Bedienungsanleitung RIDGID OL50145MW

20 Seiten 2.3 mb
Download

Zur Seite of 20

Summary
  • RIDGID OL50145MW - page 1

    1 Y our air compressor has been engineer ed and manufactured to our high standar d for dependability , ease of operation, and operator safety . When properly car ed for , it will give you years of rugged, trouble-fr ee performance. WARNING: T o reduce the risk of injury , the user must read and understand the operator’ s manual before using this ...

  • RIDGID OL50145MW - page 2

    2  Introduction....................................................................................................................................................................... 2  General Safety Rules ................................................................................................................................... ...

  • RIDGID OL50145MW - page 3

    3 GENERAL SAFETY RULES WARNING: Read and understand all instructions. Failure to follow all instructions listed below may r esult in electric shock, fir e, and/or serious personal injury . SA VE THESE INSTRUCTIONS WORK AREA  Keep your work area clean and well lit. C lu tte red benches and dark areas invite accidents. Floor must not be slipper ...

  • RIDGID OL50145MW - page 4

    4  Kno w your po wer to ol. Re ad oper ato r’ s ma nua l car efu lly . Learn its applications and limitations, as well as the specific potential hazar ds related to this tool. Following this rule will reduce the risk of electric shock, fire, or serious injury .  Drain tanks of moisture after each day’ s use. If unit will not be used ...

  • RIDGID OL50145MW - page 5

    5 SYMBOLS Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper inter - pretation of these symbols will allow you to operate the pr oduct better and safer . Read The Operator’ s Manual Risk of Bursting Risk of Fire or Explosion SYMBOL NAME DESIGNA TION/EXPLANA TION V oltage Current Frequency ...

  • RIDGID OL50145MW - page 6

    6 SYMBOLS SERVICE Servicing requires extr eme care and knowledge and should be performed only by a qualified service technician. For service we suggest you return the product to your near est AUTHORIZED SERVICE CENTER for repair . When servic- ing, use only identical replacement parts. WARNING: T o avoid serious personal injury , do not attempt to ...

  • RIDGID OL50145MW - page 7

    7 EXTENSION CORDS Use only 3-wire extension cords that have 3-prong ground- ing plugs and 3-pole r eceptacles that accept the product’ s plug. When using a power tool at a considerable distance fr om the power sour ce, use an extensio n cor d he avy en ough to carry the current that the tool will draw . An undersized extension cor d will cause a ...

  • RIDGID OL50145MW - page 8

    8 GLOSSAR Y OF TERMS Pressur e Regulator Knob Regulates the outgoing pressure from the air outlet to the tool. It is possible to increase or decrease the pressure at the outlet by adjusting this control knob. Pressur e Switch Automatically controls the on/off cycling of the compressor . It stops the compr ess or wh en the cu t-of f pres sur e in th ...

  • RIDGID OL50145MW - page 9

    9 0 0 2 4 50 100 150 230 200 bar 100 0 0 16 5 50 150 200 230 bar psi ON OFF O I 1 TM 2 MINI WHEELBARROW COMPRESSOR OIL LUBE PUMP - POMPE A HULE - BOMBA CON LUBRICACION DE ACI ETE 5 Gallon 18,8 Litre 18,7 Litro 4.4 SCFM @ 90PSI 0,12 m /Min @ 621 kPa 0,12 m /Min @ 6,21 bar 145 Max PSI 999 KpA 9,99 bar 3 3 T A N Q U E - T A N K - R E S E V I O R E N C ...

  • RIDGID OL50145MW - page 10

    10 0 2 4 6 40 80 120 160 bar 0 2 4 6 40 80 120 160 bar ON OFF O I 1 TM 2 MINI WHEELBARROW COMPRESSOR OIL LUBE PUMP - POMPE A HULE - BOMBA CON LUBRICACION DE ACI ETE 5 Gallon 18,8 Litre 18,7 Litro 4.4 SCFM @ 90PSI 0,12 m /Min @ 621 kPa 0,12 m /Min @ 6,21 bar 145 Max PSI 999 KpA 9,99 bar 3 3 T A N Q U E - T A N K - R E S E V I O R E N C H U F E - T A ...

  • RIDGID OL50145MW - page 11

    11 ASSEMBL Y INST ALLING THE DIPSTICK See Figure 4. The air compressor has a label installed between the oil fill hole and a travel cap. Before using the unit the first time, remove travel cap and label and insert supplied dipstick. Make sure to add oil befor e first use. See Checking the Oil before first time operation. CHECKING THE OIL See Figure ...

  • RIDGID OL50145MW - page 12

    12 ON OFF O I ON 0 2 4 6 40 80 120 160 bar 0 2 4 6 40 80 120 160 bar 1 TM 2 MINI WHEELBARROW COMPRESSOR OIL LUBE PUMP - POMPE A HULE - BOMBA CON LUBRICACION DE AC IETE OPERA TION DANGER: Do not disasse mble check valve, tank drain valves or safety relief valve with air in tank — bleed tanks. WARNING: Do not allow familiarity with products to make ...

  • RIDGID OL50145MW - page 13

    13 0 0 2 4 50 100 150 230 200 bar 100 0 0 16 5 50 150 200 230 bar psi TM 2 MINI WHEELBARROW COMPRESSOR OIL LUBE PUMP - POMPE A HULE - BOMBA CON LUBRICACION DE AC IETE  Attach 1/4 in. NPT male connector fitting to accessory or tool you intend to use.  Insert the other end of the male connector to the quick coupler on the open end of hose. WARN ...

  • RIDGID OL50145MW - page 14

    14 CHECKING THE SAFETY V AL VE See Figure 12. DANGER: Do not attempt to tamper with the safety valve. Anything loosened from this device could fly up and hit you. Failur e to heed this warning could result in death or serious personal injury . The safety valve will automatically release air if the air tank pressur e exceeds the preset maximum. The ...

  • RIDGID OL50145MW - page 15

    15 ON OFF O I ON MAINTENANCE WARNING: When servicing use only identical RIDGID ® replacement parts. Use of any other parts may create a hazar d or cause product damage. WARNING: Always wear safety goggles or safety glasses with side shields during power tool operation or when blowing dust. If operation is dusty , also wear a dust mask. WARNING: Al ...

  • RIDGID OL50145MW - page 16

    16 ON OFF O I ON MAINTENANCE Fig. 15 DRAIN PLUG OIL FILL HOLE COLLECT USED OIL IN A SUIT ABLE CONT AINER CHANGING THE OIL See Figure 15. Replace the oil after the first 100 hours of operation and every 100 hours following the first oil change.  Place a suitable container underneath the drain to collect used oil.  Remove the drain plug with a ...

  • RIDGID OL50145MW - page 17

    17 TROUBLESHOOTING PROBLEM CAUSE SOLUTION Compressor will not run Loss of power or overheating No electrical power Blown shop/house fuse Shop/house breaker open Thermal overload open Pressur e switch bad T ank is full of air C h e c k f o r p ro p e r u s e o f e x t e n s i o n cord Ch ec k to b e su re u ni t is pl ug ge d i n Check fuse/breaker ...

  • RIDGID OL50145MW - page 18

    18 Proof of purchase must be presented when requesting war - ranty service. This product is manufactured by One W orld T echnologies, Inc. The tra demark is lice nsed from RIDGID, Inc. Al l warra nty commu nication s shoul d be directe d to One W orld T echnolo- gie s, Inc., att n: RIDGI D Ha nd Held and Statio nary Pow er T ool T echnical Service ...

  • RIDGID OL50145MW - page 19

    19 NOTES ...

  • RIDGID OL50145MW - page 20

    20 Customer Service Information: For parts or service, contact your near est RIDGID ® authorized service center . Be sure to provide all relevant information when you call or visit. For the location of the authorized service center nearest you, please call 1-800-4-RIDGID or visit us online at www .ridgid.com. The model number of this product is fo ...

Produzent RIDGID Kategorie Air Compressor

Dokumente, die wir vom Produzenten des Geräts RIDGID OL50145MW erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen RIDGID
- Bedienungsanleitungen OL50145MW
- Produktkarten RIDGID
- Informationsbroschüren
- oder Energieetiketten RIDGID OL50145MW
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung RIDGID OL50145MW.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen RIDGID OL50145MW, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen RIDGID OL50145MW. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts RIDGID OL50145MW ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts RIDGID OL50145MW, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von RIDGID OL50145MW hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von RIDGID OL50145MW verständlich ist.

Eine gänzliche Bedienungsanleitung von RIDGID sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von RIDGID OL50145MW bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von RIDGID OL50145MW befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich RIDGID OL50145MW, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts RIDGID OL50145MW - die uns die ersten Schritte während der Nutzung von RIDGID OL50145MW erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit RIDGID OL50145MW hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von RIDGID OL50145MW im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich RIDGID OL50145MW?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit RIDGID OL50145MW nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit RIDGID OL50145MW hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)