Bedienungsanleitung Lathem DWA-S

28 Seiten 0.46 mb
Download

Zur Seite of 28

Summary
  • Lathem DWA-S - page 1

    Sonachron ® ( DWA-S) User’s Manual ...

  • Lathem DWA-S - page 2

    Lathem T ime Corporation 200 Selig Dr ive, SW Atlanta, GA 30336 1-800-241-49 90 1-404-691-04 00 www.lathem .com Docum ent No. OMSC-07 08 Copyright © 2008 Lathem T ime Corporation. All rights res erved. ...

  • Lathem DWA-S - page 3

    T A BLE OF CON TENTS SPECIFICATI ONS ..... .......... .......... .......... ......... ......... 1 INTRODUCT ION ......... .......... .......... .......... .......... ...... 2 QUICK START STEPS ......... .......... .......... .......... ....... 3 DIP SWIT CH SETTINGS...... .......... .......... .......... ....... 8 PROGRAMMING A SECURITY CODE ...... ...

  • Lathem DWA-S - page 4

    Page 1 SPECIFIC A TION S Input Voltage 115 VAC (22 0 Optional) Input Frequ ency 50/60 Hz Input Power 20 W atts Max Standb y Power 1.2 Ah, 6 V bat tery Standb y Time 10 Days Timing Acc uracy Per line fr equenc y Num ber of Events 1440 (an y combination of week days) Signal Dura tion Programm able – 1 to 99 s ecs Daylight Sa vings Automatic (D isab ...

  • Lathem DWA-S - page 5

    Page 2 INTRODU CTION The DW A-S is a single c ircuit signa ling device which can b e used as a be ll ringer or o n/off controller. It is c apable of retaining up to 1440 sep arate e vents for each day of the week in mem ory plus a float ing lunch a nd break schedule which can be activated with a singl e ke y on the keypad or a r emote sw itch. Auto ...

  • Lathem DWA-S - page 6

    Page 3 QUICK ST ART S TEPS Step 1 – M ount Unit to Wall 1. Unscrew 2 l eft scr ews to rem ove left side panel. 2. Slide front pan el left. 3. Disconnect ca ble connec tor f rom right side of f ront panel. 4. Slide front pan el left and r em ove completel y. 5. Find a suitab le location on the wall that allows at least 10 inches of cle arance on t ...

  • Lathem DWA-S - page 7

    Page 4 9. Secure unit to wall using screws (n ot provide d). Step 2 – Sw ith Off Po wer to AC Circuit 1. S W IT CH OFF T HE CIRCUIT THAT W ILL FEED AC P OW ER TO T HE UNIT BEFORE PROCEDING . Step 3 – Con nect Wires f or 115V AC or 24V AC Bells IMPO RTANT! This unit is shipped f rom the fa ctory as a Bell Ringer. To change to an ON/O FF controll ...

  • Lathem DWA-S - page 8

    Page 5 IMPO RTANT: DO NOT PROCEED IF W IRE COLORS ARE DIFFERENT TH AN SHOWN OR IF YOU ARE UN SURE W HICH W IR ES ARE AC HOT , AC NEUTRAL AND GROUND. T HERE IS R ISK OF PER SONAL INJU RY AND DAMAGE T O THE UNIT THAT ’S NOT COVER ED BY W ARRANTY. INEXPEN SIVE TEST ERS ARE AVAILAB LE AT YOUR LO CAL HOM E ELECT RICAL SUP PLY STOR E FOR VERIF YING W I ...

  • Lathem DWA-S - page 9

    Page 6 Step 5 – Secu re Cover 1. Align front pan el in trac k and slide h alf wa y to right. 2. Secure ribb on cable on r ight edge of front panel . 3. Slide front pan el all the way closed m ak ing sure that the cable la ys down. 4. Attach red b attery wire o nto batter y post. 5. Secure left s ide panel with the scr ews. Step 8 – Re store Pow ...

  • Lathem DWA-S - page 10

    Page 7 Step 9 – T est Signaling 1. Your displa y should ap pear as s hown in the pictur e bel ow. If not, please c ontact your d ealer or Lathem Time directly. 2. Enter a secur ity code us ing the da y of week k eys (remem ber the days that you selected) . 3. Press Run to return to the norm al display sh owing cur rent time of day. 4. Press the M ...

  • Lathem DWA-S - page 11

    Page 8 DIP SWITCH SE TTINGS To acc ess the dip switches , rem ove the two scr ews holding t he left side panel in place and rem ove the panel. Dip S witches 1, 2, and 3 ar e monitored at all tim es and changes take eff ect immediatel y. Dip Switch 4 is read onl y at power up. T o change the s etting for th is switch, the unit m ust be powere d com ...

  • Lathem DWA-S - page 12

    Page 9 PROGR A MM IN G A SEC URITY CODE Upon power up you are allowed to en ter a secur ity code to restrict acc ess to program m ing functions. W hen the unit displays “ SECURITY CODE ”, press from one to four Da y of the W eek keys. This is your securit y code. The ER ASE EVENT ke y can be used t o clear th e code for re-entry. Pr ess the RU ...

  • Lathem DWA-S - page 13

    Page 10 UNLOCKI NG THE KEYP AD To unlock the ke ypad, press the Da y of the W eek keys you programm ed for the security code f ollowed b y RUN . The security k eys mus t be pressed in the exact ord er as the y were originall y entered. The d isplay shoul d read “ S ELECT FUNCT ION .” T o relock the ke ypad, simply press RUN . T he ke y pad m us ...

  • Lathem DWA-S - page 14

    Page 11 PROGR A MM IN G EVENTS (On/Off Con troller) NOT E: Dip Switch 4 m ust be set to OF F (see pa ge 8) W ith “ SELECT FUNCT ION ” displa yed, press the PRGM EVENTS k ey. The disp lay should rea d “ CONT ROL 12:00 AM .” Use the F AST FWD and SLOW FWD ke ys to advance the displayed tim e to the desir ed e vent time. O nce the eve nt time ...

  • Lathem DWA-S - page 15

    Page 12 PROGR A MM IN G EVENTS (Bell Ringer ) NOT E: Dip Switch 4 m ust be set to O N (see p age 8) W ith “ SELECT FUNCT ION ” displa yed, press the PRGM EVENTS k ey. The disp lay should rea d “ SIGN AL 12:00 AM ” “ ON DAYS: ” Us e the F AST FWD and SLOW FW D ke ys to advance the displa yed time to the desired e vent time. Onc e the eve ...

  • Lathem DWA-S - page 16

    Page 13 M A NU A L LUNC H A ND BRE AKS (Bell Ringer ) This f unction provides a m eans of programm ing set lun ch and break lengt hs which can be initiated at various t imes during the day. It is on ly available when the u nit is used as a Bell Ringer and operatin g on AC po wer. Press ing the ST ART LU NCH or ST A RT BREAK ke y at the k eypad (or ...

  • Lathem DWA-S - page 17

    Page 14 SIGN A L ON/OF F Pressing the SIGN AL ON/OFF key when the k eypad is unlocked changes the O n/Off status of the progr amm ed schedule. W hen the status is O N, bells or c ontrols will operate bas ed on the schedule. W hen the stat us is OFF, the s chedu le is ignor ed and only the m anual k ey will operate t he bells or contr ols. T he curr ...

  • Lathem DWA-S - page 18

    Page 15 MASTER CLOCK - 1 2 3 4 5 10 1 1 12 13 6 7 8 9 TxD RxD D + D G N D G N D S Y N C D + D - D + D - ~ ~ RS-232 RS-485 SYNC OUT SYNC IN 12V~ AC OUT 250ma MODEM HOST COMMUNICA TIONS L TR8-512 & LTR8-512M Only PULSE SYNC RS-485 DA T A SYNC + - RS-485 DSD RS-485 DSD + - RS-485 DSD + - RS-485 DSD + - RS-485 DSD + - + - RS485 The DW A-S comes equ ...

  • Lathem DWA-S - page 19

    Page 16 FIGURE 2: CONNECT ION FOR DW A-S TO LTR-0 FIGURE 3: CONNECT ION FOR DW A-S TO LTR-GPS ...

  • Lathem DWA-S - page 20

    Page 17 FIGURE 4: CONNECT ING RC-M S TO SYNC H DW A-S OR LTR- 0 NOTE: A 9vDC Power Adapter (not shown) is also required for the RC-MS. FIGURE 5: OMC – DW A-S INTERCO NNECT ION ...

  • Lathem DWA-S - page 21

    Page 18 Sonachron (DW A-S) can be s ynchronized to Lat hem ’s LTRx- 512 master, LT R-0 mas ter, LTR-GPS rece iver, RC-M S master or Omni:ChronI I time clock referenc e devices. D istance fr om the source can b e extende d using Lathem ’s SW IFT485+ repeat er. Omni:ChronI I Tim e Recorder can be equippe d with an optional RS485 trans mitter f or ...

  • Lathem DWA-S - page 22

    Page 19 ...

  • Lathem DWA-S - page 23

    Page 20 FIGURE 6: 115/220 V AC BELL WIRI NG FIGURE 7: LOW VOL T A GE AC BELL W IRING ...

  • Lathem DWA-S - page 24

    Page 21 FIGURE 8: LOW VOL T A GE DC B ELL W IRING FIGURE 9: 115/220 V AC CONT ROL WIRING ...

  • Lathem DWA-S - page 25

    Page 22 FIGURE 10: LOW VOL T A GE AC CONTROL WIRING FIGURE 11: LOW VOL T A GE DC CON TROL WIRING ...

  • Lathem DWA-S - page 26

    Page 23 FIGURE 12: DRY CONT ACT W IRING FOR P AGING SYSTEM OR TO NE GENER A TOR ...

  • Lathem DWA-S - page 27

    Page 24 Limited One-Year L imited Warranty La the m w a rr an ts t he ha rd wa re p ro du ct s de scr ib ed i n thi s gu id e ag ai ns t def ec t s i n ma ter ia l an d wo rk man sh ip f or a pe r io d o f on e y ea r fr o m d a te of or i gi nal pur ch a se fro m La th e m or fro m an a u tho riz e d Lat he m re se lle r . T he c on di tio n s o f ...

  • Lathem DWA-S - page 28

    OMSC-0708 ...

Produzent Lathem Kategorie Time Clock

Dokumente, die wir vom Produzenten des Geräts Lathem DWA-S erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Lathem
- Bedienungsanleitungen DWA-S
- Produktkarten Lathem
- Informationsbroschüren
- oder Energieetiketten Lathem DWA-S
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Lathem DWA-S.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Lathem DWA-S, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Lathem DWA-S. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Lathem DWA-S ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Lathem DWA-S, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Lathem DWA-S hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Lathem DWA-S verständlich ist.

Eine gänzliche Bedienungsanleitung von Lathem sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Lathem DWA-S bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Lathem DWA-S befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Lathem DWA-S, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Lathem DWA-S - die uns die ersten Schritte während der Nutzung von Lathem DWA-S erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Lathem DWA-S hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Lathem DWA-S im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Lathem DWA-S?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Lathem DWA-S nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Lathem DWA-S hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)