  • Johnson Controls r-410a - page 1

    Johnson Controls Unitary Produ cts 835964-UIM-A-0112 R-410A OUTDOOR SPLIT -SYSTEM AIR CONDITIONING MODELS: 13 & 14.5 SEER - TCG(D,F)/GCGD/TCJ(D,F)/YCJ(D,F) SERIES 1.5 TO 5 TONS – 1 & 3 PHASE INSTALLATION MANUAL ® LIST OF SECTIONS GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ‘1 SAFETY ...

  • Johnson Controls r-410a - page 2

    835964-UIM-A-0112 2 Johnson Controls Unitary Products LIMIT A TIONS The unit should be installed in accordance with all National, S tate and Local Safety Codes and the limitations listed below: 1. Limitations for the indoor unit, coil, and appropriate accessories must also be observed. 2. The outdoor unit must not be installed with any duct work in ...

  • Johnson Controls r-410a - page 3

    835964-UIM-A-0112 Johnson Controls Unitary Produ cts 3 GROUND IN ST ALLA TION The unit should be installed on a soli d base that is 2” (5.1 cm) above grade and will not shift or settle, causing strain on the refrigerant lines and possible leaks. Maintain the clearances shown in Figure 1 and install the unit in a level position. The base pad shoul ...

  • Johnson Controls r-410a - page 4

    835964-UIM-A-0112 4 Johnson Controls Unitary Products PRECA U TI ON S DURING BRAZING OF LINES All outdoor unit and evaporator co il connections are copper-to-coppe r and should be brazed with a phosphor ous-copper alloy material such as Silfos-5 or equivalent. DO NOT use soft solder . The out door units have reusable service valves on bot h the liq ...

  • Johnson Controls r-410a - page 5

    835964-UIM-A-0112 Johnson Controls Unitary Produ cts 5 SECTION IV : ORIFICE INST ALLA TION Install Schrader V alve Core and Orifice as follows: 1. Slide indoor coil out of cabinet far enough to gain access to equal- izer fitting on the suction line. 2. After holding charge is complete ly discharged remove black plas- tic cap on equalizer fitting. 3 ...

  • Johnson Controls r-410a - page 6

    835964-UIM-A-0112 6 Johnson Controls Unitary Products SECTION VII: SY STEM CHAR GE The factory charge in the outdoor unit includes eno ugh charge for the unit, a 15 ft. (4.6 m) line set, and the smallest indoor coil match-up. Some indoor coil matches may r equire additional charge. See tabular data sheet provided in unit literature packet for charg ...

  • Johnson Controls r-410a - page 7

    835964-UIM-A-0112 Johnson Controls Unitary Produ cts 7 SECTION VIII: ELECTRICAL CONNECTIONS GENERAL INFORMA TION & GROUNDING Check the electrical supply to be sure that it meets the values specified on the unit nameplate and wiring lab el. Power wiring, control (low voltage) wiring, disconnect switch es and over current protection must be suppl ...

  • Johnson Controls r-410a - page 8

    835964-UIM-A-0112 8 Johnson Controls Unitary Products FIELD CONNECTIONS CONTR OL WIRING 1. Route low voltage wiring into bottom of control box as shown in Figure 6. Make low voltage wiri ng connections inside the low volt- age box per Figures 7 - 1 1. 2. The complete connection diag ram and schematic wiring label is located on the inside surface of ...

  • Johnson Controls r-410a - page 9

    835964-UIM-A-0112 Johnson Controls Unitary Produ cts 9 For additional connection diagrams for a ll UP G equipment refer to “Low V olt age System Wiring” document available online at www . upgnet.com in the Product Catalog Section. FIGURE 10: Thermostat Chart - Single S tage AC with PSC Air Handler AC 1A Single Stage Air Conditioner – PSC Air ...

  • Johnson Controls r-410a - page 10

    835964-UIM-A-0112 10 Johnson Controls Unitary Products FIGURE 1 1: Thermostat Chart - Single S t age AC with PSC Air Handler AC 1B Single Stage Air Conditioner – PSC Air Handler C 24 – Volt Comm on Y Compressor Contactor SINGLE STAGE AIR CONDIT IONER MA SHP AHP ID MODELS SINGLE STAGE AIR CONDITI ONER Other Part Nu mbers: SAP = Legacy 265902 = 0 ...

  • Johnson Controls r-410a - page 11

    835964-UIM-A-0112 Johnson Controls Unitary Produ cts 11 FIGURE 12: Thermostat Chart - Single S tage AC with PSC Furnace AC 5D Single Stage Air Conditioner – Single Stage PSC Furnace HM1 Humidistat Y Full Stage Compressor G Fan *PP11C70224 THERMOSTAT RH 24 – Volt Hot (Heat XFMR) RC 24 – Volt Hot (Cool XFMR) W Full Stage Heat Clipping Jump er W ...

  • Johnson Controls r-410a - page 12

    835964-UIM-A-0112 12 Johnson Controls Unitary Products FIGURE 13: Thermostat Chart - Single S tage AC with PSC Furnace AC 5E Single Stage Air Conditioner – Single Stage PSC Furnace C 24 – Volt Comm on Y Compressor Contactor SINGLE STAGE AIR CONDIT IONER SINGLE STAGE AIR CONDITI ONER Y Full Stage Compressor G Fan *BP11C50124 *BN11C01124 *DP11C40 ...

  • Johnson Controls r-410a - page 13

    835964-UIM-A-0112 Johnson Controls Unitary Produ cts 13 SECTION IX: INSTRUCTING THE O WNER Assist owner with processing warr anty cards and/or online registration. Review Owners Guide and provide a copy to the owner and guidance on proper operation and maintenance. Instr uct the owner or the opera- tor how to start, stop and adjust temperature sett ...

  • Johnson Controls r-410a - page 14

    835964-UIM-A-0112 14 Johnson Controls Unitary Products SECTION X: WIRING DIAGRAM FIGURE 14: Wiring Diagram - Single Phase *167242* ...

  • Johnson Controls r-410a - page 15

    835964-UIM-A-0112 Johnson Controls Unitary Produ cts 15 FIGURE 15: Wiring Diagram - Three Phase *412217* ...

  • Johnson Controls r-410a - page 16

    Subject to change without not ice. Published in U.S.A. 835964-UIM-A-0112 Copyright © 2012 by Johnson Controls, Inc. All ri ghts reserved. Supersedes: 414172-UIM-D-1211 Johnson Contro ls Unit ary Produc t s 5005 Y ork Driv e Norman, OK 73069 NOTES ...

Produzent Johnson Controls Kategorie Air Conditioner

Dokumente, die wir vom Produzenten des Geräts Johnson Controls r-410a erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Johnson Controls
- Bedienungsanleitungen r-410a
- Produktkarten Johnson Controls
- Informationsbroschüren
- oder Energieetiketten Johnson Controls r-410a
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Johnson Controls r-410a.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Johnson Controls r-410a, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Johnson Controls r-410a. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Johnson Controls r-410a ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Johnson Controls r-410a, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Johnson Controls r-410a hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Johnson Controls r-410a verständlich ist.

Eine gänzliche Bedienungsanleitung von Johnson Controls sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Johnson Controls r-410a bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Johnson Controls r-410a befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Johnson Controls r-410a, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Johnson Controls r-410a - die uns die ersten Schritte während der Nutzung von Johnson Controls r-410a erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Johnson Controls r-410a hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Johnson Controls r-410a im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Johnson Controls r-410a?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Johnson Controls r-410a nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Johnson Controls r-410a hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)