    450, 700, 1250 V A 230V PowerSure TM Personal XT U SER M ANUAL English / Deutsch / Français / Italiano / Español PS PXT-inglese.qxd 6-06-2001 9:51 Pagina 1 ...

  • Emerson PowerSure Personal XT - page 2

    2 IMPORT ANT SAFETY INSTRUCTIONS SA VE THESE INSTRUCTIONS This manual contains important safety instructions that should be followed during the installation and maintenance of the UPS and its batteries. Please read this manual thoroughly before attempting to install or operate this UPS. This equipment can be installed and operated by individuals wi ...

  • Emerson PowerSure Personal XT - page 3

    3 These units bear TUV GS mark, CE mark and comply with the following standards (limits value class B): EN 60950 (1998.8), EN 50091-1 (1994.4), EMI/RFI: EN550222 class B EMS: IEC 1000-4-2 (ESD) Level 3 IEC 1000-4-3 (RS) Level 3 IEC 1000-4-4 (EFT) Level 3 IEC 1000-4-5 (Lightning surge) Level 3 CAUTION: Although your UPS has been designed and manufac ...

  • Emerson PowerSure Personal XT - page 4

    4 INTRODUCTION & SYSTEM DESCRIPTION MAJOR COMPONENTS Congratulations on your choice of the Liebert PowerSure Personal XT Uninterruptible Power System (UPS). It provides conditioned power to microcomputers and other sensitive electronic equipment. ! PowerSure OUTPUT “Lead-acid battery inside the enclosure” “Blei-Akkumulator innerhalb des G ...

  • Emerson PowerSure Personal XT - page 5

    5 GENERAL INST ALLA TION ! PowerSure ! PowerSure ! PowerSure ! PowerSure OUTPUT “Lead-acid battery inside the enclosure” “Blei-Akkumulator innerhalb des Gehause” INPUT FUSE:250V~,5A,T RS232 MODEL:YUNTO Q700 IMPUT:230V~,50/60Hz, 4.0A, 1Ø OUTPUT:230V~,50/60Hz, 700VA/420W , 3.1A MADE IN CHINA Remove from Box Remove Plug from Units and replace ...

  • Emerson PowerSure Personal XT - page 6

    6 NORMAL MODE OPERA TION BA TTER Y MODE OPERA TION 1. Inspect the packaging carton and its contents for damage. Please inform the trasport agency immediately should you find signs of damage. Please keep the packaging in a safe for future use. 2. Plug the UPS into a wall outlet (see figure 1). Let the UPS charge the battery for at least 2 hours. Y o ...

  • Emerson PowerSure Personal XT - page 7

    7 Switch and LEDs Symbol Function On/off T urn the UPS system an and off. 1. Steady: Input power is acceptable; the UPS is in normal mode (online) Status-LED 2. Blinking: Input power is out of (green) tolerance; the UPS is battery mode. 3. Off: No input power or the battery is exhausted or the UPS is switched off. 1. Blinking: The UPS is overloaded ...

  • Emerson PowerSure Personal XT - page 8

    8 If the UPS fails to operate properly , turn off the unit and repeat the steps in the installation section of this manual. If the problem persists, refer to the chart below: PROBLEM POSSIBLE CAUSE REMEDY No indication, no Check building wall outlet and mains cable by beep even UPS is No input voltage connecting another device with cable to this wa ...

  • Emerson PowerSure Personal XT - page 9

    9 Y ou can use MultiLink™ Software to allow your UPS to communicate to your computer via your DB-9 communications port. A MultiLink Software CD is included in the box, or you can download it from our web site at www .liebert.com. The PowerSure™ Personal XT UPS contains a standard DB-9 receptacle located on the rear of the UPS unit. Several sign ...

  • Emerson PowerSure Personal XT - page 10

    10 230V SPECIFICA TIONS ELECTRICAL SPECIFICA TION Model Number PSPXT450-230 PSPXT700-230 PSPXT1250-230 INPUT V oltage 230 V AC (197 - 262 V AC) Frequency 50 Hz ± 4Hz; 60 Hz ± 4Hz Amperage (maximum) 2.6 A 4.0 A 7.0 A Phase 12 φ 2W , Ground OUTPUT Power rating 450 V A - 270 W 700 V A - 420 W 1250 V A - 750 W V oltage 230 V AC ± 10% Frequency 50 H ...

  • Emerson PowerSure Personal XT - page 11

    11 LIMITED W ARRANTY Liebert Corporation extends the following LIMITED W ARRANTY to the purchaser and to its customer (collectively referred to as the "Purchaser"): the enclosed Uninterruptible Power System (UPS) and components are free from defects in materials and workmanship under normal use, service, and maintenance FOR A PERIOD OF TW ...

  • Emerson PowerSure Personal XT - page 12

    12 T echnical Support U.S.A. 1-800-222-5877 Outside the U.S.A. 614-841-6755 U.K. +44 (0) 1793 553355 France +33 (0) 1 43 60 01 77 Germany +49 89 99 19 220 Italy +39 02 98250 1 Netherlands +31 (0) 475 503333 E-mail upstech@liebert.com Web site http://www .liebert.com Worldwide F AX tech support +614-841-5471 The Company Behind The Products With more ...

Produzent Emerson Kategorie Uninterruptible power supply (

Dokumente, die wir vom Produzenten des Geräts Emerson PowerSure Personal XT erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Emerson
- Bedienungsanleitungen PowerSure Personal XT
- Produktkarten Emerson
- Informationsbroschüren
- oder Energieetiketten Emerson PowerSure Personal XT
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Emerson PowerSure Personal XT.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Emerson PowerSure Personal XT, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Emerson PowerSure Personal XT. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Emerson PowerSure Personal XT ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Emerson PowerSure Personal XT, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Emerson PowerSure Personal XT hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Emerson PowerSure Personal XT verständlich ist.

Eine gänzliche Bedienungsanleitung von Emerson sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Emerson PowerSure Personal XT bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Emerson PowerSure Personal XT befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Emerson PowerSure Personal XT, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Emerson PowerSure Personal XT - die uns die ersten Schritte während der Nutzung von Emerson PowerSure Personal XT erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Emerson PowerSure Personal XT hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Emerson PowerSure Personal XT im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Emerson PowerSure Personal XT?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Emerson PowerSure Personal XT nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Emerson PowerSure Personal XT hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)