Bedienungsanleitung Zephyr AK7836ASX

19 Seiten 0.61 mb
Download

Zur Seite of 19

Summary
  • Zephyr AK7836ASX - page 1

    Use, Care, and Installation Guide www .zephyronline.com Model number: Serial Number: Date of Purchase: Sales Dealer: AUG08.0101 © Zephyr Corporation Cypress AK7836ASX AK7842ASX AK7848ASX READ AND SA VE THESE INSTRUCTIONS INTENDED FOR OUTDOOR COVERED P A TIO OR LANAI AREA. ...

  • Zephyr AK7836ASX - page 2

    www .zephyronline.com ...

  • Zephyr AK7836ASX - page 3

    1 SAFETY NOTICE ................................................................. 2-3 LIST OF MA TERIALS ....................................................... 4 INST ALLA TION Ducting Calculation Sheet ....................................... 5 Mounting Height & Clearance ................................ 6 Ducting Options ..................... ...

  • Zephyr AK7836ASX - page 4

    Important Safety Notice READ AND SA VE THESE INSTRUCTIONS 2 www .zephyronline.com W ARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS F AN WITH ANY SOLID-ST A TE CONTROL DEVICE. W ARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSER VE THE FOLLOWING: a. Use this unit only in the manner intended by the man ...

  • Zephyr AK7836ASX - page 5

    Important Safety Notice 3 W ARNING TO REDUCE THE RISK OF FIRE, USE ONL Y MET AL DUCTWORK. CAUTION T o reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. OPERA TION Always leave safety grilles and fi lters in place. Without these components, operat ...

  • Zephyr AK7836ASX - page 6

    List of Materials 4 www .zephyronline.com MODELS: AK7836ASX, AK7842ASX, AK7848ASX P ARTS SUPPLIED 1 - Hood 3 - Baf fl e fi lters (4 for AK7848ASX) 2 - Halogen light bulbs (3 for AK7548ASX) ( pre-installed ) 1 - 10” round transition adapter ( for dual internal and external blowers ) 1 - External blower wiring ( for external and in-line blower ) ...

  • Zephyr AK7836ASX - page 7

    5 Installation – Ducting Calculation Sheet Duct pieces To t a l Equivalent number length x used = 3-1/ 4” x 10” Rect., straight 1 Ft . x ( ) = Ft. 7”-10” Round, straight 1 Ft . x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 elb ow 15 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect. 45 0 elb ow 9 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 flat elb ow ...

  • Zephyr AK7836ASX - page 8

    Installation – Mounting Height & Clearance 6 www .zephyronline.com DUCTING A minimum of 6” round or 3-1/4” x 10” rectangular duct must be used to maintain maximum air fl ow ef fi ciency for single blower and 10” round duct for dual, in-line, and external blowers. Always use rigid type metal ducts only . Flexible ducts could restrict ...

  • Zephyr AK7836ASX - page 9

    7 W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only . Fasten all connections with sheet metal screws and tape all joints with certi fi ed Silver T ape or Duct T ape. Some Ducting Options Installation ? ...

  • Zephyr AK7836ASX - page 10

    8 www .zephyronline.com Installation – Speci fi cations 35 15/16 ” (36”) 41 15/16 ” (42”) 47 15/16 ” (48”) 12” *10 ” 27” 4” 18” 1 1/8 ” 8 9/16 ” 13 3/16 ” 2 5/16 ” 6 7/16 ” 2” 2 1/16 ” C L 5 9/16” ext blwr k/o elec k/o 2 11 / 1 6 ” top side front 4 5/16 ” *10” transition used with dual, external and in ...

  • Zephyr AK7836ASX - page 11

    9 ELECTRICAL W ARNING All Electrical work must by performed by quali fi ed electrician or person with similar technical know how and background. For personal safety , remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing ...

  • Zephyr AK7836ASX - page 12

    10 www .zephyronline.com C/L C/L A B 12 3/8 ” min 30” 4” wood board fig. 2 fig. 1 Installation – Mounting the Range Hood 1. Measure distance from range top to hood bottom ( 30” min ) Level and mark line A. 2. Plum and mark center line. 3. Mark mounting height line B. ( 12 3/8” from line A ) ( This is the top of the board used to hang th ...

  • Zephyr AK7836ASX - page 13

    11 CBI-600B AND PBI-1 100A BLOWER INST ALLA TION 1. Position blower plate over bracket on inside back of hood and pivot up. Secure plate to hood with (2) 10x3/16” screws. (blower pictured is a PBI-1 100A) 2. Connect male end of blower wire to female plug in the hood. (plug is located inside the hood behind the control panel) 3. Single Blower – ...

  • Zephyr AK7836ASX - page 14

    12 www .zephyronline.com Installation – Remote Blower Preparation 1. Place 10” round adapter on top of hood and secure with (4) M4x8 screws. Connect 10” round duct work to 10” round adapter . 2. Install threaded end of external blower wiring through external blower wiring knock out located inside the hood. 3. Place cap over threaded end of ...

  • Zephyr AK7836ASX - page 15

    13 Light On/Off By pressing , the light is switched On and Off. is on, is off. Blower Speed Selection The 2 speed levels are selected by switching to for level one and for level two. Lights On/Off Adjust Blower Level (2 Speeds) 1 1 2 2 Switching the rocker switch to middle will turn off the blower. Features & Controls – Rocker Switch Controls ...

  • Zephyr AK7836ASX - page 16

    14 www .zephyronline.com SURF ACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface. Do not use products containing chlorine bleach or orange cleaners. For heavier soil use liquid degreaser . After cleaning, you m ...

  • Zephyr AK7836ASX - page 17

    15 REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. T ouching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out. I ...

  • Zephyr AK7836ASX - page 18

    T roubleshooting 16 www .zephyronline.com TROUBLESHOOTING PROCEDURES FOR CYPRESS Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly . 2. Check the power co ...

  • Zephyr AK7836ASX - page 19

    17 DESCRIPTION P ART # Replacement Parts Light Bulb MR16 (GU10) 35W (each) Z0B-0023 Baf fl e Filter (each) 50210009 Optional Accessories Single Internal Blower CBI-600B Dual Internal Blower PBI-1 100A External Blower CBE-1000 In-Line Blower PBN-1000A Vinyl Cover (36”) AK0636AB Vinyl Cover (42”) AK0642AB Vinyl Cover (48”) AK0648AB 12” Duct ...

Produzent Zephyr Kategorie Ventilation Hood

Dokumente, die wir vom Produzenten des Geräts Zephyr AK7836ASX erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Zephyr
- Bedienungsanleitungen AK7836ASX
- Produktkarten Zephyr
- Informationsbroschüren
- oder Energieetiketten Zephyr AK7836ASX
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Zephyr AK7836ASX.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Zephyr AK7836ASX, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Zephyr AK7836ASX. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Zephyr AK7836ASX ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Zephyr AK7836ASX, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Zephyr AK7836ASX hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Zephyr AK7836ASX verständlich ist.

Eine gänzliche Bedienungsanleitung von Zephyr sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Zephyr AK7836ASX bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Zephyr AK7836ASX befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Zephyr AK7836ASX, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Zephyr AK7836ASX - die uns die ersten Schritte während der Nutzung von Zephyr AK7836ASX erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Zephyr AK7836ASX hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Zephyr AK7836ASX im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Zephyr AK7836ASX?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Zephyr AK7836ASX nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Zephyr AK7836ASX hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)