Bedienungsanleitung Miller Electric Regency 250

28 Seiten 0.7 mb
Download

Zur Seite of 28

Summary
  • Miller Electric Regency 250 - page 1

    Regency 250 Processes Description R MIG (GMA W) W elding Arc Welding Power Source OM-293 120 243N October 2001 Visit our website at www.MillerWelds.com ...

  • Miller Electric Regency 250 - page 2

    Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual catalog sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .MillerW eld ...

  • Miller Electric Regency 250 - page 3

    T ABLE OF CONTENTS SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2. Arc Welding Hazards 1 . . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric Regency 250 - page 4

    ...

  • Miller Electric Regency 250 - page 5

    OM-293 Page 1 SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING som _nd_4/98 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. Y Marks a special safety message. . Means “Note”; not safety related. This group of symbols means W arning! W atch ...

  • Miller Electric Regency 250 - page 6

    OM-293 Page 2 Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld. ARC RA YS can burn eyes and skin. D Wear a welding helmet fitted with a proper shade of filter to protect your face and eyes when welding or watching (see ANSI Z49.1 and Z87 ...

  • Miller Electric Regency 250 - page 7

    OM-293 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring – be sure power supply system is properly sized, rated, and protected to handle this unit. F A ...

  • Miller Electric Regency 250 - page 8

    OM-293 Page 4 1-5. EMF Information Considerations About W elding And The Effects Of Low Frequency Electric A n d M a g netic Fields W elding current, as it flows through welding cables, will cause electro- magnetic fields. There has been and still is some concern about such fields. However , after examining more than 500 studies spanning 17 years o ...

  • Miller Electric Regency 250 - page 9

    OM-293 Page 5 SECTION 1 – CONSIGNES DE SECURITE – LIRE A V ANT UTILISA TION som _nd_fre 4/98 1-1. Signification des symboles Signifie Mise en garde ! Soyez vigilant ! Cette proc é dure pr é sente des risques de danger ! Ceux-ci sont identifi é s par des symboles adjacents aux directives. Y Identifie un message de s é curit é particulier . ...

  • Miller Electric Regency 250 - page 10

    OM-293 Page 6 Le rayonnement de l ’ arc du proc é d é de soudage g é n è re des rayons visibles et invisibles intenses (ultraviolets et infrarouges) susceptibles de provoquer des br û lures dans les yeux et sur la peau. Des é tincelles sont projet é es pendant le soudage. LES RA YONS DE L ’ ARC peuvent pro- voquer des br û lures dans le ...

  • Miller Electric Regency 250 - page 11

    OM-293 Page 7 1-3. Dangers suppl é mentaires en relation avec l ’ installation, le fonctionnement et la maintenance Risque D ’ INCENDIE OU D ’ EXPLOSION. D Ne pas placer l ’ appareil sur , au-dessus ou à proxi- mit é de surfaces infllammables. D Ne pas installer l ’ appareil à proximit é de produits inflammables D Ne pas surcharger l ...

  • Miller Electric Regency 250 - page 12

    OM-293 Page 8 1-4. Principales normes de s é curit é Safety in W elding and Cutting, norme ANSI Z49.1, de l ’ American Wel- ding Society , 550 N.W . Lejeune Rd, Miami FL 33126 Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent of Documents, U.S. Government Printing Of fice, Washington, D.C. 20402. Recommended Safe Practice for the ...

  • Miller Electric Regency 250 - page 13

    OM-293 Page 9 SECTION 2 – INST ALLA TION 2-1. Specifications Rated W elding V oltage Range Maximum Open- Amperes Input at Rated Load Output, 60 Hz, Single-Phase Output DC Circuit V oltage DC 200 V 230 V 460 V KV A KW 200 A @ 2 8 V olts DC, 60% Duty Cycle Low Range: 10 – 20 V; High Range: 20 – 30 V 42 46 (1.2*) 40 (1.0*) 20 (0.5*) 9.2 (0.2*) 8 ...

  • Miller Electric Regency 250 - page 14

    OM-293 Page 10 2-3. V olt-Ampere Curves va_curve1 4/95 – 049 424-E V olt-ampere curves show mini- mum and maximum voltage and amperage output capabilities of unit. Curves of other settings fall be- tween curves shown. 2-4. Selecting A Location 1 Lifting Forks Use lifting forks to move unit. Extend forks beyond opposite side of unit. 2 Rating Labe ...

  • Miller Electric Regency 250 - page 15

    OM-293 Page 1 1 2-5. Dimensions And Weights Dimensions Height 23-1/4 in (591 mm) C H 8 Holes Width 16 in (406 mm) Depth 22-3/4 in (578 mm) A 13 in (330 mm) A B 12-1/4 in (31 1 mm) B C 3/4 in (19 mm) Front D 16-1/16 in (408 mm) E 14-29/32 in (379 mm) F 15-13/32 in (137 mm) G G 13/32 in (10 mm) E F H 7/16 (1 1 mm) Dia 155 897-A D W eight 168 lb (76 k ...

  • Miller Electric Regency 250 - page 16

    OM-293 Page 12 2-7. Remote 14 Receptacle Information AJ K I Socket* Socket Information B K I C L NH D M G 24 VOL TS AC A 24 volts ac. Protected by circuit breaker CB2. E F 24 VOL TS AC B Contact closure to A completes 24 volts ac con- tactor control circuit. 1 15 VOL TS AC I 1 15 volts ac. Protected by circuit breaker CB1. 1 15 VOL TS AC J Contact ...

  • Miller Electric Regency 250 - page 17

    OM-293 Page 13 2-9. Placing Jumper Links And Connecting Input Power S-0279-B / Ref. 121 471-H Check input voltage available at site. 1 Jumper Link Label 2 Jumper Link Move jumper links to match input power . 3 Line Disconnect Device Select type and size of overcurrent protection using Section 2-8. Rat- ings must comply with applicable codes. Instal ...

  • Miller Electric Regency 250 - page 18

    OM-293 Page 14 SECTION 3 – OPERA TION 3-1. Controls 1 V oltage Range Switch Use switch to select voltage range. 2 V oltage Adjustment Switch Us e switch to adjust voltage within range se- lected by V oltage Range switch. Each posi- tion of the switch is a change of 2 volts. Y Do not change position of V oltage Range switch or V oltage Adjustment ...

  • Miller Electric Regency 250 - page 19

    OM-293 Page 15 SECTION 4 – MAINTENANCE & TROUBLESHOOTING 4-1. Routine Maintenance Y Disconnect power before maintaining. 3 Months Replace Unreadable Labels Repair Or Replace Cracked W eld Cable Replace Cracked Parts 14-Pin Cord T orch, Electrode Holder , Or Gun Cable Clean And T ighten W eld T erminals 6 Months Blow O u t Or V acuum Inside Du ...

  • Miller Electric Regency 250 - page 20

    OM-293 Page 16 SECTION 5 – ELECTRICAL DIAGRAM 192 974 Figure 5-1. Circuit Diagram For Welding Power Source ...

  • Miller Electric Regency 250 - page 21

    OM-293 Page 17 SECTION 6 – P ARTS LIST 121 583-H . Hardware is common and not available unless listed. 1 2 3 4 5 6 7 – (Fig 6 – 3) 8 (Fig 6 – 2) – 19 20 9 10 11 12 13 14 15 16 17 18 Figure 6-1. Main Assembly Description Part No. Dia. Mkgs. Item No. Figure 6-1. Main Assembly Quantity 1 +047 167 WRAPPER 1 . . . . . . . . . . . . . . . . . . ...

  • Miller Electric Regency 250 - page 22

    OM-293 Page 18 . Hardware is common and not available unless listed. 121 587-G 1 2 3 6 7 8 9 10 11 12 11 13 14 4 5 15 Figure 6-2. Panel, Front w/Components ...

  • Miller Electric Regency 250 - page 23

    OM-293 Page 19 Description Part No. Dia. Mkgs. Item No. Figure 6-2. Panel, Front w/Components (Fig 6-1 Item 19) Quantity 1 206 444 LABEL, nameplate 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 192 973 P ANEL, front 1 . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric Regency 250 - page 24

    OM-293 Page 20 Description Part No. Dia. Mkgs. Item No. Figure 6-3. Panel, Rear w/Components (Fig 6-1 Item 7) Quantity 1 081 372 BLADE, fan 9 in 5wg 20deg 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 172 529 P ANEL, rear 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric Regency 250 - page 25

    ...

  • Miller Electric Regency 250 - page 26

    ...

  • Miller Electric Regency 250 - page 27

    Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 7/00 Y o ur distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor . The expertise ...

  • Miller Electric Regency 250 - page 28

    PRINTED IN USA  2002 Miller Electric Mfg. Co. 1/02 Miller Elect ric Mfg. Co. An I l li noi s T ool Works Com pany 1635 W est S pencer St reet Applet on, WI 54914 USA International He adquarters – USA USA Phone: 920-735-4505 Auto-A t t ended USA & Canada F AX : 920-735-4134 Int ernati onal FAX: 920-735-4125 European Headqua rters – United ...

Produzent Miller Electric Kategorie Welding System

Dokumente, die wir vom Produzenten des Geräts Miller Electric Regency 250 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Miller Electric
- Bedienungsanleitungen Regency 250
- Produktkarten Miller Electric
- Informationsbroschüren
- oder Energieetiketten Miller Electric Regency 250
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Miller Electric Regency 250.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Miller Electric Regency 250, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Miller Electric Regency 250. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Miller Electric Regency 250 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Miller Electric Regency 250, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Miller Electric Regency 250 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Miller Electric Regency 250 verständlich ist.

Eine gänzliche Bedienungsanleitung von Miller Electric sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Miller Electric Regency 250 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Miller Electric Regency 250 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Miller Electric Regency 250, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Miller Electric Regency 250 - die uns die ersten Schritte während der Nutzung von Miller Electric Regency 250 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Miller Electric Regency 250 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Miller Electric Regency 250 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Miller Electric Regency 250?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Miller Electric Regency 250 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Miller Electric Regency 250 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)