    Elec tronic/Me chanic al ermos tat Mo del 40170 installation and operation manual 42998-01 01-19-2007 ...

  • Hunter Fan 40170 - page 2

    2 ...

  • Hunter Fan 40170 - page 3

    3 T able of Contents Important Information.................................................. 5 T ools ............................................................................ 6 Uninstalling the Existing Unit ...................................... 9 Installing the Thermostat ........................................... 13 installing the wall plat ...

  • Hunter Fan 40170 - page 4

    4 Congratulations! T hank you for choosing a Hunter thermostat. Y our new Hunter thermostat will provide years of reliable service and year -round energy savings . Please read this manual before beginning installation and save this booklet for complete operation instructions . Electronic/Mechanical Thermostat Model 40170 ...

  • Hunter Fan 40170 - page 5

    5 T his thermostat is designed to work on the following heating and cooling systems: Gas – Standing Pilot Gas – Electronic Ignition Gas – F ired Boilers Gas – Millivolt Systems Oil – F ired Boilers Oil – F ired Furnace Electric Furnace Electric Air Conditioning Single-stage Heat Pump Systems T his thermostat is not designed for Multi-st ...

  • Hunter Fan 40170 - page 6

    6 T his thermostat includes two #8 slotted screws and two wall anchors for mounting. T o install your new thermostat, you will need the following supplies: Flat-head screwdriver ............................................................................................. Small Phillips-head screwdriver .............................................. ...

  • Hunter Fan 40170 - page 7

    7 NO TICE! Do not disconnect the wires from the existing thermostat befor e reading these instructions . The wires must be labeled prior to removal to ensure pr oper reconnection. ...

  • Hunter Fan 40170 - page 8

    8 UNINST ALLING THE EXISTING UNIT Y RC G W Y RC G W ...

  • Hunter Fan 40170 - page 9

    9 1. T urn the system power OFF from the existing thermostat. T urn the power to the HV AC system OFF at the main power panel or at the furnace . 2. Remove the existing thermostat cover to access the wires from the wall. (Some thermostats may have multiple covers , screws or other locking devices that must be removed or disengaged.) 3. Locate , but ...

  • Hunter Fan 40170 - page 10

    10 UNINST ALLING THE EXISTING UNIT , CONT . if your existing thermostat is marked... label the wire with this sticker: G / F G G W / H W W Y / C* / M Y Y RC / V C RC RC RH / R / VR / 4 RH RH 24 V olt 24 V olt cool air conditioning compressor heating fan O O O reversing valve cool B B B reversing valve heat ...

  • Hunter Fan 40170 - page 11

    11 4. Using the provided stick ers , label each wire according to the chart. (If the terminals are not labeled, contact a qualified HV AC technician.) Note: Wire colors do not always comply with standards, so wire color should be ignored. Refer to the existing terminal designation for proper identification. *If wires mark ed Y & C are both pr ...

  • Hunter Fan 40170 - page 12

    12 T op Cover T hermostat ...

  • Hunter Fan 40170 - page 13

    13 INST ALLING THE THERMOST A T INST ALLING THE THERMOST A T 1. Remove the top cover from the new thermostat by pulling the two halves apart. ...

  • Hunter Fan 40170 - page 14

    14 ...

  • Hunter Fan 40170 - page 15

    15 2. P osition the new thermostat on the w all and pull the labeled wires through the opening. 3. If the existing holes do not match those on the Hunter wall plate , or if there are no existing holes , level the thermostat and mark the wall for two holes . 4. Remove the thermostat and drill two 3/16” holes where mark ed. 5. T ap the plastic anch ...

  • Hunter Fan 40170 - page 16

    16 INST ALLING THE THERMOST A T , CONT . G RC RH Y W B O R H R C W G B O Y ...

  • Hunter Fan 40170 - page 17

    17 INST ALLING THE THERMOST A T , CONT . CONNECTING THE WIRES 1. Loosen, but do not remove , the terminal screws . Note: A jumper wire has been provided, connecting the RC and RH terminals for systems that do not provide both an RH and RC wire. If you have both an RH and RC wire, remove this jumper . If you do not have both an RH and RC wire, leave ...

  • Hunter Fan 40170 - page 18

    18 INST ALLING THE THERMOST A T , CONT . HG HE HP STD HE/HG Switch HP/STD Switch ...

  • Hunter Fan 40170 - page 19

    19 A TT ACHING THE THERMOST A T 1. Locate the HE/HG switch on the wall plate . Set the switch to HG for a gas furnace or oil burner . Set the switch to HE for electric furnaces . (T he switch has no effect when the system is set to cooling mode .) 2. Locate the HP/STD switch on the wall plate . Set the switch to HP for Single-stage heat pump system ...

  • Hunter Fan 40170 - page 20

    20 INST ALLING THE THERMOST A T , CONT . ...

  • Hunter Fan 40170 - page 21

    21 3. Insert two fresh AA alkaline batteries. 4. Align the top cover with the the wall plate , and snap the two halves together . 5. Restore power at the electrical panel or furnace . INST ALLING THE THERMOST A T , CONT . ...

  • Hunter Fan 40170 - page 22

    22 AUTO ON C OOL OFF HEAT SYSTEM 9 0 0 7 0 6 0 5 8 0 F an Switch System Switch Set T emperature Slider ...

  • Hunter Fan 40170 - page 23

    23 OPERA TION 1. Set the Set Temperature slider to the desired temperature . 2. T he System Switch determines the operating mode of the thermostat. Select Cool, Off, or Heat. 3. T he Fan Switch should normally be located in the Auto position. T o run the fan continuously , slide the Fan Switch to the On position. Note: In Auto , The fan will be tur ...

  • Hunter Fan 40170 - page 24

    24 INDICA TORS AND ADUSTMENT 0 5 0 6 0 7 8 0 9 0 T hermometer Battery Indicator ...

  • Hunter Fan 40170 - page 25

    25 INDICA TORS AND ADUSTMENT 1. T he Thermometer indicates the room temperature . 2. T he Battery Indicator displays two battery conditions . The first w arning is the Weak Battery Warning , indicated by the Battery Indicator flashing once approximately every three seconds . When this warning appears , install two fresh AA alkaline batteries at y ...

  • Hunter Fan 40170 - page 26

    26 SP AN Span Adjust SP AN ...

  • Hunter Fan 40170 - page 27

    27 INDICA TORS AND ADJUSTMENTS, CONT . 1. Remove the top cover from the thermostat. 2. T o make your system run LONGER, turn the Span Adjust clockwise . 3. T o mak e your system run SHOR TER, turn the Span Adjust counter clockwise . 4. Reattach the top cover to the thermostat. Note: The Span range is 0.6 o F - 3 o F . The Span setting remains the s ...

  • Hunter Fan 40170 - page 28

    28 1. My heating or cooling will not turn on or off . 1 a. Check the HE/HG switch to ensure it is set to the correct position. 1 b . Wait. T here may be as much as a 4-minute delay before the system turns on or off to protect the compressor . 1 c. Check the circuit breakers and switches to ensure there is enough power to the system. 1 d. Replace th ...

  • Hunter Fan 40170 - page 29

    ...

  • Hunter Fan 40170 - page 30

    30 G Rc Rh W Y F an Relay Heat/Cool 24V Supply Cool Contactor Heat Relay or V alve X Jumper 4-wire Heat/Cool System G Rc Rh F an Relay Heat 24V Supply W Heat Relay or V alve Y Cool Contactor 5-wire Heat/Cool System Cool 24V Supply ...

  • Hunter Fan 40170 - page 31

    31 WIRING DIAGRAMS Reversing Valv e Compressor Contactor X Fan Relay Heat/Cool 24V Supply Single-stage Heat Pump System Cool Mode Heat Mode OR W G Rc Rh O B Y X Jumper Rc Rh W Heat 24V or Millivolt Supply Heat Relay or V alve X Jumper 2-wire Heat Only System ...

  • Hunter Fan 40170 - page 32

    32 G Rc Rh W Heat 24V Supply Heat Relay or V alve X Jumper 3-wire Heat Only System Fan Relay G Rc Rh W Heat 24V Supply Heat Relay or V alve X Jumper 3-wire Heat Only System Fan Relay G Rc Rh Y Cool Contacter Cool 24V Supply X Jumper 3-wire Cool Only System F an Relay G Rc Rh Y Cool Contacter Cool 24V Supply X Jumper 3-wire Cool Only System F an Rel ...

  • Hunter Fan 40170 - page 33

    33 © 2007 Hunter F an Company ...

Produzent Hunter Fan Kategorie Thermostat

Dokumente, die wir vom Produzenten des Geräts Hunter Fan 40170 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Hunter Fan
- Bedienungsanleitungen 40170
- Produktkarten Hunter Fan
- Informationsbroschüren
- oder Energieetiketten Hunter Fan 40170
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Hunter Fan 40170.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Hunter Fan 40170, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Hunter Fan 40170. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Hunter Fan 40170 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Hunter Fan 40170, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Hunter Fan 40170 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Hunter Fan 40170 verständlich ist.

Eine gänzliche Bedienungsanleitung von Hunter Fan sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Hunter Fan 40170 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Hunter Fan 40170 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Hunter Fan 40170, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Hunter Fan 40170 - die uns die ersten Schritte während der Nutzung von Hunter Fan 40170 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Hunter Fan 40170 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Hunter Fan 40170 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Hunter Fan 40170?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Hunter Fan 40170 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Hunter Fan 40170 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)