Summary
  • York CU060 - 300 - page 1

    FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 271846-YTG-B-0208 ® MODELS: CH060 - 5-10 TONS HORIZONT AL MODELS: CU060 - 300 5-25 TONS VERTI CAL SINGLE P ACKAGE AIR CONDITIONING WA T E R C O O L E D ...

  • York CU060 - 300 - page 2

    271846-YTG-B-0208 2 Johnson Controls Unitary Products TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 APPLICATION FLEXIBILITY . . . . . . . . . . . . . . . . . . . 3 CABINET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 REFRIGERATION CIRCUITS . . . . . . . . . . . . . . . . . . 3 I ...

  • York CU060 - 300 - page 3

    271846-YTG-B-0208 Johnson Controls Unitary Products 3 DESCRIPTION These units are completely asse mbled, piped, wired, charge d and tested at the factory and are shipped ready for immedia te installation. Only the power supply wiring, the thermostat wir - ing, the condenser water piping, the conde nsate drain piping and the ductwork are required to ...

  • York CU060 - 300 - page 4

    271846-YTG-B-0208 4 Johnson Controls Unitary Products FACTORY INST ALLED OVERSIZED EVAPORATOR FAN MOTORS Increased horsepow er motors and drive components are available for those applicatio ns where external static pres - sure requirements exceed the capability of the standard motor . CORROSION RESISTANT COATINGS Evaporator coil shall receive a 1-m ...

  • York CU060 - 300 - page 5

    271846-YTG-B-0208 Johnson Controls Unitary Products 5 NOTE: Cooling performance is ra te d at 80°F dry bulb 67°F wet bulb entering air temperatu re, CFM listed, 85°F enterin g 95°F leaving water temperature, and water flow rate list ed. Gross capacity does not include the effect of evapora - tor fan motor heat. T ABLE 1: GENERAL DA T A - CH060- ...

  • York CU060 - 300 - page 6

    271846-YTG-B-0208 6 Johnson Controls Unitary Products NOTE: Cooling performance is ra ted at 80°F dry bulb 67°F wet bulb entering a ir temperature, CFM listed, 85°F entering 95°F leaving water temperature, and water flow rate list ed. Gross capacity does not include the effect of evapora - tor fan motor heat. T ABLE 2: GENERAL DA T A CU 5-25 T ...

  • York CU060 - 300 - page 7

    271846-YTG-B-0208 Johnson Controls Unitary Products 7 NOTE: 1. At higher evaporator airflows, and wet bulb conditions condensate ca rry -over may occur. Adjust airflow downward as necessar y. 2. Values include pressure drop from wet coil and cle an filters. 3. Shaded areas indicate oversize motors. T ABLE 3: SUPPLY AIR BLOWER PERFORMANCE CH 060-120 ...

  • York CU060 - 300 - page 8

    271846-YTG-B-0208 8 Johnson Controls Unitary Products NOTE: At higher evaporator airf lows and wet bu lb conditions, condensate carry-over may occu r . Adjust airflow downwa rd as necessary V alues include pressure drop from wet coil and clean filter s. Shaded areas indicate oversize motors. NOTE: At higher evaporator airf lows and wet bu lb condit ...

  • York CU060 - 300 - page 9

    271846-YTG-B-0208 Johnson Controls Unitary Products 9 T ABLE 6: W ATERSIDE PRESSURE DROP - CU MODELS CU060 CU096 CU120 CU180 CU240 CU300 ...

  • York CU060 - 300 - page 10

    271846-YTG-B-0208 10 Johnson Controls Unitary Products T ABLE 7: WATER PRESSURE DROP DAT A - CH MODELS ...

  • York CU060 - 300 - page 11

    271846-YTG-B-0208 Johnson Controls Unitary Products 11 T ABLE 8: COOLING PER FORMANCE DA T A - CH 5-10 TON HORIZONT A L MODELS CH060 5 TON 2000 CFM 9 GPM 15 GPM EWT EWT 65°F 85°F 105°F 65°F 85°F 10 5°F EWB EDB TC SC kW TC SC kW TC SC kW TC SC kW TC SC kW TC SC kW 62°F 75°F 63.2 48.3 2.88 59.7 54.5 3.66 55.1 44.0 4.67 64.0 48. 7 2.72 60.5 46 ...

  • York CU060 - 300 - page 12

    271846-YTG-B-0208 12 Johnson Controls Unitary Products T ABLE 9: COOLING PER FORMANCE DA T A - CU 5-20 TON VERTICAL MODELS CU060 5 TON 2000 CFM 9 GPM 15 GPM EWT EWT 65°F 85°F 105°F 65°F 85°F 105°F EWB EDB TC SC kW TC SC kW TC SC kW TC SC kW TC SC kW TC SC kW 62°F 75°F 62.1 48 .9 2.87 58.3 47.2 3.65 54.4 45.4 4.67 63.1 49.4 2.71 59.2 47.5 3. ...

  • York CU060 - 300 - page 13

    271846-YTG-B-0208 Johnson Controls Unitary Products 13 T ABLE 10: COOLING PERFORMANCE DATA - CU 25 TON VERTICAL MODELS T ABLE 1 1: WATER-SIDE ECONOMIZER COOL ING PERFORMANCE DATA - CH 5-10 TON MODELS CU300 25 TON 10000 CFM 45 GPM 75 GPM EWT EWT 65°F 85°F 105°F 65°F 85°F 105°F EWB EDB TC SC kW TC SC kW TC SC kW TC SC kW TC SC kW TC SC kW 62°F ...

  • York CU060 - 300 - page 14

    271846-YTG-B-0208 14 Johnson Controls Unitary Products T ABLE 13: STANDARD MOTORS CU 5-25 TON MODELS T ABLE 12: WA TER-SIDE ECONOMIZER CO OLIN G PERFORMA NCE DATA - CU 5-25 TON VERTICAL MODELS UNIT Air @ 80°F EDB, 67°F EWB Wa t e r Capacity [MBH] CFM PD [in WG] Flow [GPM] PD [PSI] EWT [°F] To t a l Sensible CU060 2000 0.28 9 1.5 45 48.4 38.9 55 ...

  • York CU060 - 300 - page 15

    271846-YTG-B-0208 Johnson Controls Unitary Products 15 T ABLE 14: OVERSIZED MOTORS CU 5- 25 TON MODELS T ABLE 15: ST ANDARD MOTORS CH 5-10 TON MODELS T ABLE 16: OVERSIZED MOT ORS CH 8-10 TON MO DEL S MODEL# VOL T AGE COMPRESSOR EV AP ORA TOR F AN MIN. CCT . AMP ACITY MAX FUSE / CCT . BKR. AMP QTY RLA LRA HP FLA RPM CU060 208-230/3/60 1 @ 19.3 123.0 ...

  • York CU060 - 300 - page 16

    271846-YTG-B-0208 16 Johnson Controls Unitary Products FIGURE 1 - DIMENSIONAL DATA - CH 5 TON HORIZONTAL MODEL ...

  • York CU060 - 300 - page 17

    271846-YTG-B-0208 Johnson Controls Unitary Products 17 FIGURE 2 - DIMENSIONAL DATA - CH 8 & 10 TON HORIZONTAL MODELS ...

  • York CU060 - 300 - page 18

    271846-YTG-B-0208 18 Johnson Controls Unitary Products FIGURE 3 - PHYSICAL CONFIGURATION DAT A - CH 8 & 10 TON WATER SIDE ECONOMIZER Economizer Coil Filter Frame Electrical Connections 10 12 Water Side View 2-3/4 6-1/2 Water Out Condensate ...

  • York CU060 - 300 - page 19

    271846-YTG-B-0208 Johnson Controls Unitary Products 19 T ABLE 17: DIMENSIONAL D AT A - CU 5, 8, AND 10 TON VERTICAL MODELS FIGURE 4 - DIMENSIONAL DATA - CU 5, 8, AND 10 TON VERTICAL MODELS W A TER OUT W A TER IN CONDENSA TE DRAIN COMPRESSOR/CONDENSER ACCESS G C F 0.63" A B E ELECTRICAL P ANEL F AN MOTOR ACCESS FIL TER ACCESS COIL FIL TER DRAIN ...

  • York CU060 - 300 - page 20

    271846-YTG-B-0208 20 Johnson Controls Unitary Products FIGURE 5 - DIMENSIONAL DATA - CU 15 TON VERTICAL MODEL 2.63” 15.88” Allow 36” minimum clearance Allow 24” minimum clearance Allow 24” minimum clearance 18.25” 12.88” 12.88” 18.50” ...

  • York CU060 - 300 - page 21

    271846-YTG-B-0208 Johnson Controls Unitary Products 21 FIGURE 6 - DIMENSIONAL DATA - CU 20 TON VERTICAL MODEL ...

  • York CU060 - 300 - page 22

    271846-YTG-B-0208 22 Johnson Controls Unitary Products FIGURE 7 - DIMENSIONAL DATA - CU 25 TON VERTICAL MODEL ...

  • York CU060 - 300 - page 23

    271846-YTG-B-0208 Johnson Controls Unitary Products 23 SUPPLY AIR/RETURN AIR CONFIGURATION All models are field convertible for multiple supp ly return con - figurations. The 5 throu gh 15 ton model s feature a removabl e upper fan module that can be rotated 180° for top rear dis - charge applications. In addition, the blower outlet panel may be i ...

  • York CU060 - 300 - page 24

    271846-YTG-B-0208 24 Johnson Controls Unitary Products FIGURE 9 - HOT W A TER & STEAM HEA TING COILS DIMENSIONAL DA T A Hot W ater and Steam Heating Coil Dimens ions (Inches) Unit Model A B C Inlet (MPT Outle t (MP T) CU060 37.50 5.50 23 1 1/2 1 1/2 CU096 59.50 5.50 28 1 1/2 1 1/2 CU120 59.50 5.50 28 1 1/2 1 1/2 CU180 71.50 5.50 33 2 2 CU240 76 ...

  • York CU060 - 300 - page 25

    271846-YTG-B-0208 Johnson Controls Unitary Products 25 FIGURE 10 - HOT W A TER & STEAM HE A TING COILS PER FORMANCE DA T A CU240 - 300 CU060 - 180 Steam Coil Performance @ 2 PSIG • S team Heating Coils are tube -in-tube ‘steam distributing ’ typ e to eliminate risk of con- densate freezing. • Coils are con structed of 5/8 inch diameter ...

  • York CU060 - 300 - page 26

    271846-YTG-B-0208 26 Johnson Controls Unitary Products FIGURE 1 1 - TYPICAL W A TER-SIDE ECONOMIZER PHYSICAL CONFIGURA TION ...

  • York CU060 - 300 - page 27

    271846-YTG-B-0208 Johnson Controls Unitary Products 27 FIGURE 12 - TYPICAL W A TER-S IDE ECONOMIZER PIPING SCHEMA TIC ...

  • York CU060 - 300 - page 28

    Subject to change without notice. Print ed in U. S.A. 271846-YTG-B-0208 Copyright © 2008 by Johnson Controls, Inc. All rights reserved . Supersedes: 271846- YTG-A-0906 Johnson Contro ls Unitary Products 5005 York Drive Norman, OK 73069 FIGURE 13 - TYPICAL W A TER-SIDE ECONOMIZER CONTROL - 15-20 T ON VERTICAL (208-23 0 V/3PH/60HZ) ...

Produzent York Kategorie Air Conditioner

Dokumente, die wir vom Produzenten des Geräts York CU060 - 300 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen York
- Bedienungsanleitungen CU060 - 300
- Produktkarten York
- Informationsbroschüren
- oder Energieetiketten York CU060 - 300
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung York CU060 - 300.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen York CU060 - 300, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen York CU060 - 300. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts York CU060 - 300 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts York CU060 - 300, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von York CU060 - 300 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von York CU060 - 300 verständlich ist.

Eine gänzliche Bedienungsanleitung von York sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von York CU060 - 300 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von York CU060 - 300 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich York CU060 - 300, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts York CU060 - 300 - die uns die ersten Schritte während der Nutzung von York CU060 - 300 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit York CU060 - 300 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von York CU060 - 300 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich York CU060 - 300?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit York CU060 - 300 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit York CU060 - 300 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)