xtender t o your source (see previous chapt er: Ada p tation to t h e sourc e { 110 7} ) The ba ...

  • Studer Innotec RCC-02 - page 17

    RCC 17 BASI C DISPLAYS W h e n t h e r e m o t e c o n t r o l i s c o n n e c t e d t o a n X t e n d e r , i t i s p o s s i b l e t o a c c e s s d i f f e r e n t d i s p l a y menus divided into dist inct categories. Real time information displ ays on the operating mode of the installa ti on The history of events occu rring in the installation ...

  • Studer Innotec RCC-02 - page 18

    Studer Innotec 18 ACTIVATING AND DEACTIVA TING THE COMBI XTENDER W h e n o n e o f t h e d i s p l a y s i s v i s i b l e , i t i s p o s s i b l e t o a c t i v a t e o r d e a c t i v a t e t h e X t e n d e r . T o d o t h i s , simply press the key ES C. The key request on the screen indicates w hether you are going to activate or deactivate t ...

  • Studer Innotec RCC-02 - page 19

    RCC 19 ADJUSTMENT OF THE RCC REMOTE C ONTROL This screen gives you access to the remote control basic settings. From one of the basic menu i tems, use the keys UP a nd D OW N until r ea chi ng th e item “Ad jus tme nt o f th e remote control”, then co nfirm using the key SET. When the item to be modified appears on the screen, press t he key SE ...

  • Studer Innotec RCC-02 - page 20

    Studer Innotec 20 Duration of the back-lighting {5009} This configuration allows you t o determine after ho w muc h tim e of ina cti vity th e bac k-l igh ting wi ll switch off. Red back-lighting if the Xtender is OFF and if there is a fault {5026} If the Xtender is stopped by a fault (battery underv o ltage, overload, etc.) t he back-lighting flas ...

  • Studer Innotec RCC-02 - page 21

    RCC 21 programs. The file is writt en in a directory called STATS and in a subdirectory which indicates the date of backup . Backup of remote control configurations {5015} This function writes useful configurat ions for the operation of the remote control on to the SD card. Y o u c a n u s e t h i s f u n c t i o n t o d o a b a c k u p o f t h e r ...

  • Studer Innotec RCC-02 - page 22

    Studer Innotec 22 INFORM ATION O N TH E OPERAT IN G MOD E OF T H E INSTALL AT ION There are two different v iews for displa ying information on the syst em : A simplified and a configurable display. When one of these two displays is visible, it is possible to acti vate or dea cti vate th e sy st em. For fur the r information, please re fer to the p ...

  • Studer Innotec RCC-02 - page 23

    RCC 23 The following information is avail able: With regard to the grid input • AC In input voltage • AC In input current • AC In input power • Input frequency • Energy from AC-In of the previous day • Energy from AC-In of the current day With regard to the grid output • Output voltage • Output current • Output power • Output fr ...

  • Studer Innotec RCC-02 - page 24

    Studer Innotec 24 EVENT HISTORY This screen allows you to vi ew th e vari ous even ts tha t have occurred in t he installat ion. The events that occur in your inst allation are di splayed on the remote control screen. The events are classified within two categories: • The events tha t may have seri ous consequenc es are display ed up to the mo me ...

  • Studer Innotec RCC-02 - page 25

    RCC 25 E RROR I NCORRECT INPUT FREQUENCY The voltage at AC IN d oes not have a frequency includ ed in the admi ssible range for th e Xtender. Solution: When opera ting on a generator, check i ts speed. If you are n ot equiped to measure the gen erator fr equency, meas ure its voltage with no load. Indee d, if the voltage is correct , the frequency ...

  • Studer Innotec RCC-02 - page 26

    Studer Innotec 26 The voltage ripple on the batteries may be caused by thei r ageing. In this case, lower the charge current. M ESSAGE P OWER SHARING EXCE E DED ; TRANSFER PROHIBITED The power output of the consumers exceeds the one specified for the source, and the t ransfer relay can not be a c tivated . The Xten der ope rates in inv erte r mode. ...

  • Studer Innotec RCC-02 - page 27

    RCC 27 ADJUSTMENT OF THE COMBI XTENDE R G ENERAL The Xtender inverter/c harger has been designed to ensure that all basic fun ctions of an energy management system work completely independe ntly. In its original version, no adju stment is usua lly required. Neverthel ess, in certain inst allation condit ions, it may be ne cessary to adjust some ope ...

  • Studer Innotec RCC-02 - page 28

    Studer Innotec 28 According to the user level selected, it is possible t o access several hundred config urations. For this reason, each configuration has a unique ID displ ayed top right. I n the e ve nt o f qu esti ons on the sub jec t of a co nfi gur ati on, ensure that you have this number at hand. When you modify a configurat ion, a star is di ...

  • Studer Innotec RCC-02 - page 29

    RCC 29 Not e, that if the s mart b oos t f unc tio n is acti vated, it is po ssible to d is cha rge th e battery even if the inve rter function is locked. Authorised charger {1125} The battery charger f unction is ei ther activated or not. If this function is not authorised, it is necessary to charge the ba tteries using a source of energy not conn ...

  • Studer Innotec RCC-02 - page 30

    Studer Innotec 30 Number of critical battery under-vol tages before final stop {1305} and Leadtime to counting the critical battery under -voltages allowed before final stop {1405} The critical battery under- voltages can also be automatically acknowledged in case of undervoltage disap pearance. Like for the und er-voltages (see pr evious paragraph ...

  • Studer Innotec RCC-02 - page 31

    RCC 31 The bulk charge and f loating phases canno t be deactivated. If the conditions for starting a new battery charge cycle have co me together, th e bulk charge phase starts immediately. The battery cycle fi ts a large number of batteries by default, irrespectiv e of whether they are gel batteries or not. ...

  • Studer Innotec RCC-02 - page 32

    Studer Innotec 32 ...

  • Studer Innotec RCC-02 - page 33

    RCC 33 Charge current {1138} Use this value in order t o adapt the charge current to the battery . With this configura tion, the maximum current to be used for ch arging y our battery is ad justed. The curren t appropriate for the battery can be fou nd in its technical da ta. The valu e set by this configuration is used during the whole bulk charge ...

  • Studer Innotec RCC-02 - page 34

    Studer Innotec 34 Absorption phase {1451} During this phase, the battery accumu lates the fi nal percentages of the energy it is s toring. This phase is carried out with a constant volt age. Authorised absorption {1155} This configuration determines whet her or not th e absorpti on phase is used. If this phase is deactivated , the charger goes dire ...

  • Studer Innotec RCC-02 - page 35

    RCC 35 Equalization before absorption phase {1291} This configuration determines in the cha rge c ycle, in which equa liza tion will b e ac tivated, if the equalization is carried out after or before the absorption phase. The equalization phas e is carried out b ef o re the a bs o rp tio n ph ase by def aul t. A. Equalization B. Absorption C. Float ...

  • Studer Innotec RCC-02 - page 36

    Studer Innotec 36 End of equalization activated by the current {1168} The equalization phase can be interrupted if th e charge current of t he battery goe s under a cert ain thresh old. This can be use d to limit th e operating period of a genset while keeping an acceptable battery charge. During the equaliza tion phase, the char ge current decreas ...

  • Studer Innotec RCC-02 - page 37

    RCC 37 Level of battery under-voltage at no load {1108} Allows adj ustment of the batt ery’s low voltage level at which the inverter and smart boo st f unc tions ar e d eac tiv ate d. Thi s adjustment is ap plied in the case of a zero charge and is automatically adapted wi th regard to the power required f rom the batteries. This configuration is ...

  • Studer Innotec RCC-02 - page 38

    Studer Innotec 38 Delay before passing to inverter {1198} When the in put voltage is below th e transfer v oltage to th e inverter, the transfer relay d oes not open immediately . Wi th this configuration, the period during whic h the transfer r emains drawn ca n be specified. After this durat ion, the transfer relay is opened and the inv erter fun ...

  • Studer Innotec RCC-02 - page 39

    RCC 39 The auxiliary con tacts respond to vario us signal ty pes presen t ed graphica lly below. The f ol lowi ng typ es o f b asi c ev en ts ma y ac tiv ate the con ta cts: • Simple event • Scheduled event • Level In the followi ng descripti on, each pa rameter ha s two refere nce numb ers. The ref erence on the left relates to au xiliary co ...

  • Studer Innotec RCC-02 - page 40

    Studer Innotec 40 Limit the time of activation {1512} {1513} Maximum duration of ac tivation {1 514 } {1515} When the conditions ar e met, ei ther one or two relays are ac tivated perman ently. If you wish tha t the a cti vat io n dur ati on i s lim ited in ti me, even if the conditions are met , you can activate this func tion. O nce th e re lay i ...

  • Studer Innotec RCC-02 - page 41

    RCC 41 Inverter or smart boost overload {1228} {1336} Activates the contact in the event of an error due to exc essive power in the inverter or the Smart Boost function. In the event tha t the inver ter disconnec ts due to excess power and it is atte mpting to r e sta rt, the con tac t is n ot a cti va t ed u nti l th e en d of the a tt e mp ts. Ov ...

  • Studer Innotec RCC-02 - page 42

    Studer Innotec 42 The auxiliary contact will only be activated afte r the batte ry exceeds agai n a certain voltage value and also after a duration, both indepe nd ently o f the ac tiv ati on p ara me ters . This voltage and this duration are programmable too. • Dynamic compensation of th e thresholds { 1288} {1354} • Voltage 1 a ctive { 1246} ...

  • Studer Innotec RCC-02 - page 43

    RCC 43 o Time of end of activa tion {1273} {1382} • Program 2 {1274} {1383} o Days of the week { 1275} { 1384} o Time of start of acti va tion {1276} {1385} o Time of end of activa tion {1277} {1386} • Program 3 {1278} {1387} o Days of the week { 1279} { 1388} o Time of start of acti va tion {1280} {1389} o Time of end of activa tion {1281} {13 ...

  • Studer Innotec RCC-02 - page 44

    Studer Innotec 44 INFORM ATION O N THE S YSTE M The system inf o rmation allows y o u to check th e versions of the various elemen ts of your instal la tion. R EMOTE CONTROLS You will receive information on the hardware and software versions for each remote control. Furthermore, you have a ccess to its unique ID n umber. This uni que num ber is mar ...

  • Studer Innotec RCC-02 - page 45

    RCC 45 UPDATE S The RCC remo te control program as well as the code in the i nverters/ch argers of the X tender series can be updated in order t o integrate new features. For the RCC remote control it is also possibl e to implement new display languages (up to a maximum of 4 on each RCC remo te control). You ma y obt ain information about the avail ...

  • Studer Innotec RCC-02 - page 46

    Studer Innotec 46 APPLICATION EXAMPLES The examples b elow illustrate some imp lementation op tions for current install ations. Useful configurations for these situations are also given. These are common a nd non-obligatory configurations. For more details on each configuration shown, please refer to the complete description given above in this man ...

  • Studer Innotec RCC-02 - page 47

    RCC 47 U SE TO INCREASE THE POWER ON AN EXISTING INSTALLATION Description: The availability of an inv ert e r or a inverter/charge r allows its power to be extended with an Xtender connected in cascade. The m aximum power of the firs t inverter is li mited by the maximu m curren t from the transfer relay of the Xtender. Associated current configura ...

  • Studer Innotec RCC-02 - page 48

    Studer Innotec 48 ANNEXES A NNEXE 1 : L IST OF CONFIGURATION INTERDEPE NDENCIES N° Configuration N° Minimum li mit by N° Maximum limit by 1108 Underv oltage of the empty batt ery 1109 Under volt age of the charged battery 111 0 Rea cti vatio n volt ag e after battery undervol tage 1109 Underv oltage of the charged battery 1108 Under volt age of ...

  • Studer Innotec RCC-02 - page 49

    RCC 49 1308 Temperatu re at which the charge current begins to reduce 1115 Maximum operating temperatur e 1140 Battery maintenance voltage (floating) 1156 Battery absorption voltage 1152 Startup voltage of the timer before alarm 1156 Battery absorption voltage 1156 Battery absorption voltage 1140 Battery maintenance voltage (floating) 1164 Battery ...

  • Studer Innotec RCC-02 - page 50

    Studer Innotec 50 NOTES ...

  • Studer Innotec RCC-02 - page 51

    RCC ...

Produzent Studer Innotec Kategorie Universal Remote

Dokumente, die wir vom Produzenten des Geräts Studer Innotec RCC-02 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Studer Innotec
- Bedienungsanleitungen RCC-02
- Produktkarten Studer Innotec
- Informationsbroschüren
- oder Energieetiketten Studer Innotec RCC-02
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Studer Innotec RCC-02.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Studer Innotec RCC-02, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Studer Innotec RCC-02. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Studer Innotec RCC-02 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Studer Innotec RCC-02, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Studer Innotec RCC-02 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Studer Innotec RCC-02 verständlich ist.

Eine gänzliche Bedienungsanleitung von Studer Innotec sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Studer Innotec RCC-02 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Studer Innotec RCC-02 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Studer Innotec RCC-02, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Studer Innotec RCC-02 - die uns die ersten Schritte während der Nutzung von Studer Innotec RCC-02 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Studer Innotec RCC-02 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Studer Innotec RCC-02 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Studer Innotec RCC-02?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Studer Innotec RCC-02 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Studer Innotec RCC-02 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)