  • Anton/Bauer DIONIC 90 - page 1

    ® BATTERY SYSTEM DIONIC ® 90 lithium ion Digital Battery OWNER’S MANUAL ...

  • Anton/Bauer DIONIC 90 - page 2

    TABLE OF CONT ENTS IMPORTANT READ AND UNDERSTAND T HIS MANUAL BEFORE OPER ATION .................................................................... 1 INTRODUCTION .............................................................................. 2 FEATURES ...................................................................................... 3 CHARGIN ...

  • Anton/Bauer DIONIC 90 - page 3

    1 IMPORTANT READ AND UNDERSTAND THIS MANUAL BEFORE OPERATION The InterActive 2000 Dionic 90 battery lithium ion chemistry delivers a higher power to weight ratio than NiCd & NiMH. However, all lithium ion batteries have more sensitive char ging and discharging param eters and require longer charge times (2-5 hours). See charging section page 5 ...

  • Anton/Bauer DIONIC 90 - page 4

    2 INTRODUCTION The development of this new DIONIC 90 battery sy stem has been made possible through the incorporation of the pioneering InterActive technology of the Anton/Bauer Digital system with the very latest lithium ion cell formulations. Each DIONIC 90 battery features an on-board “fuel computer” to monitor ener gy put into a nd taken ou ...

  • Anton/Bauer DIONIC 90 - page 5

    3 FEATURES 1. Microprocessor Fu el Computer - Accurately monitors the energy in the battery with programs that take into account battery age, self discharge, charge/discharge rate, operating conditions and previously experienced charge/discharge cycles. The DIONIC 90 battery constantly “learns” its precise state of charge and rem aining capacit ...

  • Anton/Bauer DIONIC 90 - page 6

    4 CHARGING DIONIC 90 BATTERIES • DO NOT ATTEMPT TO CHARGE THIS BATTERY WITH ANY CHARGER OTHER THAN THE ANT ON/BAUER InterActive 2000 OR T SERIES CHARGERS SPECIFIED IN THIS MANUAL. • Allow the battery to reach a steady green (LifeS aver ® ) mode before using for the first time. Please read the in dividu al charger Owner’s Manual to be come ac ...

  • Anton/Bauer DIONIC 90 - page 7

    5 NOMINAL CHARGE TIMES FOR DIONIC 90 Charge Le v el LED Indicators 90% Flashing Green 100% Steady Green Dual 2722 (2 batteries simultaneously) 2hrs. 3hrs. InterActive 2000 Pow erCharger (Quad/Dual – 2702/2701/2700) (Quad/Dual – 2401/2400) 2 hrs. 3 hrs. T2 (2 batteries simultaneously) 2hrs. 3hrs. Tandem 70 2hrs. 3hrs. Twin (2 batteries simultane ...

  • Anton/Bauer DIONIC 90 - page 8

    6 The DIONIC 90 features an all NEW “RealTime” LCD display providing on-the-fly remaining run time estimates in 15 minute increm ents as well as simultaneously providing remaining capacity information using the traditional “Fuel Gauge” approach. No s pecial adapters or s et up is required. RealTime automatically calculates the load and disp ...

  • Anton/Bauer DIONIC 90 - page 9

    7 -The large numbers 1, 2 or 3 indicate remaining hours under current load (only one number will display at any one time) -The pie chart numbers ( 15, 30, 45, or 60) indicate remaining minutes under current load. - The InterActive Segment indicates a FULLY CHARGED battery verified by charger communication -Top BAR: Indicates 75%-96% - 2 nd BAR: Ind ...

  • Anton/Bauer DIONIC 90 - page 10

    8 If the SIDE BARS (only) flash AND other icons are lit and not flashing, this indicates the battery has requested to be fully charged and discharged in order to update its “learned capacity”. This “learning” should typically occur during normal equipment operation. However, if the battery has not been fully charged and discharged for some ...

  • Anton/Bauer DIONIC 90 - page 11

    9 RealTime Display Indications • When the DIONIC battery is being charged remaining runtime is not displaye d. • Rem aining run time is calculated using the present available battery capacity and a constantly updated accurate measurement of the present load on the battery. • If no load is detected, or if the battery is removed from the charge ...

  • Anton/Bauer DIONIC 90 - page 12

    10 • W hen the battery is completely discharged the LCD will flash the 15 minute icon and the ‘RES’ bar until the battery is returned to a charger. • If the protection electronics detect a low battery voltage condition (any one cell reaches roughly 2.5Vdc or approximately 10V battery voltage), the LCD sidebars will flash until the battery i ...

  • Anton/Bauer DIONIC 90 - page 13

    11 OPERATING GUIDELINES 1. Keep batteries cool or at room temp eratures whenever poss ible. Sustained elevated temperatures are the primary reason for premature failure of lithium ion batteries: a. Charging - Charge batteries at room temperature. In warm climates keep chargers in air conditioned rooms for best performance. b. On assignment - Do not ...

  • Anton/Bauer DIONIC 90 - page 14

    12 4. Low voltage batteries can also be caused by allowing batteries to remain off the charger for extended periods causing the LCD display to be blank, indicating that the electronic circuitry has removed all load from the battery cells – including the display. In the case that the battery is in a low voltage condition the battery should be retu ...

  • Anton/Bauer DIONIC 90 - page 15

    13 SERVICE In the event a DIONIC 90 battery fails to deliver acceptable performance, it must be returned to the Anton/Bauer. No ot her facility is qualified and equipped to service the InterActive 2000 DIONIC 90 ba tteries and calibrate the electronic components and sensors. Any attempt by the user or any other unauthorized persons to service this ...

  • Anton/Bauer DIONIC 90 - page 16

    14 PRECAUTIONS 1. Do not expose this battery to high temperatures (above 50°C/120°F). This includes storage in direct sunlight , in cars in hot weather, or in close proximi ty to heating devices. This may cause electrolyte leak age, impaired p erformance and shorten ing of battery s ervice life. 2. When not u sing the b attery for prolonged perio ...

  • Anton/Bauer DIONIC 90 - page 17

    15 DIONIC 90 BATTERY SPECIFICATIONS OUTPUT VOLTA GE 14.4v Nominal 12.4 ~ 16.8v Operating CA PA CITY (CELL CA PA CITY) 90 WH Nominal (6.3 AH Rated) FUSE Internal 8amp RECOMMENDED OPERA TION 15 - 50 watts 1 (MAXIMUM DISCHARGE RATE) (90 watts) 2 TYPICA L RUN-TIME @ 20w - 4 ½ hrs. @ 25w - 3 ½ hrs. @ 40w - 2 ¼ hrs. WEIGHT 1.7 lbs SIZE 5 1/4 x 3 1/2 x ...

  • Anton/Bauer DIONIC 90 - page 18

    16 LIMITED WARRANTY This w arranty for the ba ttery product specif ied in this doc ume nt (“ Product”) is g iven by A nton/Bauer , Inc. (“Anton/Baue r”), 14 Progres s Driv e, Shelton, Conne cticut 06484. I f y ou (the purchas er of the Product f rom A nton/Bauer , or the person for whom the Product wa s purchas ed, if it wa s a gi ft) ha ve ...

  • Anton/Bauer DIONIC 90 - page 19

    17 Dangerous Goods Regulations 49C FR Parts 100-185, Air Transport Association (IATA) and the International Civil Aviation Organization (ICAO) regulations a pply to all lithium ion battery transport. Air Transportation Declaration Anton/Bauer, Inc. declares that the Dionic 90 lith ium ion b attery pack contains equivalent lithium c onte nt (ELC) in ...

  • Anton/Bauer DIONIC 90 - page 20

    7595-0243 Rev M The power behind the best cameras capturing the best im ages in the world. sm The following are trademarks of Anton/Bauer, Inc.: ACS, ADM, All Chem, Anton/Bauer, Anton/Bauer logo and parallelogram design, Automatique, Egripz, Elightz, Elipz, Essentialz, DataTap, Dionic, Gold Mount, Hy TRON, Im pac, InterActive and design, Life Saver ...

Produzent Anton/Bauer Kategorie Camcorder Accessories

Dokumente, die wir vom Produzenten des Geräts Anton/Bauer DIONIC 90 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Anton/Bauer
- Bedienungsanleitungen DIONIC 90
- Produktkarten Anton/Bauer
- Informationsbroschüren
- oder Energieetiketten Anton/Bauer DIONIC 90
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Anton/Bauer DIONIC 90.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Anton/Bauer DIONIC 90, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Anton/Bauer DIONIC 90. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Anton/Bauer DIONIC 90 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Anton/Bauer DIONIC 90, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Anton/Bauer DIONIC 90 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Anton/Bauer DIONIC 90 verständlich ist.

Eine gänzliche Bedienungsanleitung von Anton/Bauer sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Anton/Bauer DIONIC 90 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Anton/Bauer DIONIC 90 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Anton/Bauer DIONIC 90, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Anton/Bauer DIONIC 90 - die uns die ersten Schritte während der Nutzung von Anton/Bauer DIONIC 90 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Anton/Bauer DIONIC 90 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Anton/Bauer DIONIC 90 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Anton/Bauer DIONIC 90?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Anton/Bauer DIONIC 90 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Anton/Bauer DIONIC 90 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)