Bedienungsanleitung Kenmore POWER MISER 153.33066

32 Seiten 2.51 mb
Download

Zur Seite of 32

Summary
  • Kenmore POWER MISER 153.33066 - page 1

    1 Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A This water heater meets the new ANSI Z21.10.1 standard that deals with the accidental or unintended ignition of fl ammable vapors, such as those emitted by gasoline. Owner ’ s Manual FOR POT ABLE W A TER HEA TING ONL Y . NOT SUIT ABLE FOR SP ACE HEA TING. NOT FOR USE IN MOBILE HOMES. MODE ...

  • Kenmore POWER MISER 153.33066 - page 2

    2 SAFE INST ALLA TION, USE AND SER VICE Y our safety and the safety of others is extremely important in the installation, use and servicing of this water heater . Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential hazard. Read and obey all safety message ...

  • Kenmore POWER MISER 153.33066 - page 3

    3 SAFETY PRECAUTIONS ...

  • Kenmore POWER MISER 153.33066 - page 4

    4 T ABLE OF CONTENTS SAFE INST ALLA TION, USE AND SER VICE ...................................................................................................................... 2 SAFETY PRECAUTIONS .............................................................................................................................. 3 T ABLE OF CONTENTS ... ...

  • Kenmore POWER MISER 153.33066 - page 5

    5 Thank Y ou for purchasing a Kenmore water heater . Properly installed and maintained, it should give you years of trouble free service. If you should decide that you want the new water heater professionally installed by Sears, call 1-800-4-MY -HOME ® . They will arrange for prompt, quality installation by Sears authorized contractors. Abbreviati ...

  • Kenmore POWER MISER 153.33066 - page 6

    6 MA TERIALS AND BASIC TOOLS NEEDED Materials Needed T o simplify the installation, Sears has available the installation parts shown below . Y ou may or may not need all of these materials, depending on your type of installation. W A TER HEA TER INST ALLA TION KIT WITH FLEXIBLE CONNECTORS FOR 3/4” (19.05 mm) OR 1/2” (12.7 mm) THREADED OR COPPER ...

  • Kenmore POWER MISER 153.33066 - page 7

    7 A B C D E F G H I J X W V U T Y Q P F M N O S K L R 6” MAXIMUM AIR GAP DISCHARGE PIPE (Do not cap or plug) V ACUUM RELIEF VA LV E *INST ALL PER LOCAL CODES INST ALL THERMAL EXP ANSION T ANK OR DEVICE IF W A TER HEA TER IS INST ALLED IN A CLOSED W A TER SYSTEM TYPICAL INST ALLA TION GET TO KNOW YOUR W A TER HEA TER - GAS MODELS A V ent Pipe B Dr ...

  • Kenmore POWER MISER 153.33066 - page 8

    8 INST ALLA TION INSTRUCTIONS 1. T urn “OFF” the gas supply to the water heater . If the main gas line shutof f valve serving all gas appliances is used, also shut “OFF” the gas at each appliance. Leave all gas appliances shut “OFF” until the water heater installation is completed, see Figures 2 and 3. 2. T urn “OFF” the water suppl ...

  • Kenmore POWER MISER 153.33066 - page 9

    9 Facts to Consider About the Location Carefully choose an indoor location for the new water heater . The placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not for use in manufactured (mobile) homes or outdoor installation. Whether repla ...

  • Kenmore POWER MISER 153.33066 - page 10

    10 If this water heater will be used in beauty shops, barber shops, cleaning establishments, or self-service laundries with dry cleaning equipment, it is imperative that the water heater or water heaters be installed so that combustion and ventilation air be taken directly from outdoors (direct vent). Propellants of aerosol sprays and volatile comp ...

  • Kenmore POWER MISER 153.33066 - page 11

    11 • Do obtain new warning and instruction labels from Sears for placement on the blanket directly over the existing labels. • Do inspect the insulation blanket frequently to make certain it does not sag, thereby obstructing combustion air fl ow . Combustion Air and V entilation for Appliances Located in Uncon fi ned Spaces UNCONFINED SP ACE ...

  • Kenmore POWER MISER 153.33066 - page 12

    12 W ater Piping FIGURE 13. • Alternatively a single permanent opening may be used when communicating directly with the outdoors, or with spaces that freely communicate with the outdoors. The opening shall have a minimum free area of 1 square inch per 3,000 BTU per hour (8.3 cm²/kW) of total input rating of all equipment in the enclosure. See Fi ...

  • Kenmore POWER MISER 153.33066 - page 13

    13 This water heater shall not be connected to any heating systems or component(s) used with a non-potable water heating appliance. All piping components connected to this unit for space heating applications shall be suitable for use with potable water . T oxic chemicals, such as those used for boiler treatment shall not be introduced into this sys ...

  • Kenmore POWER MISER 153.33066 - page 14

    14 Fit T & P valve insulation over valve. Make sure that the insulation does not interfere with the lever of the T & P valve. Secure all insulation using tape. T emperature-Pressure Relief V alve The Discharge Pipe: • Shall not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or other restrictions. ...

  • Kenmore POWER MISER 153.33066 - page 15

    15 The temperature-pressure relief valve must be manually operated at least once a year . Caution should be taken to ensure that (1) no one is in front of or around the outlet of the temperature- pressure relief valve discharge line, and (2) the water manually discharged will not cause any bodily injury or property damage because the water may be e ...

  • Kenmore POWER MISER 153.33066 - page 16

    16 The vent pipe from the water heater must be no less than the diameter of the draft hood outlet on the water heater and must slope upward at least 1/4 inch per linear foot (21 mm per meter). See Figure 18. FIGURE 17. FIGURE 18. All vent gases must be completely vented to the outdoors of the structure (dwelling). Install only the draft hood provid ...

  • Kenmore POWER MISER 153.33066 - page 17

    17 W ater heaters covered in this manual have been tested and approved for installation at elevations up to 2,000 feet (610 m) above sea level. For installation above 2,000 feet (610 m), the water heater ’s Btu input should be reduced at the rate of 4 percent for each 1,000 feet (305 m) above sea level which requires replacement of the burner ori ...

  • Kenmore POWER MISER 153.33066 - page 18

    18 OPERA TING INSTRUCTIONS ...

  • Kenmore POWER MISER 153.33066 - page 19

    19 T emperature Regulation Due to the nature of the typical gas water heater , the water temperature in certain situations may vary up to 30F° (16.7 C°) higher or lower at the point of use such as, bathtubs, showers, sink, etc. HOTTER W A TER CAN SCALD: W ater heaters are intended to produce hot water . W ater heated to a temperature which will s ...

  • Kenmore POWER MISER 153.33066 - page 20

    20 T ank (Sediment) Cleaning Sediment build-up on the tank bottom may create varying amount of noise and if left in the tank will cause permanent tank failure. In some water areas, you may not be able to drain all sediment deposits by simply draining the tank. In these cases Mag-Erad (part no. 23600) can be used to help remove the sediment deposits ...

  • Kenmore POWER MISER 153.33066 - page 21

    21 Removing the Burner Door Assembly 1. T urn off the gas to the water heater at the manual gas shut-off valve (Figure 3). 2. T urn the gas control knob on the combination gas control valve/thermostat clockwise to the “OFF” position (Figure 1). NOTE: Depress the dial stop on Robertshaw valve before turning the gas control knob. See Lighting Ins ...

  • Kenmore POWER MISER 153.33066 - page 22

    22 Replacing the Thermocouple 1. Remove the Burner Door Assembly as directed previously . 2. Remove the retainer clip from the back of the two piece wire connector and remove the two piece wire connector from the assembly (Figure 27). 3. Pull the thermocouple from the pilot assembly (Figure 31). IMPORT ANT : Be careful not to bend or alter the posi ...

  • Kenmore POWER MISER 153.33066 - page 23

    23 Replacing the Burner Door Assembly 1. Check the door gasket for damage or imbedded debris prior to installation. 2. Inspect the viewport for damage and replace as required. 3. Insert the burner door assembly into the combustion chamber and slide it completely forward. Note: When inserting the burner door assembly , tip the burner end up slightly ...

  • Kenmore POWER MISER 153.33066 - page 24

    24 Removing and Replacing the Gas Control V alve/Thermostat IMPORT ANT : The gas control valve/thermostat is a standard valve with a right-hand thread thermocouple. Use only factory authorized replacement parts. Removing the Gas Control V alve/Thermostat: 1. T urn the gas control knob on the combination gas control valve/thermostat clockwise to the ...

  • Kenmore POWER MISER 153.33066 - page 25

    25 or replaced more often than an anode rod that appears to be intact. Replacement of a depleted anode rod can extend the life of your water heater . Inspection should be conducted by calling the Sears Service Center for an authorized contractor . At a minimum, the anode(s) should be checked annually after the warranty period. T emperature-Pressure ...

  • Kenmore POWER MISER 153.33066 - page 26

    26 TROUBLESHOOTING GUIDE Start Up Conditions Thermal Expansion As water is heated, it expands (thermal expansion). In a closed system, the volume of water will grow . As the volume of water grows, there will be a corresponding increase in water pressure due to thermal expansion. Thermal expansion can cause premature tank failure (leakage). This typ ...

  • Kenmore POWER MISER 153.33066 - page 27

    27 Condensation Whenever the water heater is fi lled with cold water , some condensate will form while the burner is on. A water heater may appear to be leaking when in fact the water is condensation. This usually happens when: • A new water heater is fi lled with cold water for the fi rst time. • Burning gas produces water vapor In water he ...

  • Kenmore POWER MISER 153.33066 - page 28

    28 PROBLEM POSSIBLE CAUSE(S) CORRECTIVE ACTION BURNER WILL NOT IGNITE 1. Pilot not lit 2. Thermostat set too low 3. No gas 4. Dirt in the gas lines 5. Pilot line clogged 6. Main burner line clogged 7. Non-functioning thermocouple 8. Non-functioning thermostat 9. Heater installed in a confined area 1. Light pilot 2. T urn temp. dial to desired tempe ...

  • Kenmore POWER MISER 153.33066 - page 29

    29 PROBLEM POSSIBLE CAUSE(S) CORRECTIVE ACTION DRIP FROM RELIEF V AL VE 1. Excessive water pressure 2. Closed water system 1. Use a pressure reducing valve and relief valve 2. See “Thermal Expansion” THERMOST A T F AILS TO SHUT OFF 1. Non-functioning thermostat 2. Improper calibration 1. Replace thermostat 2. Replace thermostat COMBUSTION ODORS ...

  • Kenmore POWER MISER 153.33066 - page 30

    30 Have you bled all the air from the pilot tube and gas supply line? NO While repeatedly depressing the igniter button, hold down the reset button until the pilot is lit and maintains a stable flame, then slowly release the reset button. YES Section A: Pilot light will not light. Section B: Pilot light will not remain lit or repeatedly goes out. C ...

  • Kenmore POWER MISER 153.33066 - page 31

    31 Now that you have purchased your gas water heater , should a need ever exist for repair parts or service, simply contact any Sears Service Center or call 1-800-4-MY -HOME ® (1-800-469-4663). Be sure to provide all pertinent facts when you call or visit. WHEN ORDERING REP AIR P ARTS, AL W A YS GIVE THE FOLLOWING INFORMA TION: • MODEL NUMBER ? ...

  • Kenmore POWER MISER 153.33066 - page 32

    32 6 - YEAR LIMITED W ARRANTY ON W A TER HEA TER For six years from the date of purchase, if this water heater is installed and operated in a single-family home in accordance w ith the owner ’s manual instructions and all local applicable plumbing codes, Sears will: • Supply free water heater parts for those that are defective in material or wo ...

Produzent Kenmore Kategorie Water Heater

Dokumente, die wir vom Produzenten des Geräts Kenmore POWER MISER 153.33066 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Kenmore
- Bedienungsanleitungen POWER MISER 153.33066
- Produktkarten Kenmore
- Informationsbroschüren
- oder Energieetiketten Kenmore POWER MISER 153.33066
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Kenmore POWER MISER 153.33066.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Kenmore POWER MISER 153.33066, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Kenmore POWER MISER 153.33066. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Kenmore POWER MISER 153.33066 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Kenmore POWER MISER 153.33066, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Kenmore POWER MISER 153.33066 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Kenmore POWER MISER 153.33066 verständlich ist.

Eine gänzliche Bedienungsanleitung von Kenmore sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Kenmore POWER MISER 153.33066 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Kenmore POWER MISER 153.33066 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Kenmore POWER MISER 153.33066, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Kenmore POWER MISER 153.33066 - die uns die ersten Schritte während der Nutzung von Kenmore POWER MISER 153.33066 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Kenmore POWER MISER 153.33066 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Kenmore POWER MISER 153.33066 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Kenmore POWER MISER 153.33066?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Kenmore POWER MISER 153.33066 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Kenmore POWER MISER 153.33066 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)