Bedienungsanleitung Bradford-White Corp Convection Heater

28 Seiten 0.29 mb
Download

Zur Seite of 28

Summary
  • Bradford-White Corp Convection Heater - page 1

    238 - 43644 - 00C REV 12/03 A Spanish language version of these instructions is available by contacting the company listed on the rating plate. La version espanola de estas instrucciones se puede obtener al escribirle a la fabrica cuyo nombre aparece en la placa de especificaciones. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appli ance ...

  • Bradford-White Corp Convection Heater - page 2

    2 CONGRATULATIONS! You have just purchased one of the finest water heaters on the market today! This installation, operation and instruction manual will explain in detail the installation and maintenance of your new Gas Water Heater. We at Bradford White strongly recommend that you contact a plumbing professional for the installation of this water ...

  • Bradford-White Corp Convection Heater - page 3

    3 TABLE OF CONTENTS page GENERAL INFORMATION ............................................................ 4 INSTALLATION Locating The Water Heater .................................................... 6 Minimum Clearances ............................................................... 9 Venting ....................................................... ...

  • Bradford-White Corp Convection Heater - page 4

    4 GENERAL INFORMATION This ga s - fired water heater is design certified by CSA International under the applicable American National Standard, Z21.10.1 or CSA 4.1 - (as indicated on the rating plate), available from CSA International, 8501 East Pleasant Valley Road, Cleveland, OH U.S.A. 44131 - 5575. This water heater must be installed in accordanc ...

  • Bradford-White Corp Convection Heater - page 5

    5 General Information continued - This water heater has been manufactured for operation at altitudes from sea level to 2000 feet (610m) (unless otherwise specified on the water heater rating plate). For use of this appliance at an elevation greater than 2000 feet (610m), contact the dealer or manufacturer listed on the rating plate for information ...

  • Bradford-White Corp Convection Heater - page 6

    6 INSTALLATION LOCATING THE WATER H EATER This water heater MUST NOT be installed in any location where gasoline or flammable vapors are likely to be present, unless the installation is such to e liminate the probable ignition of gasoline or flammable vapors. Water heaters in residential garages must be installed and located, or protected, to avoid ...

  • Bradford-White Corp Convection Heater - page 7

    7 Installation (Locating The Water Heater) continued - Water heater corrosion and component failure can be caused by the heating and breakdown of airborne chemical vapors. Examples of some typical com pounds that are potentially corrosive are: spray can propellants, cleaning solvents, refrigerator and air conditioning refrigerants, swimming pool ch ...

  • Bradford-White Corp Convection Heater - page 8

    8 Installation (Locating The Water Heater) continued - Proper venting practices must be considered when selecting a location for this water heater. For exact venting specifications, please consult the Venting section of these Installation and Operating Instructions. The appliance sho uld be located in an area where leakage of the tank or connection ...

  • Bradford-White Corp Convection Heater - page 9

    9 Installation (continued) - MINIMUM CLEARANCES WARNING Failure to adhere to these installation and operating instructions may create a hazard to life and property and will n ullify the warranty. This installation shall allow access to the front of the water heater and adequate clearance shall be provided for servicing and operating this water heat ...

  • Bradford-White Corp Convection Heater - page 10

    10 Installation (continued) - VE NTING Place the draft diverter over the flue opening at the top of the water heater by inserting the tips of the draft diverter legs into the four (4) holes provided in the water heater top. On some models, line up the holes in the draft diverter legs wi th the holes provided on top of the water heater. Secure the d ...

  • Bradford-White Corp Convection Heater - page 11

    11 Combustion Air Supply Provide adequate air for combustion and ventilation. An insufficient supply of air will cause recirculation of combustion products resulting in air contamination that may be hazardous to life. Such a condition often will result in a yellow, luminous burner flame, causing carboning or sooting of the combustion chamber, burne ...

  • Bradford-White Corp Convection Heater - page 12

    12 Installation (continued) - All Air From Inside the Building: The confined space shall be provided with two permanent openings communicating directly with an additional room(s) of sufficient volume so that the combined volume of all spaces meets the criteria for an unconfined space. The total input of all gas utilization equipment installed in th ...

  • Bradford-White Corp Convection Heater - page 13

    13 WATER CONNECTIONS Note: BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE MAIN WATER SUPPLY VALVE. After shutting off the main water supply, open a faucet to relieve the water line pressure to prevent any water from leaking out of the pipes while ma king the water connections to the water heater. After the pressure has been relieved, close the ...

  • Bradford-White Corp Convection Heater - page 14

    14 WARNING For protection against excessive temperatures and pressure, install temperature and pressure protective equipment required by local codes, but not less than a combination temperat ure and pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or m ...

  • Bradford-White Corp Convection Heater - page 15

    15 Installation (Water Connections) continued - This water heater can deliver scalding temperature water at any faucet in the system. Be careful whenever using hot water to avoid scalding injury. Certain appliances such as dishwashers and automa tic clothes washers may require increased temperature water. By setting the thermostat on this water hea ...

  • Bradford-White Corp Convection Heater - page 16

    16 GAS CONNECTIONS The gas supply lines must meet all requirements of the National Fuel Gas Code ANSI Z223.1 - (Latest Edition) and/or in Canada CAN/CGA B149 Installati on Codes - (Latest Editions). The minimum permissible gas supply pressure for the purpose of input adjustment is 1.0” water column (.25kPa) above the operating manifold pressure. ...

  • Bradford-White Corp Convection Heater - page 17

    17 GENERAL OPERATION TO FILL THE WATER HEATER 1. Close the water heater drain valve by turning the knob clockwise . 2. Open the cold water supply shut - off valve. 3. Open several hot water faucets to allow air to escape from the system. 4. When a steady stream of water flows from the faucets, the water heater is filled. Close the faucets and check ...

  • Bradford-White Corp Convection Heater - page 18

    18 General Operation (continued) - INTERNET VERSION FOR REFERENCE ONLY ...

  • Bradford-White Corp Convection Heater - page 19

    19 THERMOSTAT ADJUSTMENT The thermostat dial is set to its lowest temperature setting when shipped from the factory. Remember that lower temperature settings are more energy efficient . Adjust the temperature by turning the thermostat dial. It is suggested that the starting point setting not be greater than the “ “ mark on the therm ostat dial ...

  • Bradford-White Corp Convection Heater - page 20

    20 General Operation (continued) - BURNER FLAME CHECKS Cast Iron B urner: At the time of installation and at periodic intervals (not more than 6 months), a visual check of the main burner and pilot flames should be made to determine if they are burning properly. For ideal operation, the gas and air must be properly prop ortioned. The proper air - g ...

  • Bradford-White Corp Convection Heater - page 21

    21 MAINTENANCE The following maintenance should be performed by a qualified service technician at the minimum periodic intervals suggested below. In some installations, the maintenance interval may be more frequent depending on the amount of use and the operating conditions of the water heater. Regular inspection and maintenance of the water heater ...

  • Bradford-White Corp Convection Heater - page 22

    22 Maintenance (continued) - 6. At least once a year, check the combination te mperature and pressure relief valve to insure that the valve has not become encrusted with lime. Lift the lever at the lever at the top of the valve several times until the valve seats properly without leaking and operates freely. 7. Monthly drain off a gallon of water t ...

  • Bradford-White Corp Convection Heater - page 23

    23 Maintenance (continued) - Contact your supplier or plumbing professional for replacement parts or contact the company at the address given on the rating plate of the water heater. Provide the part name, model and serial numbers of the water heater when or dering parts. READ THE WARRANTY FOR A FULL EXPLANATION OF THE LENGTH OF TIME THAT PARTS AND ...

  • Bradford-White Corp Convection Heater - page 24

    24 Figure 5 INTERNET VERSION FOR REFERENCE ONLY ...

  • Bradford-White Corp Convection Heater - page 25

    25 PARTS LIST DRAWING INTERNET VERSION FOR REFERENCE ONLY ...

  • Bradford-White Corp Convection Heater - page 26

    26 PART NAME AND DESCRIPTION 1. Draft Diverter 14. Drain Valve 2. Jacket Head Pan 15. Piezo Igniter 3. Jacket 16. Gas Valve 4. Outer Door 17. Steel Burner 5. Magnesium Anode – Hot Water Outlet 18. Orifice 6. Flue Baffle Assembly 19. Gas Feedline to Burn er 7. Dip Tube – Cold Water Inlet 20. Gas Feedline to Pilot 8. Temperature and Pressure Reli ...

  • Bradford-White Corp Convection Heater - page 27

    27 THE FOLLOWING INSTRUCTIONS ARE FOR INSTALLATION OF: GAS WATER HEATERS SUITABLE FOR WATER (POTABLE) HEATING AND SPACE HEATING 1. All piping components connected to this water heater for space heating applications must be suitable for use with potable water. In Massachusetts, space heating piping length must not exceed 50 feet. 2. Toxic chemicals, ...

  • Bradford-White Corp Convection Heater - page 28

    28 NOTES INTERNET VERSION FOR REFERENCE ONLY ...

Produzent Bradford-White Corp Kategorie Electric Heater

Dokumente, die wir vom Produzenten des Geräts Bradford-White Corp Convection Heater erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Bradford-White Corp
- Bedienungsanleitungen Convection Heater
- Produktkarten Bradford-White Corp
- Informationsbroschüren
- oder Energieetiketten Bradford-White Corp Convection Heater
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Bradford-White Corp Convection Heater.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Bradford-White Corp Convection Heater, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Bradford-White Corp Convection Heater. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Bradford-White Corp Convection Heater ansehen.

Die komplette Bedienungsanleitung des Geräts Bradford-White Corp Convection Heater, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Bradford-White Corp Convection Heater hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Bradford-White Corp Convection Heater verständlich ist.

Eine gänzliche Bedienungsanleitung von Bradford-White Corp sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Bradford-White Corp Convection Heater bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Bradford-White Corp Convection Heater befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Bradford-White Corp Convection Heater, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Bradford-White Corp Convection Heater - die uns die ersten Schritte während der Nutzung von Bradford-White Corp Convection Heater erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Bradford-White Corp Convection Heater hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Bradford-White Corp Convection Heater im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Bradford-White Corp Convection Heater?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Bradford-White Corp Convection Heater nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Bradford-White Corp Convection Heater hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)