Bedienungsanleitung Bradford-White Corp MI503*F(BN

28 Seiten 1.4 mb
Download

Zur Seite of 28

Summary
  • Bradford-White Corp MI503*F(BN - page 1

    SERVICE MANU AL Flammable V apor Ignition Resistant W ater Heater Troubleshooting Guide and Instruction f or Service (T o be perf ormed ONL Y b y qualified service providers) F or the Bradford White Defender Safety System ™ Models: MI30T*F(BN,CX)2 MI30S*F(BN,CX)2 MI303T*F(BN,CX)2 MI40T*F(BN,CX)2 MI403S*F(BN,CX)2 MI404T*F(BN,CX)2 MI503*F(BN,CX)2 M ...

  • Bradford-White Corp MI503*F(BN - page 2

    2 Flammable V apor Ignition Resistant W ater Heater T able of Cont ents P ag e Service Pr ocedur e Introduction 3 - - - T rouble shooting Char t 4 - - - Inner Door Gask et Remo val, Inspection, Replacement and Installation 5 RG-I Thermocouple T esting and Replacement 8 RG-II Pilot Assembly Inspection Cleaning and Replacement 1 0 RG-III Piezo Ignite ...

  • Bradford-White Corp MI503*F(BN - page 3

    3 Introduction The Br adf or d Whit e DEFENDER Safety Sy s t em ™ The Bradf ord Whit e DEFENDER Saf ety Sys t em TM was designed t o resis t t he ignition of flammable vapors that can occur outside of the water heater . Use and installation are nearly identical to previous versions of atmospherically f ired and vent ed wat er heaters. A number of ...

  • Bradford-White Corp MI503*F(BN - page 4

    4 S YMPT OM PR OB ABLE C A USE C ORRECTIVE A CTION Pilot Will Not Light 1 . No incoming gas or too low gas pressure. 2. Gas control knob set to wrong position. 3. Pilot light button not being fully depressed when attempting to light pilot. 4. Pilot orif ice or pilot tube is obstructed or kinked. 5. Pilot electrode not sparking to pilot. 6. Piezo ig ...

  • Bradford-White Corp MI503*F(BN - page 5

    SERVICE PROCEDURE RG-I Inner Door/Gask et Remo v al, Inspection R eplacement and R einstallation Inner Door Remo v al Pr ocedur e St ep 1 . R otate knob of the combination thermostat/g as valve to the “OFF” position. St ep 2. R emov e outer jack et burner access door St ep 3. Inner Door Remov al. a) Disconnect resettable thermal switc h wire le ...

  • Bradford-White Corp MI503*F(BN - page 6

    6 SERVICE PROCEDURE RG-I Inner Door/Gask et Remo v al, Inspection R eplacement and R einstallation Ins t allation of Inner Door wit h Gask et St ep 7 . Clean an y residual gask et residue or other debris from combustion chamber sur face before installing the inner door/gask et assembly . St ep 8. Place the lef t side inner door into position fir st ...

  • Bradford-White Corp MI503*F(BN - page 7

    7 SERVICE PROCEDURE RG-I Inner Door/Gask et Remo v al, Inspection R eplacement and R einstallation St ep 1 0. Firmly place right side inner door flange agains t the lef t side inner door f lange and secure with two 1/4” drive screws from step 3c. DO NOT O VER TIGHTEN SCREWS. St ep 1 1 . Align right side inner door to combustion chamber and verify ...

  • Bradford-White Corp MI503*F(BN - page 8

    8 SERVICE PROCEDURE RG-II Thermocouple T esting and Replacement Closed Cir cuit Ther mocouple T es ting St ep 1 . Disconnect thermocouple from combination thermostat/g as valve. St ep 2. Connect a thermocouple adapter (BWC P/N 239-44642-00, R ober tshaw P/N 75036) at the thermocouple location in the combination thermostat/g as valve. St ep 3. R eco ...

  • Bradford-White Corp MI503*F(BN - page 9

    9 SERVICE PROCEDURE RG-II Thermocouple T esting and Replacement Ther mocouple R eplacement St ep 1 . T ur n of f gas supply to water heater . Rotat e knob of combination thermostat/g as valve to “OFF” position. St ep 2. Remo ve outer jack et door . St ep 3. R emov e right side of inner door per SERVICE PROCEDURE RG-I, st eps 3a through 3c. St e ...

  • Bradford-White Corp MI503*F(BN - page 10

    10 SERVICE PROCEDURE RG-III Pilot Assembly Inspection, Cleaning and R eplacement Pilot/Electr ode Assembly Inspection, Cleaning and Replacement St ep 1 . T ur n of f gas supply to water heater . Rotat e knob of combination thermostat/g as valve to “OFF” position. St ep 2. Remo ve outer jack et door . St ep 3. R emov e right side of inner door p ...

  • Bradford-White Corp MI503*F(BN - page 11

    11 SERVICE PROCEDURE RG-IV Piezo Igniter , Electrode T esting and Replacement Piezo Ignit er , Electrode T esting and R eplacement With the pilot not in operation (no pilot f lame) y ou can check the Piezo and electrode circuit by viewing pilot thru the sight glass located on the inner door and observing the spark action. St ep 1 . Remo ve outer ja ...

  • Bradford-White Corp MI503*F(BN - page 12

    Combination Ther mos t at/Gas V al v e T esting and R eplacement The combination thermostat/gas valve is a non repairable device. If trouble shooting has determined a problem with the combination thermostat/g as valve, it must be replaced. If the bur ner and/or pilot do not function, service chec ks for gas pressure, thermocouple output, magnet ass ...

  • Bradford-White Corp MI503*F(BN - page 13

    THERMOC OUPLE TES TIN G See SERVICE PROCEDURE II MA GNET ASSEMBL Y TES TIN G St ep 1 . Disconnect thermocouple from combination thermostat/g as valve. St ep 2. Connect a thermocouple adapter (BWC P/N 239-44642-00, Robertshaw P/N 75036) at the thermocouple location in the combination thermostat/g as valve. St ep 3. R econnect thermocouple to adapter ...

  • Bradford-White Corp MI503*F(BN - page 14

    C OMBIN A TION THERMOS T A T/GAS V AL VE REPL A CEMENT St ep 1 . R otate knob of the combination thermostat/g as valve to the “OFF” position. St ep 2. T ur n of f gas supply to water heater . St ep 3. Disconnect gas supply line from combination thermostat/g as valve. St ep 4. T ur n of f water supply and drain water heater completely . St ep 5. ...

  • Bradford-White Corp MI503*F(BN - page 15

    15 St ep 7 . R emov al of combination thermostat/g as valve. a) Disconnect main bur ner feedline (3/4” wrench), pilot tube (7/1 6" wrench) and thermocouple (3/8" wrench) from combination thermostat/g as valve & remov e from the combustion chamber . b) R emov e Piezo brack et with Piezo igniter (refer to SERVICE PROCEDURE RG-IV) from ...

  • Bradford-White Corp MI503*F(BN - page 16

    St ep 9. R einstallation of inner door assembly . (cont.) b) Clean any gask et residue or other debris from combustion chamber surface before installing the inner door/gask et assembly . c) P osition thermocouple, pilot tube and Piezo wire against lef t side inner door flange gask et. DO N O T R OUTE THR OUGH R ADIUSED CHANNEL WITH FEEDLINE. Be sur ...

  • Bradford-White Corp MI503*F(BN - page 17

    MAIN BURNER: Inspection, A djus tment, Cleaning and Replacement At periodic intervals (not more then 6 months) a visual inspection should be made of the main bur ner f or proper opera- tion and to insure no debris accumulating. Main burner should light smoothly from pilot and burn with a blue f lame with a minimum of yellow tips. St eel burner mode ...

  • Bradford-White Corp MI503*F(BN - page 18

    MAIN BURNER: Inspection, A djus tment, Cleaning and Replacement (cont.) St ep 3. Full y inspect inner gask et per SERVICE PROCEDURE RG-I, st ep 4. Replace gask et if required follo wing SERVICE PROCEDURE I, st eps 5 & 6. St ep 4. Be cer tain that thermocouple, pilot tube and Piezo wire are routed b y inner door f lange as shown and Reinstall in ...

  • Bradford-White Corp MI503*F(BN - page 19

    BURNER CLEANIN G (cont.) St ep 5. Disconnect (unscrew) main burner (stamped steel “B” bur ner) from main burner orif ice or on cast iron bur ners (“C” burner), loosen air shutter & disconnect (unscrew) feedline from burner . St ep 6. Remo ve main burner orif ice from feed line (1/2” wrench on steel burner , 3/8" wrench on cast ir ...

  • Bradford-White Corp MI503*F(BN - page 20

    RESETT ABLE THERMAL SWIT C H C ONTINUIT Y TES TIN G St ep 1 . Remo ve outer jack et door . St ep 2. Disconnect wire leads from resettable thermal switc h. St ep 3. Using a multimeter capable of measuring continuity (Ohms), place one probe of meter on one of the brass connection tabs of the resettable thermal switch, and the remaining probe on the o ...

  • Bradford-White Corp MI503*F(BN - page 21

    RESETT ABLE THERMAL SWIT C H REPL A CEMENT St ep 1 . R otate knob of combination thermostat gas valve to the of f position. St ep 2. Remo ve outer jack et door . St ep 3. Disconnect wire leads from resettable thermal switc h. St ep 4. R emov e resettable thermal switc h from inner door (Phillips screw driver). St ep 5. Place new resettable thermal ...

  • Bradford-White Corp MI503*F(BN - page 22

    Scr eenLok Flame Ar r es t or Cleaning St ep 1 . R otate knob of combination thermostat gas valve to the of f position. St ep 2. Remo ve outer jack et door . St ep 3. Remo ve inner door per SERVICE PROCEDURE RG-I, st ep 3a through 3e. St ep 4. Disconnect main bur ner feed line (3/4 wrench), pilot tube (7/1 6 wrench) and thermocouple (3/8) wrench fr ...

  • Bradford-White Corp MI503*F(BN - page 23

    23 Dip T ube Inspection and R eplacement St ep 1 . R otate knob of combination thermostat/gas valve to “OFF” position. St ep 2. T ur n of f c old water supply to heater . Connect hose to drain spigot of wat er heater and rout e to an open drain. Open a nearby hot water faucet to vent heater f or draining. Open drain spigot of water heater and a ...

  • Bradford-White Corp MI503*F(BN - page 24

    24 Anode Inspection and R eplacement St ep 1 . T ur n of f water supply to water heater . Rotat e knob of combination thermostat/g as valve to “OFF” position. St ep 2. T ur n of f c old water supply to heater . Connect hose to drain spigot of wat er heater and rout e to an open drain. Open a nearby hot water faucet to vent heater f or draining. ...

  • Bradford-White Corp MI503*F(BN - page 25

    25 1 Draf t Hood 2 Hot Water Outlet/Anode 3 Cold Water Inlet T ube 4 Flue Baf f le 5 T&P Relief Valv e 6 Thermostat 7 Piezo Igniter 8 Brass Drain Valv e 9 Screw -#8- 1 8 x 3/4 Hex Washer Head 1 0 Screw -#1 0- 1 2 x 3/4 Hex Washer Head 1 1 Lef t Side Inner Door with Gasket 1 2 Complete Right Side Inner Door 1 2A Right Side Inner Door with Gasket ...

  • Bradford-White Corp MI503*F(BN - page 26

    26 Notes ...

  • Bradford-White Corp MI503*F(BN - page 27

    27 Notes ...

  • Bradford-White Corp MI503*F(BN - page 28

    Sales/ 800-523-2931 Fax/ 215-641-1670 Technical Support/ 800-334-3393 Fax/ 269-795-1089 W arranty/ 800-531-2111 Fax/ 269-795-1089 International: T elephone/ 215-641-9400 T elefax/ 215-641-9750 Ambler , P A 888-538-7833 Fax on Demand: bradfor dwhite.com www. For U.S. and Canada field service, contact your professional installer or local Bradford Whi ...

Produzent Bradford-White Corp Kategorie Water Heater

Dokumente, die wir vom Produzenten des Geräts Bradford-White Corp MI503*F(BN erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Bradford-White Corp
- Bedienungsanleitungen MI503*F(BN
- Produktkarten Bradford-White Corp
- Informationsbroschüren
- oder Energieetiketten Bradford-White Corp MI503*F(BN
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Bradford-White Corp MI503*F(BN.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Bradford-White Corp MI503*F(BN, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Bradford-White Corp MI503*F(BN. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Bradford-White Corp MI503*F(BN ansehen.

Die komplette Bedienungsanleitung des Geräts Bradford-White Corp MI503*F(BN, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Bradford-White Corp MI503*F(BN hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Bradford-White Corp MI503*F(BN verständlich ist.

Eine gänzliche Bedienungsanleitung von Bradford-White Corp sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Bradford-White Corp MI503*F(BN bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Bradford-White Corp MI503*F(BN befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Bradford-White Corp MI503*F(BN, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Bradford-White Corp MI503*F(BN - die uns die ersten Schritte während der Nutzung von Bradford-White Corp MI503*F(BN erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Bradford-White Corp MI503*F(BN hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Bradford-White Corp MI503*F(BN im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Bradford-White Corp MI503*F(BN?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Bradford-White Corp MI503*F(BN nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Bradford-White Corp MI503*F(BN hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)