Bedienungsanleitung Paradyne SLV 9128

19 Seiten 0.07 mb
Download

Zur Seite of 19

Summary
  • Paradyne SLV 9128 - page 1

    1 FrameSaver R SL V 9128 Quick Reference Document Number 9128-A2-GL10-40 May 2000 Product Documentation on the W orld Wide W eb We provide complete product documentation online. This lets you search the documentation for specific topics and print only what you need, reducing the waste of surplus printing. It also helps us maintain competitive price ...

  • Paradyne SLV 9128 - page 2

    2 00-16722a Menu Hierar ch y Status System and T est Status LMI Reported DLCIs PVC Connection Status Timeslot Assignment Status DBM Interface Status IP Routing T able Perf ormance Statistics T rap Event Log Display LEDs and Control Leads Identity Identity • System • NAM • DBM LMI Reported DLCIs • DLCI • Status • CIR (bps) PVC Connection ...

  • Paradyne SLV 9128 - page 3

    3 MAIN MENU Status T est Configuration Auto-Configur ation Control Easy Install Auto-Configuration • Fr ame Relay Discov ery Mode • Automatic Circuit Remov al • Automatic Backup Configuration 00-16728b MAIN MENU Status T est Configuration Auto-Configuration Control Easy Install System Information • Device Name • System Name, Location, Con ...

  • Paradyne SLV 9128 - page 4

    4 Configuration Option Summaries This section summarizes the configuration options accessed when you select Configuration from the Main Menu. H System H Physical (Network, Data Port, and ISDN) H ISDN (Link Profiles) H DSX-1 H T ime Slot Assignment — Frame Relay Network Assignments — DSX-1 to Network Assignments — Sync Data Port Assignments H ...

  • Paradyne SLV 9128 - page 5

    5 Frame Relay and LMI Select Frame Relay and LMI to configure the general frame relay options for the system. Frame Relay and LMI Configuration Option Settings Default in [ Bold ] LMI Behavior [ Independent ], Port-1_Follows_Net1-FR1, Port-2_Follows_Net1-FR1, All_Ports_Follow_Net1-FR1 Net1-FR1_Follows_Port-1, Net1-FR1_Follows_Port-2, Port-1_Codepen ...

  • Paradyne SLV 9128 - page 6

    6 General Select General to configure a timeout period and duration for user-initiated loopbacks and pattern tests, a primary and secondary clock source for the system, and a system alarm relay . General Configuration Option Settings Default in [ Bold ] T est T imeout [ Enable ], Disable T est Duration (min) 1 – 120 [ 10 ] Primary Clock Source [ ...

  • Paradyne SLV 9128 - page 7

    7 Data Ports Select Data Ports, then Physical to configure physical characteristics for the port connected to the DTE. Data Ports Configuration Option Settings Default in [ Bold ] Port Status [ Enable ], Disable Port Use (Port-2 only) [ Frame Relay ], Synchronous Data For Port-1 or when Port Use is set to Frame Relay on Port-2: Max Port Rate (Kbps) ...

  • Paradyne SLV 9128 - page 8

    8 ISDN Select ISDN, then Physical to configure physical characteristics for the ISDN interface if an ISDN DBM is installed. The following table shows the configuration options for an ISDN BRI DBM. ISDN BRI Configuration Option Settings Default in [ Bold ] Interface Status Enable, [ Disable ] Originate or Answer [ Originate ], Answer Service Profile ...

  • Paradyne SLV 9128 - page 9

    9 ISDN Link Profiles Select ISDN, then Link Profiles to configure the ISDN Link Profiles. Link Profiles Configuration Option Settings Default in [ Bold ] Link Name ASCII text entry , [ HQ_Site ] Link Status Auto, [ Disable ] Outbound Phone Number 0 – 9, * , # , <space>, _ , – , ), or ( Inbound Calling ID 1 or 2 0 – 9 Maximum Link Rate ( ...

  • Paradyne SLV 9128 - page 10

    10 Time Slot Assignment Select T ime Slot Assignment to make cross-connection assignments. Select Frame Relay Network Assignments to assign DS0s on the T1 network interface(s) for frame relay links. Frame Relay-to-Network Interface Time Slot Assignment Network Channel Settings Default in [ Bold ] T ime Slot Discovery [ Enable ], Disable N0 1 – N2 ...

  • Paradyne SLV 9128 - page 11

    11 Frame Relay Select Frame Relay to configure the Frame Relay characteristics of the following interfaces: H Network H Data Ports Frame Relay Configuration Option Settings Default in [ Bold ] LMI Protocol lnitialize_From_Net1FR1, Initialize_From_Interface, Auto_On_LMI_Fail, Standard, Annex-A, Annex-D [ lnitialize_From_Interface ] for a data port l ...

  • Paradyne SLV 9128 - page 12

    12 DLCI Records Select DLCI Records to manually configure DLCI records for each interface. The Auto-Configuration feature provides automatic configuration of DLCI records. Select DLCI Records to configure the DLCI Records for the following interfaces: H Network H Data Port H ISDN The Auto-Configuration feature provides automatic DLCI record configu ...

  • Paradyne SLV 9128 - page 13

    13 PVC Connections Select PVC Connections to manually configure the logical connections between the selected interface and the data ports. The Auto-Configuration feature provides automatic configuration of PVC connections. PVC Connections Configuration Option Settings Default in [ Bold ] Source Link Port- n , ISDN Link Name , Net1-FR1 Source DLCI 1 ...

  • Paradyne SLV 9128 - page 14

    14 Node IP Select Node IP to configure support of the IP communication network. Node IP Configuration Option Settings Default in [ Bold ] Node IP Address 001.000.000.000 – 223.255.255.255, [ Clear ] Node Subnet Mask [ 000.000.000.000 ] – 255.255.255.255, Clear Default IP Destination [ None ], Modem, COM, PVCname TS Access Management Link [ None ...

  • Paradyne SLV 9128 - page 15

    15 General SNMP Management Select General SNMP Management to configure the FrameSaver unit so it can be managed as an SNMP agent. General SNMP Management Configuration Option Settings Default in [ Bold ] SNMP Management [ Enable ], Disable Community Name 1 A SC II text entry , [ Public ], Clear Name 1 Access Read, [ Read/W rite ] Community Name 2 A ...

  • Paradyne SLV 9128 - page 16

    16 SNMP NMS Security Select SNMP NMS Security to configure access to the unit. SNMP NMS Security Configuration Option Settings Default in [ Bold ] NMS IP V alidation Enable, [ Disable ] Number of Managers [ 1 ] – 10 NMS n IP Address 001.000.000.000 – 223.255.255.255, [ Clear ] Access T ype [ Read ], Read/Write SNMP T raps Select SNMP T raps to ...

  • Paradyne SLV 9128 - page 17

    17 Communication Port Select Communication Port to configure the FrameSaver unit ’ s COM port. Communication Port Configuration Option Settings Default in [ Bold ] Port Use [ T erminal ], Net Link When Port Use is set to T erminal: Data Rate (Kbps) 9.6, 14.4, [ 19.2 ], 28.8, 38.4, 57.6, 1 15.2 Character Length 7, [ 8 ] Parity [ None ], Even, Odd ...

  • Paradyne SLV 9128 - page 18

    18 Modem Port Select Modem Port to configure the FrameSaver unit ’ s Modem port. Modem Port Configuration Option Settings Default in [ Bold ] Port Use [ T erminal ], Net Link When Port Use is set to T erminal: Dial-In Access [ Enable ], Disable Login Required Enable, [ Disable ] Port Access Level [ Level-1 ], Level-2, Level-3 Inactivity T imeout ...

  • Paradyne SLV 9128 - page 19

    19 W arranty , Sales, Service, and T raining Information Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty , sales, service, repair , installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one ...

Produzent Paradyne Kategorie Network Hardware

Dokumente, die wir vom Produzenten des Geräts Paradyne SLV 9128 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Paradyne
- Bedienungsanleitungen SLV 9128
- Produktkarten Paradyne
- Informationsbroschüren
- oder Energieetiketten Paradyne SLV 9128
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Paradyne SLV 9128.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Paradyne SLV 9128, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Paradyne SLV 9128. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Paradyne SLV 9128 ansehen.

Die komplette Bedienungsanleitung des Geräts Paradyne SLV 9128, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Paradyne SLV 9128 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Paradyne SLV 9128 verständlich ist.

Eine gänzliche Bedienungsanleitung von Paradyne sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Paradyne SLV 9128 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Paradyne SLV 9128 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Paradyne SLV 9128, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Paradyne SLV 9128 - die uns die ersten Schritte während der Nutzung von Paradyne SLV 9128 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Paradyne SLV 9128 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Paradyne SLV 9128 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Paradyne SLV 9128?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Paradyne SLV 9128 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Paradyne SLV 9128 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)