Bedienungsanleitung Ranger RCI-5054DX

11 Seiten 0.23 mb
Download

Zur Seite of 11

Summary
  • Ranger RCI-5054DX - page 1

    RCI-5054 DX AM/FM/SSB/CW 6 Meter Amateur Mobile Transceiver DIM NB/ANL MEM PRG SCAN SPLIT SWR R.BEEP MAN ENT LOCK SHF RCI−5054 DX CLR GAIN RF LSB FM USB AM OFF CW PA RF MIC PWR VOL SQ Owner's Manual - 1 - Table of Contents Chapter 1 Specifications ..………....................................... 2 Chapter 2 Introduction ................... ...

  • Ranger RCI-5054DX - page 2

    - 2 - Chapter 1 Specifications GENERAL Model RCI-5054DX Frequency Range : 50.000 ~ 54.000 MHz Tuning Steps 100 Hz, 1 KHz, 10 KHz, 100 KHz, 1 MHz Emission USB, LSB, CW, AM, FM Frequency Control Phase-Lock-Loop Synthesizer Frequency Tolerance 0.005% Frequency Stability 0.001% Operating Temper ature Range -10 O C to +50 O C Antenna Impedance 50 ohm Mi ...

  • Ranger RCI-5054DX - page 3

    - 4 - Chapter 3 Installation The RCI-5054DX is easy to install. All necessary parts (less the antenna and coax cable) have been included to facilitate installation. Transceiver Mounting Choose a suitable location for th e transceiver that will allow easy access to the front panel as well as proper air circulation to the back of the unit. If you are ...

  • Ranger RCI-5054DX - page 4

    - 6 - SWR DIM SCAN MEM LOCK ENT AM FM RCI−5054 DX MAN R.BEEP NB/ANL SPLI T PRG SHF CLR GAIN RF USB LSB CW OFF RF MIC PWR VOL PA SQ 9 24 15 10 11 16 17 12 18 13 14 19 20 21 21 6 7 8 35 24 23 22 1 Chapter 4 Operation Front Panel 1. FREQUENCY SELECTOR : Used to set the desired transmit and receive frequency. The frequency is digitally displayed in t ...

  • Ranger RCI-5054DX - page 5

    - 8 - special circumstances. We discourage use of this feature in normal operation, as it can be annoying to other operators. 11. SPLIT BUTTON (SPLIT) : Enables the offsetting of the transmitter frequency by up to +/- 2 Mhz (programmable) for FM repeater operation. 12. PROGRAM BUTTON (PRG) : Used to pre-program operating or scanning frequencies int ...

  • Ranger RCI-5054DX - page 6

    - 10 - 2 3 4 5 1 Operation (Continued) Rear Panel 1. ANTENNA : This jack accepts a 50 oh ms coaxial cable with a PL-259 style plug. 2. C W K E Y : The CW key is used for Morse Code operation. To operate connect a CW key to th is jack, and place the mode switch in the CW position. 3. EXTERNAL SPEAKER : This jack accepts a 4 - 8 ohm 5W external speak ...

  • Ranger RCI-5054DX - page 7

    - 12 - Operation (Continued) Frequency Selection Frequency selection in the RCI-5054DX can be accomplished using any one of the following three methods: 1. The first method of frequency selection uses the SHF (Shift) key and the ▲ (UP)/ ▼ (DOWN) keys located on the front panel . To accomplish this, press the SHF key until the display cursor on ...

  • Ranger RCI-5054DX - page 8

    - 14 - Chapter 5 Programming Receive Scanning The receive scanning feature helps locate active frequencies within a preprogrammed band segment anywhere on the 6 Meter band (refer to SCANNING, page 16). To begin scanning, slowly turn the Squelch control clockwise until the receiver noise disappears. Next, press the scan button. The unit should start ...

  • Ranger RCI-5054DX - page 9

    - 16 - . Chapter 6 Frequency Scanning Frequency scanning can be achieved by either of two methods: the first method involves scanning of all frequencies between a pre-set upper and lower scan frequency. The second method permits the scanning of frequencies previously programmed in the memory locations 0 thru 9. All-Frequency Scanning To allow All-F ...

  • Ranger RCI-5054DX - page 10

    - 18 - Chapter 7 Offset (Split) Frequency Operation The split frequency function offsets the transmitter frequency either above or below the receiver frequency by a user-programmable amount. This is necessary for op erating on FM repeaters. In the following example, the programmi ng of a 1 MHz offset will be described. Before attempting to program ...

  • Ranger RCI-5054DX - page 11

    - 20 - LIMITED WARRANTY Ranger Communications, I nc. ( Ranger ) warrants to the original purchaser ONLY this product against defects in material or workman ship as follows: 1 ) Ranger warrants the pro duct to be free of defects in material or workmanship (parts and labor on this product) for a period of two (2) ye ar from the original date of purch ...

Produzent Ranger Kategorie Marine Radio

Dokumente, die wir vom Produzenten des Geräts Ranger RCI-5054DX erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Ranger
- Bedienungsanleitungen RCI-5054DX
- Produktkarten Ranger
- Informationsbroschüren
- oder Energieetiketten Ranger RCI-5054DX
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Ranger RCI-5054DX.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Ranger RCI-5054DX, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Ranger RCI-5054DX. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Ranger RCI-5054DX ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Ranger RCI-5054DX, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Ranger RCI-5054DX hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Ranger RCI-5054DX verständlich ist.

Eine gänzliche Bedienungsanleitung von Ranger sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Ranger RCI-5054DX bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Ranger RCI-5054DX befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Ranger RCI-5054DX, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Ranger RCI-5054DX - die uns die ersten Schritte während der Nutzung von Ranger RCI-5054DX erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Ranger RCI-5054DX hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Ranger RCI-5054DX im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Ranger RCI-5054DX?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Ranger RCI-5054DX nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Ranger RCI-5054DX hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)