Bedienungsanleitung IOGear GIC704SR5W6

28 Seiten 0.82 mb
Download

Zur Seite of 28

Summary
  • IOGear GIC704SR5W6 - page 1

    1 GIC704SR5W6 P ART NO. M0560 Installation Installation Installation Guide RAID5 eSA T A 1.5Gbps 4 External port PCI Card ...

  • IOGear GIC704SR5W6 - page 2

    ...

  • IOGear GIC704SR5W6 - page 3

    3 T able of Contents Caution 4 Introduction 5 Features 6 Package Contents 7 What Is RAID? 8 Installation Procedur e 11 Software Installation 18 Federal Communications Commission (FCC) Statement 22 CE Statement 24 Limited W arranty 25 Contact 26 ...

  • IOGear GIC704SR5W6 - page 4

    4 Caution • Before installation of the contr oller card, we recommend that users study this manual fi rst. This RAID manual has more information on RAID ar chitecture, RAID features, RAID installation, RAID settings and Management software for the RAID5 GUI (Graphical User Interface). • W indows Device Manager cannot recognize har d drives wit ...

  • IOGear GIC704SR5W6 - page 5

    5 Introduction The board of fers the ability to upgrade your desktop computer to RAID 5, RAID 0+1, RAID 0, or RAID 1 as well as JBOD. The board can contr ol four independent Serial A T A channels. Each channel has its own Serial A T A bus and will support one Serial A T A device. The board supports Serial A T A Generation 1 transfer rates of 1.5 Gb ...

  • IOGear GIC704SR5W6 - page 6

    6 Features PCI Interface Compliant with PCI Speci fi cations, Revision 2.2. • Integrated PCI DMA engines. • 32 bit, 33/66MHz fully compliant PCI host interface. • High Speed Serial A T A Interface Four high speed Serial A T A interface ports, each supporting 1st generation Serial A T A data rates • (1.5Gb/s). RAID 5 (Distributed Parity RAI ...

  • IOGear GIC704SR5W6 - page 7

    7 Package Contents RAID5 SA T A-150 4Ports PCI Host Adapter • Quick Start Guide • Driver CD • ...

  • IOGear GIC704SR5W6 - page 8

    8 RAID - Redundant Array of Independent Disks RAID technology manages multiple disk drives to enhance I/O performance and provide r edundancy in order to withstand the failur e of any individual drive, without loss of data. Disk Striping (RAID 0) Striping is a performance-oriented, non-redundant data mapping technique. While Striping is discussed a ...

  • IOGear GIC704SR5W6 - page 9

    9 Mirror ed-Striping (RAID 0+1 also known as RAID 10) A Mirror ed-Striping Set does just what it says, combining both Striping and Mirroring technologies to pro- vide both the performance enhancements that come from Striping and the data availability and integrity that comes from Mirr oring. When data is written to a Mirrored-Striped Set, instead o ...

  • IOGear GIC704SR5W6 - page 10

    10 Just a Bunch of Disks (JBOD/Contiguous) JBOD (also known as Contiguous) means a logical drive that can either be an entire disk drive or a segment of a single disk drive. For this card, the JBOD function only supports one disk. JBOD her e is a Contiguous con fi guration option when using the “Create RAID Group” within the SA T ARAID5 Manage ...

  • IOGear GIC704SR5W6 - page 11

    11 1. Power down the computer system. 2. Insert the Host card into an available bus slot. 3. Power on the computer system. 4. Install drivers for the device. 5. Remove all existing SA T ARAID GUIs (or Java SA T ARAID GUIs) to ensure your new SA T ARAID5 GUI installs and functions properly . 6. Install the SA T ARAID5 GUI. 7. Power down the computer ...

  • IOGear GIC704SR5W6 - page 12

    12 11. Use the SA T ARAID5 Manager GUI to con fi gur e your RAID settings. If using 1 Disk, please select “Concatenate” or “Contiguous” settings only . If using 2 Disks, do NOT select “Parity RAID” or “Mirror ed Stripe” settings. If using 3 Disks, do NOT select the “Mirror ed Stripe” setting. 12. Open “T ask Manager” to mak ...

  • IOGear GIC704SR5W6 - page 13

    13 BIOS (RAID Settings) Creating and deleting RAID sets is a function found in the BIOS. During boot up, the RAID setting message will appear and pause for a few moments to allow the user access to its settings. The board will act as a normal NON-RAID card when the BIOS does not have it con fi gured for RAID. If you’re using traditional par alle ...

  • IOGear GIC704SR5W6 - page 14

    14 Creating Mirr ored Sets (RAID 1) 1. As the BIOS boots, Press CTRL+S or F4 to enter the RAID bios utility . 2. Select Create RAID set. Pr ess Enter . 3. Select RAID 1 then press Enter . 4. Select Auto con fi guration . Pr ess Enter . 5. Press Y to save your settings. 6. Press CTRL+E and then pr ess Y to exit the setup. 7. Continue with conventio ...

  • IOGear GIC704SR5W6 - page 15

    15 Creating a Mirr ored-Striped Set (RAID 10) 1. As the BIOS boots, press CTRL+S or F4 to enter the RAID bios utility . 2. Select Create RAID set . Pr ess F2 . 3. Select RAID 10 then press Enter . 4. Select Auto con fi guration . Pr ess Enter . 5. Press Y and then pr ess ESC to exit the setup. 7. Continue with conventional Fdisk and Format steps t ...

  • IOGear GIC704SR5W6 - page 16

    16 Creating JBOD Sets 1. As the BIOS boots, Press CTRL+S or F4 to enter the RAID bios utility . 2. Select Create RAID set . Pr ess Enter . 3. Select JBOD (Single) then press Enter . 4. Select JBOD Drives . Press Enter . 5. Select RAID size . Press Enter . 6. Press Y to save your settings. Creating Spar e Drive 1. As the BIOS boots, Press CTRL+S or ...

  • IOGear GIC704SR5W6 - page 17

    17 Deleting RAID Sets 1. As the BIOS boots, Press CTRL+S or F4 to enter the RAID bios utility . 2. Select Delete RAID set . Press Enter . 3. Answer Y to remove the RAID set. If the RAID set being deleted is a Striped, then all of the data will be lost. If the set being deleted is a Mirror ed set, then the data will remain intact and accessible on b ...

  • IOGear GIC704SR5W6 - page 18

    18 Windows XP Fresh Installation 1. Power off the system. Insert the contr oller card into a PCI slot and connect the hard drives to the controller car d. Power up the system. 2. Put your Windows XP CD into the CD-ROM/DVD drive. 3. Press F6 for thir d party SCSI or driver installation. Press ‘S’ when setup asks if you want to specify an additio ...

  • IOGear GIC704SR5W6 - page 19

    19 Windows XP Existing Installation 1. Power off the system. Insert the contr oller card into a PCI slot and connect the hard drives to the control- ler card. Power up the system. 2. During OS boot up, Windows will display the ‘Found New Hardware Wizard’ . Click ‘Next’ . 3. Select ‘Install from a list or speci fi c location (Advanced)’ ...

  • IOGear GIC704SR5W6 - page 20

    20 4. Insert the Driver CD in your CD-ROM/DVD drive, check Specify a location , uncheck the other boxes, click Next , type in your CD-ROM/DVD Drive Letter and Click Browse . 5. Specify the following location: [CD Drive Letter]:RAID5 SA T A_4PortSiI3114W in XP_2000_2003Driver . Select Open then click OK . 6. When the wizard indicates that it fou ...

  • IOGear GIC704SR5W6 - page 21

    21 V erifying controller installation 1. Right click on the ‘My Computer’ icon and select ‘Properties’ . Left click on the ‘Har dware’ tab then select the ‘Device Manager’ button. 2. Double click on ‘SCSI and RAID Controllers’ , If ther e is no yellow ‘!’ or ‘?’ in front of the ‘Silicon Image SiI 3114 SoftRAID5 Control ...

  • IOGear GIC704SR5W6 - page 22

    22 Federal Communications Commission (FCC) Statement Federal Communications Commission (FCC) Statement 15.21 Y ou are cautioned that changes or modi fi cations not expressly approved by the part r esponsible for compliance could void the user’ s authority to operate the equipment. 15.105(b) This equipment has been tested and found to comply with ...

  • IOGear GIC704SR5W6 - page 23

    23 - Connect the equipment into an outlet on a circuit dif ferent from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. THIS DEVICE COMPLIES WITH P ART 15 OF THE FCC RULES. OPERA TION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: 1. this device may not cause interference and 2. this device ...

  • IOGear GIC704SR5W6 - page 24

    24 This device has been tested and found to comply with the requir ements set up in the council directive on the approximation of the law of member states r elating to EMC Directive 89/336/EEC, Low V oltage Directive 73/23/EEC and R&TTE Directive 99/5/EC. CE Statement ...

  • IOGear GIC704SR5W6 - page 25

    25 The manufacturer , IOGEAR, makes NO warranty or repr esentation, whether express or implied, regar ding the contents, use or suitability of this software, disk or documentation. IOGEAR speci fi cally disclaims any and all warranties regar ding the quality and performance of this software, disk or documentation including, but not limited to the ...

  • IOGear GIC704SR5W6 - page 26

    26 Contact T oll Free: (866) 9-IOGEAR Phone: (949) 453-8782 23 Hubble Irvine, CA 92618 USA www .iogear .com support@iogear .com ©2007 IOGEAR. All Rights Reserved. P ART NO. M0560 IOGEAR, the IOGEAR logo, MiniView , VSE are trademarks or registered trademarks of IOGEAR, Inc. Micr osoft and W indows are register ed trademarks of Microsoft Corporatio ...

  • IOGear GIC704SR5W6 - page 27

    27 ...

  • IOGear GIC704SR5W6 - page 28

    © 2007 IOGEAR, INC. FUN IOGEAR offers connectivity solutions that ar e innovative, fun, and stylish, helping people enjoy daily life using our high technology products. GREEN IOGEAR is an environmentally conscious company that emphasizes the importance of conserving natural resour ces. The use of our technology solu tions helps reduce electr onic ...

Produzent IOGear Kategorie Computer Hardware

Dokumente, die wir vom Produzenten des Geräts IOGear GIC704SR5W6 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen IOGear
- Bedienungsanleitungen GIC704SR5W6
- Produktkarten IOGear
- Informationsbroschüren
- oder Energieetiketten IOGear GIC704SR5W6
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung IOGear GIC704SR5W6.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen IOGear GIC704SR5W6, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen IOGear GIC704SR5W6. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts IOGear GIC704SR5W6 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts IOGear GIC704SR5W6, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von IOGear GIC704SR5W6 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von IOGear GIC704SR5W6 verständlich ist.

Eine gänzliche Bedienungsanleitung von IOGear sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von IOGear GIC704SR5W6 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von IOGear GIC704SR5W6 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich IOGear GIC704SR5W6, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts IOGear GIC704SR5W6 - die uns die ersten Schritte während der Nutzung von IOGear GIC704SR5W6 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit IOGear GIC704SR5W6 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von IOGear GIC704SR5W6 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich IOGear GIC704SR5W6?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit IOGear GIC704SR5W6 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit IOGear GIC704SR5W6 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)