Wayne GPB400 - page 1
Please read and save these instructions. Read carefully befor e attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury an d/or pr operty damage! Retain instructions for future refer ence. Engine D ...
-
Wayne GPB400 - page 2
2 2. Suction hose and fitting must be airtight. An air leak in the suction line MA Y prevent priming of the pump. Use of thread sealant is r ecommended. Suction lines must be reinforced hose or rigid pipe. Non-reinforced hose will collapse due to the suction created by the pump and prevent pump from operating. 3. A check valve must be used in the s ...
-
Wayne GPB400 - page 3
3 Performance Information PERFORMANCE CURVE 100 80 60 40 20 1200 2400 3600 4800 6000 7200 Capacity - GPH T otal Dynamic Head - FEET 0 2” Cast Iron Pump Performance GPB400 www .waynepumps.com CAP ACITIES IN GALLONS PER HOUR Discharge Head - Feet Dynamic Suction Lift - Feet 0 5 10 15 20 25 20 6600 6420 6180 6000 5640 5220 30 6180 6000 5640 5220 480 ...
-
Wayne GPB400 - page 4
4 1 Engine 57800-001 1 2 V olute Bracket 56724-001 1 3 Impeller kit 56711 1 4 Screw 17046-001 1 5 Key 16997-001 1 6 Shaft seal kit 56711 1 7 V olute 56723-001 1 8 Pipe plug, 3/4 NPT 15921 2 9 V olute gasket 15556-002 1 10 Cap screw , 5/16 - 18 x 1 12701 5 11 Cap screw , 5/16 - 24 x 7/8 16209 4 12 Lock washer , split 5/16 (not shown) 15916 4 13 Hand ...
-
Wayne GPB400 - page 5
5 Notes GPB400 www .waynepumps.com ...
-
Wayne GPB400 - page 6
6 Maintenance / Service Recor d Date Maintenance Performed Replacement Components Requir ed Operating Instructions and Replacement Parts List www .waynepumps.com ...
-
Wayne GPB400 - page 7
7 GPB400 www .waynepumps.com Maintenance / Service Recor d Date Maintenance Performed Replacement Components Requir ed ...
-
Wayne GPB400 - page 8
8 Limited W arranty For one year from date of purchase, WA YNE Water Systems (”W A YNE Pumps“) will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (”Product“) found upon examination by W A YNE Pumps to be defective in materials or workmanship. Please call WA YNE Pumps (800-237 ...
-
Wayne GPB400 - page 9
V euillez lire et conserver ces instructions. Lire attentivement avant d’assembler , d’installer , de faire fonctionner ou de fair e l’entretien du pr oduit décrit. Se protéger et protéger les autr es en observant tous les renseignements de sécurité. Le manquement à se conformer aux consignes pourrait avoir pour résultat des blessures ...
-
Wayne GPB400 - page 10
10 Fr 1. La pompe doit être placée aussi près que possible de l’eau à pomper . Une pompe d’une hauteur d’aspiration de 6,1 m (20 pi) n’aspirera pas l’eau aussi vite qu’une pompe d’une hauteur d’aspiration de 1,5 m (5 pi) (Figure 1). 2. Le tuyau d’aspiration et le raccord doivent être étanches. Une fuite d’air dans la condu ...
-
Wayne GPB400 - page 11
11 Fr Informations sur le Rendement PERFORMANCE CURVE 100 80 60 40 20 1200 2400 3600 4800 6000 7200 Capacity - GPH T otal Dyna m ic Head - FEET 0 Performance de la pompe en fonte 5 cm (2 po) GPB400 CAP ACITÉS EN GALLONS P AR HEURE Décharge Tête-Pied Aspiration Dynamique - Pied 0 5 10 15 20 25 20 6600 6420 6180 6000 5640 5220 30 6180 6000 5640 52 ...
-
Wayne GPB400 - page 12
12 Fr 1 Moteur 57800-001 1 2 Support de volute 56724-001 1 3 T rousse d’impulseur 56711 1 4 Vis 17046-001 1 5 Clé 16997-001 1 6 T rousse de garniture d’étanchéité de l’arbre 56711 1 7 V olute 56723-001 1 8 Bouchon de tuyau, 3/4 po. NPT 15921 2 9 Joint d’étanchéité volute 15556-002 1 10 V is à tête hexagonale, 7,9 mm (5/16 po) - 18 ...
-
Wayne GPB400 - page 13
13 Fr Remar ques GPB400 ...
-
Wayne GPB400 - page 14
14 Fr Garantie limitée Pendant un an à compter de la date d’achat, WA YNE Water System («W A YNE Pumps») réparera ou remplacera, à sa discrétion, pour l’acheteur original toute pièce ou pièces de ces pompes de puisard ou pompes à eau («Produit») déterminées défectueuses, par WA YNE Pumps, en terme de matériaux ou de fabrication. ...
-
Wayne GPB400 - page 15
Sírvase leer y guardar estas instrucciones. Lea atentamente antes de intentar armar , instalar , operar o realizar mantenimiento al producto descrito. Protéjase a usted mismo y a otros r espetando toda la información de seguridad. No respetar las instrucciones podría dar como re sultado lesiones personales y/o daño a la propiedad. Conserve est ...
-
Wayne GPB400 - page 16
16 Sp 2. La manguera y las conexiones de succión deben estar selladas herméticamente. Una fuga de aire en la línea de succión PODRÍA impedir el cebado de la bomba. Se recomienda el uso de un sellador de r osca. Las líneas de succión deben ser de manguera reforzada o tuberías rígidas. Una manguera no reforzada colapsará debido a la succió ...
-
Wayne GPB400 - page 17
17 Sp Información del r endimiento PERFORMANCE CURVE 100 80 60 40 20 1200 2400 3600 4800 6000 7200 Capacity - GPH T otal Dyna m ic Head - FEET 0 Desempeño de la bomba de hierro fundido de 5 cm (2 pulg.) GPB400 CAP ACIDADES EN GALONES POR HORA Altura de descarga, en pies Altura de succión dinámica, en pies 0 5 10 15 20 25 20 6600 6420 6180 6000 ...
-
Wayne GPB400 - page 18
18 Sp 1 Motor 57800-001 1 2 Montaje del espiral 56724-001 1 3 Juego de impulsor 56711 1 4 T ornillo 17046-001 1 5 Chaveta 16997-001 1 6 Kit del sello del eje 56711 1 7 Espiral 56723-001 1 8 T apón del tubo de 1,9 cm (3/4 pulg.) NPT 15921 2 9 Junta del difusor 15556-002 1 10 T ornillo de sombrerete, 5/16 - 18 x 1 12701 5 11 T ornillo de sombrerete, ...
-
Wayne GPB400 - page 19
19 Sp Notas GPB400 ...
-
Wayne GPB400 - page 20
20 Sp Garantía limitada Durante un (1) año a partir de la fecha de compra, WA YNE Water Systems (”W A YNE Pumps“) reparará o reemplazará, a su criterio, para el comprador original, cualquier pieza o piezas de sus Bombas para cloacas o Bombas de agua (el “Producto”) que después de un examen sea(n) hallada(s) por WA YNE Pumps como defect ...
Haben Sie eine Frage bezüglich Wayne GPB400?
Nutzen Sie das untere Formular
Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Wayne GPB400 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Wayne GPB400 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.